SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
100 W power
universal input (90~264 Vac)
single regulated outputs
over voltage, over current, and short circuit protections
UL/cUL safety approvals
level V efficiency
power factor correction
custom designs available
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
8.34
100
240
V
6.25
100
320
V
5.27
100
380
V
4.17
100
480
V
2.78
100
480
V
2.09
100
480
V
12
ETSA160625U
16
ETSA190527U
19
ETSA240417U
24
ETSA360278U
36
N
ETSA120834U
ETSA480209U
48
efficiency
level
1. Ripple and noise measured with 20 MHz bandwidth oscilloscope, each output terminated with 10 µF/50 V electrolytic and 0.1 µF ceramic capacitors.
O
Notes:
TI
MODEL
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
PART NUMBER KEY
D
IS
C
ETSA120834UX - P51 - WP - CXX
Base Number
example of 12 Vdc, 8.34 A
Input Cable:
“Blank” = No Cable
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
DC Plug Type
cui.com
Factory
Designation
Reserved for Custom
Configurations
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/09/2014 │ page 2 of 7
INPUT
parameter
conditions/description
min
voltage
47
current
at 90 Vac, 50 Hz
inrush current
at 230 Vac, cold start
power factor correction
at full load
OUTPUT
conditions/description
min
-2
at 115/230 Vac, 50/60 Hz, full load
temperature coefficient
conditions/description
auto latch off
min
63
Hz
2.5
A
150
A
0.5
W
max
units
over current protection
auto restart when overload is removed
short circuit protection
auto shutdown, auto restart when short circuit removed
conditions/description
isolation voltage
input to output for 4 seconds
input to ground for 4 seconds
isolation resistance
input to output at 500 Vdc
input to ground at 500 Vdc
safety approvals
UL/cUL, GS
EMI/EMC
FCC Part 15 Class B, EN55022/EN55024 Class B, CE
MTBF
at full load, 25°C
O
typ
%
ms
±0.05
%/°C
max
units
130
%
110
160
%
max
units
min
N
parameter
+5
110
TI
parameter
over voltage protection
SAFETY & COMPLIANCE
Vac
16
N
PROTECTIONS
typ
U
total regulation
hold-up
units
264
0.9
no load power consumption
parameter
max
ED
frequency
RoHS
typ
90
typ
4,242
2,121
Vdc
Vdc
20
20
MΩ
MΩ
140,000
hrs
2011/65/EU
ENVIRONMENTAL
conditions/description
min
max
units
0
60
°C
12 Vdc & 16 Vdc output models
all other models
-10
-10
85
70
°C
°C
operating humidity
non-condensing
20
90
%
storage humidity
non-condensing
20
90
%
IS
C
parameter
derate linearly 2.5% per °C from 41~60°C
storage temperature
D
operating temperature
cui.com
typ
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/09/2014 │ page 3 of 7
MECHANICAL
parameter
conditions/description
dimensions
170 x 85 x 44
input plug
IEC320 / C14
min
typ
max
units
ED
mm
MECHANICAL DRAWING
D
IS
C
O
N
TI
N
U
units: mm
tolerance: ±0.5 mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/09/2014 │ page 4 of 7
DC CORD
ED
units: mm
See Table 1
SECTIONAL DRAWING
N
TI
N
U
4P POWER DIN
FRONT VIEW
Table 1
MODEL NO.
CABLE
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA160625U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA190527U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA240417U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA360278U
16 AWG, Black, UL1185 80/90°C, 300 V,
16 AWGX1C + aluminum shield (16 AWG)
ETSA480209U
16 AWG, Black, UL1185 80/90°C, 300 V,
16 AWGX1C + aluminum shield (16 AWG)
D
IS
C
O
ETSA120834U
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/09/2014 │ page 5 of 7
AC CORD
NORTH AMERICAN INPUT CABLE
U
1830±50
ED
units: mm
EUROPEAN INPUT CABLE
TI
N
units: mm
N
1830±30
UNITED KINGDOM INPUT CABLE
IS
C
O
units: mm
1800±50
AUSTRALIAN INPUT CABLE
D
units: mm
1830±30
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/09/2014 │ page 6 of 7
AC CORD (CONTINUED)
CHINA INPUT CABLE
1830±50
SOUTH KOREA INPUT CABLE
N
U
units: mm
ED
units: mm
1800±30
TI
BRAZIL INPUT CABLE
N
units: mm
1830±30
IS
C
units: mm
O
SOUTH AFRICA INPUT CABLE
1830±30
JAPAN INPUT CABLE
D
units: mm
1830±30
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 100W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/09/2014 │ page 7 of 7
REVISION HISTORY
description
date
1.0
initial release
11/22/2013
1.01
added ac cord options
ED
rev.
10/09/2014
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.