INTERSIL SP600

SP600
Semiconductor
July 1998
WN
ITHDRA TE
W
T
R
A
P
OLE
SS OBS NS
PROCE
S
DE IG
NO NEW
Features
File Number 2428.4
Half Bridge 500VDC Driver
• Maximum Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . 500V
The SP600 is a smart power high voltage integrated circuit
(HVIC) optimized to drive MOS gated power devices in halfbridge topologies. It provides the necessary control and
management for PWM motor drive, power supply, and UPS
applications.
• Ability to Interface and Drive Standard and Current
Sensing N-Channel Power MOSFET/IGBT Devices
• Creation and Management of a Floating Power Supply
for Upper Rail Drive
• Simultaneous Conduction Lockout
• Overcurrent Protection
Ordering Information
• Single Low Current Bias Supply Operation
PART
• Latch Immune CMOS Logic
PACKAGE
-40oC to +85oC
SP600
• Peak Drive in Excess of 0.5A
Pinout
TEMPERATURE
22 Lead Plastic DIP
Functional Block Diagram
VBS
SP600 (PDIP)
TOP VIEW
12
D1U
VBIAS 3
VDD 4
VSS 5
VBIAS 10Ω RND
21 BOT
3
VDD
20 NC
19 D1U
4
18 G1U
VDF
19
G1U
IONT
LEVEL
SHIFT
S
IOFFT
18
G2U
Q
R
17
3.5Ω RBS
TRIPU
UV
LOCK
OUT
11
UPPER
ITRIPSEL 2
22 TOP
+
-
TRIPL 6
17 G2U
CL1 7
16 CL2
G2L 8
15 TRIPU
16
G1L 9
14 PHASE
PHASE
D1L 10
13 VOUT
TOP
VDF 11
12 VBS
22
15
CL2
S
ITRIPSEL
Q
14
3.5Ω RO
R
13
VOUT
D1L
10
IONB
S
BOT
CMOS
TIMING
AND
CONTROL
21
FAULT
IOFFB
VOUT
SENSE
AND
FILTER
FAULT
750Ω RF
1
Q
R
Q
9
G2L
8
UV
LOCK
OUT
TRIPL
+
-
S
6
CL1
R
FILTER
G1L
LOWER
FAULT 1
7
ITRIPSEL
S
Q
R
ITRIPSEL
2
1
VSS
5
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
Copyright © Harris Corporation 1998
SP600
Absolute Maximum Ratings
Full Temperature Range, All
Voltage Referenced to VSS Unless Otherwise Noted. Note 1, Note 2.
Thermal Information
Low Voltage Power Supply, VBIAS (Note 1) . . . . . . . . . . . . . . 18VDC
Floating Low Voltage Boot Strap . . . . . . . . . . . . . . . . . . . . . . 18VDC
Power Supply to Phase, VBS
Low Voltage Signal Pins
Fault, ITRIPSEL , VDD, TRIPL , CL1, G2L . . . -0.5VDC to VDD +0.5
G1L, D1L, VDF, TOP, BOT
CL2, TRIPU , G1U, G2U, D1U to Phase. . . . -0.5VDC to VBS +0.5
High Voltage Pins
Phase, VPHASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500VDC
(VBS , VOUT , TRIPU , CL2, G2U and D1U: 0V-18V Higher Than
Phase)
Dynamic High Voltage Rating Phase, . . . . . . . . . . . . . 10,000V/µs
DVPHASE/DT
Thermal Resistance
θJA
Plastic DIP Package . . . . . . . . . . . . . . . . . . . . . . . .
75oC/W
Maximum Package Power Dissipation at TA = +85oC, PO
Plastic DIP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mW
Operating Ambient Temperature Range, TA . . . . . . .-25oC to +85oC
Storage Temperature Range, TS . . . . . . . . . . . . . . .-40oC to +150oC
Lead Temperature (Soldering 10s) . . . . . . . . . . . . . . . . . . . . +265oC
NOTES:
1. Care must be taken in the application of VBIAS as not to impose high peak dissipation demands on a relatively small metallized noise dropping resistor (RND).
Prolonged high peak currents may result if +15VDC is applied abruptly and/or if the local bypass capacitor CDD is large. It is suggested that CDD be ≤ 10MFD.
If it is desirable to switch the 15VDC source or if a CDD is larger, additional series impedance may be required.
2. Consult factory for additional package offerings.
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications
(VBIAS = 15V, Pulsed <300ms), Unless Otherwise Noted, All Parameters Referenced to
VSS Except TRIPU , CL2, G1U, D1U, and VBS Referenced to PHASE. DF: VDF to VBS ,
CF: VBS to PHASE
PARAMETER
SYMBOL
TEMP
MIN
TYP
MAX
UNITS
IIN
+25oC
-
20
30
µA
-40oC to +85oC
-
30
33
µA
+25oC
-
1.7
2.05
mA
-40oC to +85oC
-
1.7
2.1
mA
+25oC
-
1.7
2.05
mA
-40oC to +85oC
-
1.7
2.1
mA
+25oC
-
875
1000
µA
-40oC to +85oC
-
900
1060
µA
DC CHARACTERISTICS
Input Current (5V < VTOP , VBOT , VTRIPSEL < 15V)
IBIAS Quiescent Current (All Inputs Low)
IBIAS Quiescent Current
(VOUT ≥ VBIAS, and All Inputs Low)
IBS Quiescent Current Bootstrap Supply
TOP Threshold Level
IBIAS
IBIAS
L
H
IBS
VTOP
BOTTOM Threshold Level
VBOT
Current TRIPSELECT Threshold Level
Trip Lower and Upper Comparator Threshold
Level - Normal (ITRIPSEL = VSS)
Trip Lower and Upper Comparator Threshold
Level - Boost (ITRIPSEL = VDD) % of Measured
VTRIP L/U
VTRIPSEL
VTRIP L/U
N
VTRIP L/U
B
+25oC
7
8
9
V
-40oC to +85oC
6.95
8
9.1
V
+25oC
7
8
9
V
-40oC to +85oC
6.9
8
9.1
V
+25oC
7
8
9
V
-40oC to +85oC
6.95
8
9.1
V
+25oC
90
105
125
mV
-40oC to +85oC
90
105
127
mV
+25oC
110
130
150
%
-40oC to +85oC
109
130
152
%
N
Under Voltage Lockout Thresholds (VDD and VBS)
Phase Out of Status Voltage Threshold (PHASE)
2
VLOCK
VOSVT
+25oC
9
10
11.5
V
-40oC to +85oC
9.7
10.5
11.8
V
+25oC
5
7
9
V
-40oC to +85oC
4.7
7
9.6
V
SP600
Electrical Specifications
(VBIAS = 15V, Pulsed <300ms), Unless Otherwise Noted, All Parameters Referenced to
VSS Except TRIPU , CL2, G1U, D1U, and VBS Referenced to PHASE. DF: VDF to VBS ,
CF: VBS to PHASE (Continued)
PARAMETER
SYMBOL
TEMP
RF
+25oC
500
760
1000
Ω
-40oC to +85oC
450
760
1100
Ω
+25oC
12
17
23
Ω
-40oC to +85oC
7
17
29
Ω
Faultbar Impedance at IFBAR = 1mA
Upper/Lower Source Impedances (ISOURCE = 10mA)
Upper/Lower Sink Impedances (ISINK = 10mA)
RSO L/U
Noise Clamping Zeners; CL2 and CL1 (IZ = 50mA)
UNITS
8
12
16
Ω
5
12
20
Ω
+25oC
2
3.5
5
Ω
-40oC to +85oC
5.6
Ω
1.4
3.5
+25oC
6
10
14
Ω
-40oC to +85oC
5.4
10
14.6
Ω
ILK
+25oC
-
1
3
µA
VD1U/L
+25oC
0.40
0.90
1.40
V
VCL2/1-LOW
+25oC
6.35
6.61
6.85
V
-40oC to +85oC
6.15
6.61
7.15
V
+25oC
7.0
8.5
8.0
V
+25oC
2
3.5
5
Ω
-40oC to +85oC
1.4
3.5
5.6
Ω
RND
High Voltage Leakage (500V VBS, VOUT, PHASE,
TRIPU, CL2, G1U, G2U, and D1U to VSS. All other
Pins at VSS)
Noise Clamping Zeners; CL2 and CL1 (IZ = 10mA)
MAX
-40oC to +85oC
RBS
Noise Dropping Resistor Impedance
Miller Clamp Diodes; D1U and D1L (ID = 10mA)
TYP
+25oC
RSI L/U
Bootstrap Supply Current Limiting Impedance
MIN
VCL2/1HIGH
VOUT Limiting Resistance
RO
NOTE: Maximum Steady State ÷ 15VDC Supply Current = IBIAS
Switching Specifications
÷ IBS
(All Referenced to VSS , Except: TRIPU , Cl2, G1U, G2U, and D1U Referenced to PHASE.
DF : VDF to VBS , CF : VBS to PHASE)
PARAMETER
Refresh One Shot Timer
Delay Time of Trip I/U Voltage (ITRIPSEL low) to
G2U/G2L Low (50% Overdrive)
SYMBOL
TEMP
tREF
+25oC
200
350
500
µs
-40oC to +85oC
180
350
540
µs
+25oC
2
3
4
µs
-40oC to +85oC
1.85
3
4.35
µs
tOFF
TN
Delay Time of Trip I Voltage (ITRIPSEL low) to
Faultbar Low
tFN
Delay Time of Phase Out of Status to Faultbar
Low (TOP High)
tOSVF
Minimum Logic Input Pulse Width: TOP and
BOTTOM
Minimum G1U/G1L On Time
tMINIW
tON
Minimum Pulsed Off Time, G2U/G2L
Turn On Delay Time of G1U (BISTATE MODE)
3
L
tOFF
tON
D
MIN
TYP
MAX
UNITS
+25oC
2
3
4
µs
-40oC to +85oC
1.85
3
4.35
µs
+25oC
500
700
900
ns
-40oC to +85oC
400
700
1050
ns
+25oC
300
430
600
ns
-40oC to +85oC
275
430
660
ns
+25oC
1.6
2.3
3.1
µs
-40oC to +85oC
µs
1.5
2.4
3.4
+25oC
1.3
2.0
3.4
µs
-40oC to +85oC
1.05
2.1
3.9
µs
+25oC
2.5
3.2
4.5
µs
-40oC to +85oC
2.1
3.3
5.2
µs
SP600
Switching Specifications
(All Referenced to VSS , Except: TRIPU , Cl2, G1U, G2U, and D1U Referenced to PHASE.
DF : VDF to VBS , CF : VBS to PHASE) (Continued)
PARAMETER
SYMBOL
Turn On Delay Time of G1L (BISTATE MODE)
tON
D
Turn On Delay Time of G1U
(THREE-STATE MODE)
tON
Turn On Delay Time of G1L
(THREE-STATE MODE)
tON
D
D
Turn Off Delay Time of G2U and G2L
Minimum Dead Time: G1U off to G1L on, or G1L
off to G1U on (BISTATE MODE)
Fault Reset Delay to Clear Faultbar
Rise Time of Upper and Lower Driver
(Load = 2000pF)
Fall Time of Upper and Lower Driver
(Load = 2000pF)
tOFF
D
tD.T.
tR.T.
tR U/L
tF U/L
TEMP
MIN
TYP
MAX
UNITS
+25oC
2.5
3.2
4.5
µs
-40oC to +85oC
2.1
3.3
5.2
µs
+25oC
0.75
1.0
1.5
µs
-40oC to +85oC
0.60
1.1
1.75
µs
+25oC
0.75
1.0
1.5
µs
-40oC to +85oC
0.60
1.1
1.75
µs
+25oC
0.75
1.0
1.45
µs
-40oC to +85oC
0.60
1.1
1.75
µs
+25oC
1.5
2.5
3.5
µs
-40oC to +85oC
µs
1.2
2.6
4
+25oC
3.4
4.5
6.6
µs
-40oC to +85oC
3.15
4.8
7.4
µs
+25oC
25
50
100
ns
-40oC to +85oC
15
50
115
ns
+25oC
25
50
100
ns
-40oC to +85oC
15
50
115
ns
Recommended Operating Conditions and Functional Pin Description
PARAMETER
FAULTBAR
ITRIPSELECT
VBIAS
CONDITION
Open Drain Fault Indicator Output
Digital Input Command to Increase TRIPL and TRIPU Threshold by 30%
14.5V to 16.5V with 15V nominal, ≅ 1.5mA DC BIAS Current
VDD
CDD to VSS
VSS
COMMON
TRIP I
CL1
G2L and G1L
(All Voltages Referenced to VSS, Unless
Otherwise Noted. See Figure 1)
100mV Signal to Shut Off LOWER Drive and Trigger a Fault Output
Lower Noise Clamp Zener
Low Impedance Driver Designed to Drive Power MOS Transistors (LOWER)
VDF
Current Limiting Charging Resistor for Bootstrap Capacitor Power Supply
VBS
Bootstrap Supply, Normally a Diode Drop Below VDD Voltage with Respect to the Floating PHASE Reference
VOUT
Load Connection Node
PHASE
Floating Reference Point for High Side Control Circuitry: VBS, TRIPU, CL2, G1U, G2U and D1U
TRIPU
100mV Signal, Referenced to PHASE, to Shut Off UPPER Drive
CL2
G2U and G1U
Upper Noise Clamp Zener
Low Impedance Driver Designed to Drive Power MOS Transistors (UPPER)
TOP
Digital Input to Command the UPPER On
BOT
Digital Input to Command the LOWER On
D1U
Miller Clamp UPPER to VBS
D1L
Miller Clamp LOWER to VDD
4
SP600
Timing Diagram
TOP
TOP
1
0
BOT
REFRESH
ONE SHOT
IONB
0
1
0
BOT
IOFFT
IONT
IOFFB
REFRESH
ONE SHOT
0
1
IONB
0
IOFFT
0
1
IONT
0
1
IOFFB
0
VOUT
0
1
0
0
1
0
1
0
1
0
1
UPPER
0
0
1
LOWER
1
1
VALID BOTON
0
1
1
UPPER
1
0
1
1
VALID BOTON
1
LOWER
0
VDC
VOUT
COM
THREE-STATE MODE SLOWER THAN REFRESH ONE SHOT TIMER
1
0
VDC
COM
BISTATE MODE SLOWER THAN REFRESH ONE SHOT TIMER
NOTE: BOT switching not relevant.
Typical Circuit Configuration
TRUTH TABLE
Applicable to Typical Circuit Configuration (Figure 1)
INPUTS
OUTPUTS
TOP
BOT
TRIPL
TRIPU
PHASE
VBIAS
UPPER
LOWER
FAULT BAR
0
0
0
X
X
1
0
0
1
1
1
0
0
1
1
1
0
1
1
1
0
1
1
1
0
0
0
1
1
0
X
0
1
0
0
0
X
X
1
X
X
1
0
0
0
0
1
0
X
X
1
0
1
1
1
0
0
X
X
1
0
0
1
X
X
X
X
X
0
0
0
0
NOTE: 0 = False, 1 = True, X = Don’t Care
5
SP600
25VDC ≤ VLINK ≤ 500VDC
RCU RDU
RPU
19
18
17
D1U G1U G2U TRIPU
SYSTEM CONTROL
21
22
1
2
14
15
PHASE
VOUT
VBS
BOT
VDF
TOP
SP600
HVIC
D1L
FAULT
G1L
ITRIPSELECT
G2L
VBIAS VDD
3
15V
IBIAS
VSS
4
TRIPL
13
12
CF
11 DF
VOUT
IBS
10
LOAD
9
RCL
8
RDL
6
RPL
5
COM
CDD
FIGURE 1. TYPICAL CIRCUIT CONFIGURATION
LEGEND
Application Specific
RCU
Upper Gate Charging Resistor
Application Specific
RDU
Upper Gate Discharge Resistor
Application Specific
RPU
Upper Current Pilot Resistor
Application Specific
RCL
Lower Gate Charging Resistor
Application Specific
RDL
Lower Gate Discharging Resistor
Application Specific
RPL
Lower Current Pilot Resistor
3µF at ≥ 15DC
CDD
Local LV Filter Capacitor
0.22µF Ceramic X7R at ≥ 15VDC
CF
Flying Capacitor for Bootstrap Supply
Harris P/N A114M or Equiv PRV ≥ VLINK
DF
Flying Diode for Bootstrap Supply
NOTE:
Refer to ‘Additional Product Offerings’ for information concerning power output devices.
6
SP600
Functional Description
The SP600 provides a flexible, digitally controlled power
function which is intended to be used as PWM drivers of
N-Channel MOSFETs and/or IGBTs for up to 240VAC line
rectified totem-pole applications. The CMOS driveable
inputs are filtered and captured by the control logic to determine the output state. The logic includes fixed timing to prohibit simultaneous conduction of the external power switches
and, thru the VOUT sense detector, verifies the output voltage state is in agreement with the controlled inputs. The
>11VDC floating power supply required to drive the upper rail
external power device is created and managed by the HVIC
through CF and DF. This capacitor is refreshed from the VDD
supply each time VOUT goes low. If the upper channel is
commanded on for a long period of time, the bootstrap
capacitor CF is automatically refreshed by bringing VOUT
low. This is accomplished by turning off the upper rail MOSFET/IGBT, momentarily turning on the lower rail output
device, followed by returning control back to the upper
switch. Otherwise, CF would gradually deplete its charge
allowing the upper switch to come out of saturation. The
upper and lower gate drivers allow for controlled charge and
discharge rates as well as facilitate the use of nearly lossless
current sensing power MOS devices. The over current trip
level can be boosted 30% on a pulse by pulse basis by logic
level ‘1’ applied to ITRIPSELECT. A FAULT output signal is
generated when any of the following occurs:
V bias is low
Over current is detected
V phase doesn’t agree with the input signal
Reset of FAULT is provided by externally removing power or
by holding both TOP and BOT inputs low for the required
reset time (trtMAX).
Each application can be individually optimized by the selection of external components tailored to ensure proper overall
system operation including:
Determining the ratings and sizing of MOSFETs and IGBTs,
mixed or matched, as well as flyback diodes (FBD).
The selection of separate gate charge (RC) and discharge
(RD) impedance chosen per the load capacitance, frequency
of operation, and DI/DT dependent recovery characteristics
of the associated FBDs. RD should also be sized to prevent
simultaneous bridge conduction by ensuring gate discharge
in the allotted turn off pulse width (tOFF MIN).
The selection of over current detection resistors (RP), compatible with current sense MOSFETs/IGBTs or shunt(s) may
be used.
For the floating bootstrap supply DF and CF must be determined. DF must support the worse case system bus voltage
and handle the charging currents of CF. Proper selection
should take into consideration TRR and TFR per the desired
operating frequency. Proper selection of CF is a trade off
between the minimum tON time of the lower rail to charge up
the capacitor, the amount of charge transfer required by the
load, and cost. Due to automatic refresh the capacitor is
replenished every 350µs TYP (or even sooner if input commands the TOP to switch at a faster repetition rate).
The local filter capacitor (CDD) should be sized sufficiently
large enough to transfer the charge to CF without causing a
significant droop in VDD. As a rule of thumb it should be at
least 10 times larger than CF and be located adjacent to the
VDD and VSS pins to minimize series resistance and
inductance.
Refer to Application Note AN8829 for more details about module operation and selection of external components.
7