INFINEON KPY41-MR

Silicon Pressure Sensor Module
KPY 41-MR
KPY 46-MA/MR
Features
•
•
•
•
•
•
•
•
Silicon piezoresistive technology
High stability
Excellent linearity
Temperature compensated span and offset voltages
Rugged stainless-steel housing
Threaded pressure connection port
Full scale 5 V output signal
Open collector output
Stainless Steel Package
Type and
Marking
Rated Pressure Over Pressure
Range
P0 … PN
PMAX
Unit
Ordering Code
KPY 41-MR
0 … 0.250
2
bar
Q62705-K …1)
KPY 42-MA
0 … 0.6
6
Q62705-K323
KPY 42-MR
0 … 0.6
6
Q62705-K324
KPY 43-MA
0 … 1.6
10
Q62705-K325
KPY 43-MR
0 … 1.6
10
Q62705-K326
KPY 44-MA
0…4
16
Q62705-K …1)
KPY 44-MR
0…4
16
Q62705-K …1)
KPY 45-MA
0 … 10
30
Q62705-K327
KPY 45-MR
0 … 10
30
Q62705-K328
KPY 46-MA
0 … 25
40
Q62705-K …1)
KPY 46-MR
0 … 25
40
Q62705-K …1)
1) delivery on request
Wire Configuration
+ VIN
brown
Gnd
blue
VOUT
black
For absolute pressure sensors, P0 = vacuum
For relative pressure sensors, P0 = atmospheric pressure
PN = rated pressure
Semiconductor Group
1
02.97
KPY 41-MR
KPY 46-MA/MR
Absolute Maximum Ratings
Parameter
Symbol
Limit Values
Unit
Operating temperature range
TA
Tstg
VIN
− 20 … + 85
˚C
− 40 … + 100
˚C
12 … 20
V
Storage temperature range
Supply voltage
Electrical Characteristics
at TA = 25 ˚C and VIN = 12 V
Parameter
Symbol
Limit Values
min.
Sensitivity 0 ... PN
−
−
−
−
−
−
20.0
8.3
3.1
1.25
0.5
0.2
−
−
−
−
−
−
VOUT
KPY 41 … 46-MA/R
V
5.95
6
6.05
V0
Offset voltage
P0
max.
V/bar
KPY 41-MR
KPY 42-MA/R
KPY 43-MA/R
KPY 44-MA/R
KPY 45-MA/R
KPY 46-MA/R
Output voltage
P = PN
typ.
KPY 41 … 46-MA/R
V
0.95
1.0
1.05
% VFS
Linearity error (Best fit straight line)
KPY 41 … 46-MA/R
−
−
± 0.25
% VFS
Repeatability and pressure hysteresis
KPY 41 … 46-MA/R
−
± 0.1
−
TCVOUT
Temperature error of span and offset
voltage (− 20°C … + 85 °C)
KPY 41 … 46-MA/R
% VFS
−
± 0.1
−
TH
Temperature hysteresis
KPY 41 … 46-MA/R
% VFS
−
± 0.1
−
Response time
ms
KPY 41 … 46-MA/R
−
< 0.1
−
Supply current
mA
KPY 41 … 46-MA/R
Semiconductor Group
Unit
−
2
−
24.0
KPY 41-MR
KPY 46-MA/MR
Package Outline
Stainless Steel Package
Weight approx. 70 g
Dimension in mm
Note: The pressure medium has contact to the following materials : Din 1.4305 Stainless
Steel, Viton® Nitrile rubber, Solvay®, Gold-plated Kovar®, Gold/Tin Solder, Silicon.
The user must ensure compatibility to these materials.
The rear-side of the silicon diaphragm carries the positive supply voltage. As the
pressure medium acts directly onto the silicon diaphragm, media which are ionic
or otherwise conductive cannot be applied to the sensor as this will lead to its
malfunction and/or destruction.
Exterior Packaging
I.e. tubes, trays, boxes are shown in our Data Book “Package Information”.
Semiconductor Group
3