Datasheet

For more information, please visit the product page.
date
08/28/2012
page
1 of 6
SERIES: VSUP-1K5 │ DESCRIPTION: AC-DC POWER SUPPLY
RoHS
output
power
ripple
and noise2
efficiency
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
125
1,500
120
84
100
1,500
150
85
83.3
1,500
150
85
62.5
1,500
150
88
30
50
1,500
150
88
36
41.6
1,500
150
88
48
31.2
1,500
150
89
25
1,500
150
90
(Vdc)
12
VSUP-1K5-15
15
VSUP-1K5-18
18
VSUP-1K5-24
24
N
VSUP-1K5-12
VSUP-1K5-30
VSUP-1K5-36
60
1. output voltage is measured at output power connector
2. ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel
IS
C
Notes:
O
VSUP-1K5-48
VSUP-1K5-60
output
current
TI
output
voltage1
MODEL
U
up to 1,500 W continuous power
universal input (90~264 Vac)
single output from 12~60 V
programmable output voltage
active power correction (98%)
current sharing capable
power good, remote sense, remote on/off control
built-in DC fan
over load, over voltage, over temperature, and short circuit protections
UL and TUV safety approvals
efficiency up to 90%
N
•
•
•
•
•
•
•
•
•
•
•
ED
FEATURES
PART NUMBER KEY
VSUP-1K5 - XX
Base Number
D
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUP-1K5 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 2 of 6
INPUT
parameter
conditions/description
min
voltage
typ
90
47
current
at 230 Vac
inrush current
peak measured at 230 Vac, cold start
power factor correction
at 230 Vac, full load
conditions/description
temperature coefficient
0 ~ 50°C
Vac
63
Hz
9
A
120
A
0.98
OUTPUT
parameter
units
264
ED
frequency
max
min
typ
max
U
±0.04
units
%/°C
hold-up time
230 Vac at full load
adjustability
adjustable with built-in trim pot
programming
output voltage programmable through external
1 ~ 5 V control voltage on VCI.
remote sense
Designated as (VS+) and (VS-). Total voltage compensation from cable losses with respect to the main
output.
remote inhibit
Designated as (INH), requires a low signal to inhibit the output.
current sharing
Designated as (PAR), use in parallel for forced current sharing function.
conditions/description
over voltage protection
typ
conditions/description
min
typ
%
100
%
max
units
135
%
max
units
7.0
mA
UL/cUL 1950, TUV EN60950
O
parameter
N
shutdown
SAFETY & COMPLIANCE
EN 55022, EN 61000-4-(2,3,4,5,6,8,11), EN 61000-3-(2,3), ENV50204
at 240 Vac
yes
IS
C
RoHS compliant
min
110
over current protection
leakage current
ms
N
parameter
EMI/EMC
20
TI
PROTECTION
safety approvals
12
±1.5
ENVIRONMENTAL
parameter
conditions/description
min
max
units
0
50
°C
storage temperature
-20
85
°C
operating humidity
20
90
%
operating temperature
storage humidity
for 60 minutes, each axis
D
vibration
cui.com
typ
10
95
%
10
200
Hz
For more information, please visit the product page.
CUI Inc │ SERIES: VSUP-1K5 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 3 of 6
≈
80
60
50
40
≈
U
20
10
20
30
40
50
60
70
TI
N
Ambient Temperature (°C)
N
0
O
-25
D
IS
C
Load (%)
100
ED
DERATING CURVES
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUP-1K5 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 4 of 6
MECHANICAL
parameter
conditions/description
min
typ
weight
10.98 x 7.99 x 2.5 (279 x 203 x 63.5 mm)
O
N
TI
N
U
units: mm[inch]
tolerance: ±1.0mm unless otherwise specified
IS
C
units
Kg
inch
MECHANICAL DRAWING
D
max
ED
dimensions
3.8
LOGIC CONNECTOR (CN1)
1
VCI
command input voltage for output programming
2
REF
5 Vdc reference output, can be used to derive VCI
3
PG
power good signal
4
GND
return / output ground
5
INH
inhibit / remote on-off
6
PAR
current sharing / parallel function
1
VS+
output voltage remote sense+
2
VS-
output voltage remote sense-
REMOTE SENSE (CN2)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUP-1K5 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 5 of 6
TI
N
U
ED
LOGIC CONNECTIONS
D
IS
C
O
N
1K
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUP-1K5 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 6 of 6
REVISION HISTORY
description
date
02/07/2007
1.0
initial release
1.01
new template applied
1.02
V-Infinity branding removed
ED
rev.
07/02/2009
08/28/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.