For more information, please visit the product page. date 09/11/2012 page 1 of 5 SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER 2 W isolated output wide input (4:1) industry standard 9 pin SIP package dual unregulated outputs 1,500 V isolation short circuit protection wide temperature (-40~85°C) efficiency up to 82% U • • • • • • • • ED FEATURES input voltage MODEL output current output power ripple1 noise1 efficiency max (mA) max (W) max (mVp-p) max (mVp-p) typ (%) 2 300 150 76 typ (Vdc) range (Vdc) (Vdc) 24 9.0~36.0 ±5 ±200 TI VWQAS2-Q24-D5-SIP output voltage N RoHS VWQAS2-Q24-D9-SIP 24 9.0~36.0 ±9 ±111 2 300 150 78 VWQAS2-Q24-D12-SIP 24 9.0~36.0 ±12 ±83 2 300 150 82 24 9.0~36.0 ±15 ±67 2 300 150 81 VWQAS2-Q48-D5-SIP 48 18.0~72.0 ±5 ±200 2 300 150 75 VWQAS2-Q48-D9-SIP 48 VWQAS2-Q48-D12-SIP 48 VWQAS2-Q48-D15-SIP 48 18.0~72.0 ±9 ±111 2 300 150 77 18.0~72.0 ±12 ±83 2 300 150 81 18.0~72.0 ±15 ±67 2 300 150 80 O 1. ripple and noise are measured at 20 MHz BW IS C Notes: N VWQAS2-Q24-D15-SIP D PART NUMBER KEY Base Number VWQAS2 - QXX - DXX -SIP Input Voltage Output Voltage cui.com Packaging Style For more information, please visit the product page. CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/11/2012 │ page 2 of 5 INPUT conditions/description operating input voltage min typ max units 9.0 18.0 24 48 36.0 72.0 Vdc Vdc OUTPUT parameter conditions/description line regulation input voltage from low to high min load regulation measured from 10% load to full load voltage accuracy refer to recommended circuit switching frequency 100% load, input voltage range ED parameter typ max units ±0.2 ±0.75 % ±0.5 ±1.5 % ±1 120 % kHz ±0.03 U temperature coefficient ±2 400 PROTECTIONS conditions/description short circuit protection continuous, automatic recovery min SAFETY AND COMPLIANCE N parameter typ max units typ max units conditions/description isolation voltage for 1 minute at 1 mA max. 1,500 Vdc isolation resistance at 500 Vdc 1,000 MΩ 1,000,000 hours yes ENVIRONMENTAL operating temperature storage temperature storage humidity temperature rise min max units -40 typ 85 °C -55 125 °C 95 % non-condensing at full load 15 1.5 mm from case for 10 seconds D IS C lead temperature conditions/description O parameter N RoHS compliant TI parameter MTBF min %/°C cui.com °C 300 °C For more information, please visit the product page. CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/11/2012 │ page 3 of 5 DERATING CURVES ED 1. output power vs. ambient temperature Load (%) 100 80 60 40 -40 -20 0 20 40 60 71 85 Ambient Temperature (°C) 100 parameter conditions/description dimensions 1.024 x 0.374 x 0.492 (26.00 x 9.50 x 12.50 mm) case material plastic (UL94-V0) MECHANICAL DRAWING date 7. 62 [ 0. 300] 2. 54 [ 0. 100] 12. 50 [ 0. 492] 3. 68 [ 0. 145] cui.com units inch 7 g PIN CONNECTIONS 4. 00 [ 0. 157] 2. 00 [ 0. 079] max 9. 50 [ 0. 374] 2. 90 [ 0. 114] 0. 50 [ 0. 020] 0. 50 [ 0. 020] D IS C 6 7 8 9 0. 30 [ 0. 012] O Bottom View 1 2 3 typ N units: mm [inches] tolerance: ±0.25 [±0.010] pin section tolerance: ±0.10 mm [±0.004] 26. 00 [ 1. 024] min TI weight 120 N MECHANICAL U 20 PIN FUNCTION 1 GND 2 Vin 3 CTRL 6 +Vo 7 0V 8 NC 9 -Vo For more information, please visit the product page. CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/11/2012 │ page 4 of 5 APPLICATION NOTES Vout ±5 V ±330 ±9 V ±220 ±12 V ±150 ±15 V ±120 U Table 1 Cout/μF (max) ED -All of the VWQAS2-SIP Series have been tested according to the following recommended testing circuit before leaving the factory. This series should be tested under load (Figure 1). If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high (Table 1). NCs Terminals Unless otherwise specified, NC terminals of all series are used for converter's interior circuit connection, and are not allowed connection of any external circuit 2. CTRL Terminal When open or high impedance, the converter will work well; When this pin is ‘high’; the converter will shutdown; It should be noted that the input current should remain between 5-10mA,exceeding the maximum 20mA will cause permanent damage to the converter. N 1. TI Ip N Figure 1 Input Current(A) Input current Nominal input voltage range. The input current of the power supply must be sufficient to the startup current (Ip) of the DC/DC module (Figure 2) Input Voltage Range Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded. IS C 3. O Input Voltage (V) D No parallel connection or plug and play. cui.com For more information, please visit the product page. CUI Inc │ SERIES: VWQAS2-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/11/2012 │ page 5 of 5 REVISION HISTORY description date 1.0 initial release 07/23/2007 1.02 new template applied, V-Infinity branding removed ED rev. 09/11/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.