Datasheet

For more information, please visit the product page.
date
09/11/2012
page
1 of 5
SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER
2 W isolated output
wide input (4:1)
industry standard 9 pin SIP package
dual unregulated outputs
1,500 V isolation
short circuit protection
wide temperature (-40~85°C)
efficiency up to 82%
U
•
•
•
•
•
•
•
•
ED
FEATURES
input
voltage
MODEL
output
current
output
power
ripple1
noise1
efficiency
max
(mA)
max
(W)
max
(mVp-p)
max
(mVp-p)
typ
(%)
2
300
150
76
typ
(Vdc)
range
(Vdc)
(Vdc)
24
9.0~36.0
±5
±200
TI
VWQAS2-Q24-D5-SIP
output
voltage
N
RoHS
VWQAS2-Q24-D9-SIP
24
9.0~36.0
±9
±111
2
300
150
78
VWQAS2-Q24-D12-SIP
24
9.0~36.0
±12
±83
2
300
150
82
24
9.0~36.0
±15
±67
2
300
150
81
VWQAS2-Q48-D5-SIP
48
18.0~72.0
±5
±200
2
300
150
75
VWQAS2-Q48-D9-SIP
48
VWQAS2-Q48-D12-SIP
48
VWQAS2-Q48-D15-SIP
48
18.0~72.0
±9
±111
2
300
150
77
18.0~72.0
±12
±83
2
300
150
81
18.0~72.0
±15
±67
2
300
150
80
O
1. ripple and noise are measured at 20 MHz BW
IS
C
Notes:
N
VWQAS2-Q24-D15-SIP
D
PART NUMBER KEY
Base Number
VWQAS2 - QXX - DXX -SIP
Input Voltage
Output Voltage
cui.com
Packaging Style
For more information, please visit the product page.
CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 2 of 5
INPUT
conditions/description
operating input voltage
min
typ
max
units
9.0
18.0
24
48
36.0
72.0
Vdc
Vdc
OUTPUT
parameter
conditions/description
line regulation
input voltage from low to high
min
load regulation
measured from 10% load to full load
voltage accuracy
refer to recommended circuit
switching frequency
100% load, input voltage range
ED
parameter
typ
max
units
±0.2
±0.75
%
±0.5
±1.5
%
±1
120
%
kHz
±0.03
U
temperature coefficient
±2
400
PROTECTIONS
conditions/description
short circuit protection
continuous, automatic recovery
min
SAFETY AND COMPLIANCE
N
parameter
typ
max
units
typ
max
units
conditions/description
isolation voltage
for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
1,000,000
hours
yes
ENVIRONMENTAL
operating temperature
storage temperature
storage humidity
temperature rise
min
max
units
-40
typ
85
°C
-55
125
°C
95
%
non-condensing
at full load
15
1.5 mm from case for 10 seconds
D
IS
C
lead temperature
conditions/description
O
parameter
N
RoHS compliant
TI
parameter
MTBF
min
%/°C
cui.com
°C
300
°C
For more information, please visit the product page.
CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 3 of 5
DERATING CURVES
ED
1. output power vs. ambient temperature
Load (%)
100
80
60
40
-40
-20
0
20
40
60 71
85
Ambient Temperature (°C)
100
parameter
conditions/description
dimensions
1.024 x 0.374 x 0.492 (26.00 x 9.50 x 12.50 mm)
case material
plastic (UL94-V0)
MECHANICAL DRAWING
date
7. 62
[ 0. 300]
2. 54
[ 0. 100]
12. 50
[ 0. 492]
3. 68
[ 0. 145]
cui.com
units
inch
7
g
PIN CONNECTIONS
4. 00
[ 0. 157]
2. 00
[ 0. 079]
max
9. 50
[ 0. 374]
2. 90
[ 0. 114]
0. 50
[ 0. 020]
0. 50
[ 0. 020]
D
IS
C
6 7 8 9
0. 30
[ 0. 012]
O
Bottom View
1 2 3
typ
N
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
26. 00
[ 1. 024]
min
TI
weight
120
N
MECHANICAL
U
20
PIN
FUNCTION
1
GND
2
Vin
3
CTRL
6
+Vo
7
0V
8
NC
9
-Vo
For more information, please visit the product page.
CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 4 of 5
APPLICATION NOTES
Vout
±5 V
±330
±9 V
±220
±12 V
±150
±15 V
±120
U
Table 1
Cout/μF (max)
ED
-All of the VWQAS2-SIP Series have been tested according to the following recommended testing circuit before leaving the factory.
This series should be tested under load (Figure 1). If you want to further decrease the input/output ripple, you can increase
capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high (Table 1).
NCs Terminals
Unless otherwise specified, NC terminals of all series are used for converter's interior circuit connection, and are not allowed connection of any external circuit
2.
CTRL Terminal
When open or high impedance, the converter will work well; When this pin is ‘high’; the converter will shutdown; It should be noted
that the input current should remain between 5-10mA,exceeding the maximum 20mA will cause permanent damage to the converter.
N
1.
TI
Ip
N
Figure 1
Input Current(A)
Input current
Nominal input voltage range. The input current of the power supply must be sufficient to the startup current (Ip) of the DC/DC module (Figure 2)
Input Voltage
Range
Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded.
IS
C
3.
O
Input Voltage (V)
D
No parallel connection or plug and play.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 5 of 5
REVISION HISTORY
description
date
1.0
initial release
07/23/2007
1.02
new template applied, V-Infinity branding removed
ED
rev.
09/11/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.