データシート

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date
05/08/2015
page
1 of 6
SERIES: ETSA 150W U │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
150 W power
universal input (90~264 Vac)
single regulated outputs
over voltage, over current, and short circuit protections
UL/cUL safety approvals
level VI efficiency
power factor correction
custom designs available
MODEL
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
ETSA1201167U
12
11.67
140
240
VI
ETSA160938U
16
9.38
150
320
VI
ETSA190790U
19
7.90
150
380
VI
ETSA240625U
24
6.25
150
480
VI
ETSA360417U
36
4.17
150
480
VI
ETSA480313U
48
3.13
150
480
VI
Notes:
efficiency
level
1. Ripple and noise measured with 20 MHz bandwidth oscilloscope, each output terminated with 10 µF/50 V electrolytic and 0.1 µF ceramic capacitors.
PART NUMBER KEY
ETSA160938UX - P51 - WP - CXX
Base Number
example of 16 Vdc, 9.38 A
DC Plug Type:
Input Cable:
4 Pin Power DIN
“Blank” = No Cable
C = North America input cable
2 = Europe input cable
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
Factory
Designation
Reserved for Custom
Configurations
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 150W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/08/2015 │ page 2 of 6
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
current
at 90 Vac, 50 Hz
inrush current
at 230 Vac, cold start
power factor correction
at full load
max
units
264
Vac
63
Hz
2.5
A
150
A
0.15
W
max
units
0.9
no load power consumption
OUTPUT
parameter
conditions/description
regulation
12, 16, 19 Vdc output models
24, 36, 48 Vdc output models
hold-up time
at 115/230 Vac, full load
min
typ
±5
±3
%
%
16
ms
temperature coefficient
±0.05
%/°C
max
units
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
output latch off
110
130
%
over current protection
output shut down, auto recovery
110
160
%
short circuit protection
output shut down, auto recovery
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output for 4 seconds
input to frame ground for 4 seconds
isolation resistance
input to output at 500 Vdc
input to frame ground at 500 Vdc
safety approvals
UL/cUL, GS
EMI/EMC
FCC Part 15 Class B, EN55022/EN55024 Class B, CE
MTBF
at full load, 25°C
RoHS
2011/65/EU
typ
4,242
2,121
Vdc
Vdc
20
20
MΩ
MΩ
140,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
derate linearly 2.5% per °C from 41~60°C
storage temperature
typ
max
units
0
60
°C
-10
85
°C
operating humidity
non-condensing
20
90
%
storage humidity
non-condensing
20
90
%
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 150W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/08/2015 │ page 3 of 6
MECHANICAL
parameter
conditions/description
dimensions
170 x 85 x 44
inlet plug
IEC320 / C14
min
typ
max
units
mm
MECHANICAL DRAWING
units: mm
tolerance: ±0.5 mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 150W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/08/2015 │ page 4 of 6
DC CORD
units: mm
See Table 1
SECTIONAL DRAWING
4P POWER DIN
FRONT VIEW
Table 1
MODEL NO.
CABLE
ETSA1201167U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA160938U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA190790U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA240625U
14 AWG, Black, UL1571, 80°C, 30 V,
14 AWGX1C + aluminum shield (14 AWG)
ETSA360417U
16 AWG, Black, UL1185 80/90°C, 300 V,
16 AWGX1C + aluminum shield (16 AWG)
ETSA480313U
16 AWG, Black, UL1185 80/90°C, 300 V,
16 AWGX1C + aluminum shield (16 AWG)
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 150W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/08/2015 │ page 5 of 6
AC CORD
units: mm
cord length
NORTH AMERICA
EUROPE
UNITED KINGDOM
AUSTRALIA
CHINA
SOUTH KOREA
BRAZIL
SOUTH AFRICA
JAPAN
Table 2
AC INPUT
CORD LENGTH
North America
1,830 mm ±50
Europe
1,830 mm ±30
United Kingdom
1,800 mm ±50
Australia
1,830 mm ±30
China
1,830 mm ±50
South Korea
1,800 mm ±30
Brazil
1,830 mm ±30
South Africa
1,830 mm ±30
Japan
1,830 mm ±30
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 150W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/08/2015 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
11/22/2013
1.01
added ac cord options
10/09/2014
1.02
updated to level VI efficiency
05/08/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.