Datasheet

For more information, please visit the product page.
date
08/28/2012
page
1 of 6
SERIES: VSCP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY
RoHS
(Vdc)
5
9
VSCP-1K2-12
12
VSCP-1K2-15
15
VSCP-1K2-18
VSCP-1K2-24
VSCP-1K2-48
VSCP-1K2-60
efficiency
max
(W)
max
(mVp-p)
typ
(%)
1,000
50
78
88 / 133
1,200
90
83
66 / 100
1,200
120
84
53 / 80
1,200
150
85
18
44 / 66.6
1,200
150
85
24
33 / 50
1,200
150
88
36
22 / 33.3
1,200
150
88
48
16 / 24
1,200
150
89
60
13 / 20
1,200
150
90
1. output voltage is measured at output power connector
2. maximum current is measured at 100 ~ 120 V input / 200 ~ 240 V input
3. ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel
IS
C
Notes:
ripple
and noise3
160 / 200
O
VSCP-1K2-36
output
power
max
(A)
N
VSCP-1K2-05
VSCP-1K2-09
output
current2
TI
output
voltage1
MODEL
U
up to 1,200 W continuous power
universal input (90~260 Vac / 130~370 Vdc)
single output from 5~60 V
programmable output voltage
active power correction (98%)
current sharing capable
power good, remote sense, remote on/off control
built-in DC fan
over load, over voltage, over temperature, and short circuit protections
UL and TUV safety approvals
efficiency up to 90%
N
•
•
•
•
•
•
•
•
•
•
•
ED
FEATURES
PART NUMBER KEY
VSCP-1K2 - XX
Base Number
D
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 2 of 6
INPUT
conditions/description
min
voltage
frequency
current
at 230 Vac
inrush current
at 230 Vac, cold start
power factor correction
at 230 Vac, full load
max
units
90
130
260
370
Vac
Vdc
47
63
Hz
conditions/description
0 ~ 50°C
at 230 Vac, full load
A
A
min
typ
max
±0.04
U
temperature coefficient
hold-up time
7
120
0.98
OUTPUT
parameter
typ
ED
parameter
%/°C
12
ms
+3
%
100
%
adjustable with built-in trim pot
programming
output voltage programmable through external
1 ~ 5 V control voltage on VCI. Control voltage
can also be obtained from VCO via a 470 KΩ pot.
see application diagrams
remote sense
Designated as (VS+) and (VS-). Total voltage compensation from cable losses with respect to the main
output.
remote inhibit
Designated as (INH), requires a low signal to inhibit the output.
current sharing
Designated as (PAR), use in parallel for forced current sharing function.
N
adjustability
25
TI
PROTECTION
parameter
conditions/description
min
N
over voltage protection
typ
110
max
units
135
%
current limiting 3 times with auto recovery before
shutdown
over current protection1
1. Protection mode sends a pulse, waits 1.5 seconds, sends second pulse, waits 3 seconds, sends third pulse, waits 5 seconds. If overload is still present, the unit will
shutdown.
O
Notes:
-12
units
SAFETY & COMPLIANCE
parameter
min
EMI/EMC
typ
max
units
7.0
mA
UL/cUL 1950, TUV EN 60950
IS
C
safety approvals
conditions/description
EN 55022, EN 61000-4-(2,3,4,5,6,8,11), EN 61000-3-(2,3), ENV50204
leakage current
at 240 Vac
RoHS compliant
yes
ENVIRONMENTAL
parameter
conditions/description
min
max
units
0
50
°C
storage temperature
-20
85
°C
operating humidity
20
90
%
D
operating temperature
storage humidity
vibration
for 60 minutes, each axis
cui.com
typ
10
95
%
10
200
Hz
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 3 of 6
Load (%)
≈
100
ED
DERATING CURVES
80
60
50
40
≈
U
20
-25
0
10
20
30
40
50
60
70
TI
N
Ambient Temperature (°C)
MECHANICAL
parameter
conditions/description
weight
O
N
11.42 x 4.72 x 5.22 (290 x 120 x 132.5 mm)
D
IS
C
dimensions
min
cui.com
typ
4.5
max
units
Kg
inch
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 4 of 6
MECHANICAL DRAWING
D
IS
C
O
N
TI
N
U
ED
units: mm[inch]
tolerance: ±1.0mm unless otherwise specified
LOGIC CONNECTOR
1
VS+
output voltage remote sense+
2
VS-
output voltage remote sense-
3
VCI
command input voltage for output programming
4
VCO
5~10 Vdc reference for output programming
5
FAL
power failure detected
6
PG
power good signal
7
PAR
current sharing / parallel function
8
GND
return / output ground
9
INH
inhibit / remote on-off
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 5 of 6
D
IS
C
O
N
TI
N
U
ED
LOGIC CONNECTIONS
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-1K2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 6 of 6
REVISION HISTORY
description
date
06/28/2006
1.0
initial release
1.01
new template applied
1.02
V-Infinity branding removed
ED
rev.
08/20/2011
08/28/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.