For more information, please visit the product page. date 08/28/2012 page 1 of 6 SERIES: VSUP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY RoHS (Vdc) VSUP-1K2-09 9 VSUP-1K2-12 12 VSUP-1K2-15 15 VSUP-1K2-18 18 VSUP-1K2-30 VSUP-1K2-60 ripple and noise2 efficiency max (A) max (W) max (mVp-p) typ (%) 133 1,200 90 83 100 1,200 120 84 80 1,200 150 85 66.6 1,200 150 85 24 50 1,200 150 88 30 40 1,200 150 88 36 33.3 1,200 150 88 48 24 1,200 150 89 60 20 1,200 150 90 O VSUP-1K2-36 1. output voltage is measured at output power connector 2. ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel IS C Notes: output power N VSUP-1K2-24 VSUP-1K2-48 output current TI output voltage1 MODEL U up to 1,200 W continuous power universal input (110~264 Vac) single output from 9~60 V programmable output voltage active power correction (98%) current sharing capable power good, remote sense, remote on/off control built-in DC fan over load, over voltage, over temperature, and short circuit protections UL and TUV safety approvals efficiency up to 90% N • • • • • • • • • • • ED FEATURES PART NUMBER KEY VSUP-1K2 - XX Base Number D Output Voltage cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSUP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 2 of 6 INPUT conditions/description min max units voltage 9V 12, 15, 18, 24, 30, 36, 48, 60 180 110 264 264 Vac VAc 47 63 Hz frequency current at 115 Vac at 230 Vac inrush current at 230 Vac, cold start power factor correction at 230 Vac, full load temperature coefficient 0 ~ 50°C A A 120 A min typ U conditions/description 14 7 0.98 OUTPUT parameter typ ED parameter max ±0.04 units %/°C hold-up time 230 Vac at full load adjustability adjustable with built-in trim pot programming output voltage programmable through external 1 ~ 5 V control voltage on VCI. remote sense Designated as (VS+) and (VS-). Total voltage compensation from cable losses with respect to the main output. remote inhibit Designated as (INH), requires a low signal to inhibit the output. current sharing Designated as (PAR), use in parallel for forced current sharing function. N 20 TI PROTECTION conditions/description min over voltage protection variable “OVP” follows adjustable DC output 110 over current protection1 current limiting 3 times with auto recovery before shutdown % max units 135 % 1. Protection mode sends a pulse, waits 1.5 seconds, sends second pulse, waits 3 seconds, sends third pulse, waits 5 seconds. If overload is still present, the unit will shutdown. O Notes: % 100 typ ms N parameter 12 ±5 SAFETY & COMPLIANCE parameter safety approvals min typ max units 7.0 mA max units UL/cUL 1950, TUV EN 60950 EN 55022, EN 61000-4-(2,3,4,5,6,8,11), EN 61000-3-(2,3), ENV50204 IS C EMI/EMC conditions/description leakage current at 240 Vac RoHS compliant yes ENVIRONMENTAL parameter conditions/description min operating temperature typ 0 50 °C storage temperature -20 85 °C operating humidity 20 90 % D storage humidity vibration for 60 minutes, each axis cui.com 10 95 % 10 200 Hz For more information, please visit the product page. CUI Inc │ SERIES: VSUP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 3 of 6 ≈ 80 60 50 40 ≈ U 20 10 20 30 40 50 60 70 TI N Ambient Temperature (°C) N 0 O -25 D IS C Load (%) 100 ED DERATING CURVES cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSUP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 4 of 6 MECHANICAL parameter conditions/description min typ weight 10.98 x 7.99 x 2.5 (279 x 203 x 63.5 mm) O N TI N U units: mm[inch] tolerance: ±1.0mm unless otherwise specified IS C units Kg inch MECHANICAL DRAWING D max ED dimensions 3.8 LOGIC CONNECTOR 1 VCI command input voltage for output programming 2 REF 5 Vdc reference output, can be used to derive VCI 3 PG power good signal 4 GND return / output ground 5 INH inhibit / remote on-off 6 PAR current sharing / parallel function 1 VS+ output voltage remote sense+ 2 VS- output voltage remote sense- REMOTE SENSE cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSUP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 5 of 6 TI N U ED LOGIC CONNECTIONS D IS C O N 1KΩ cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSUP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 6 of 6 REVISION HISTORY description date 1.0 initial release 02/07/2007 1.01 new template applied, V-Infinity branding removed ED rev. 08/28/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.