Family data sheet

Product family datasheet
OPTOTRONIC
Constant current LED power supplies with 2DIM/0…10 V
Areas of application
_ Street and urban lighting
_ Industry
_ Suitable for luminaires of protection classes I and II
__
Product benefits
_ 2DIM functionality in one device (AstroDIM, 0…10 V)
_ High surge protection: up to 6 kV (in protection class I or II)
_ Fast programming without mains voltage
_ High efficiency and reliability
_ Great flexibility due to wide operating temperature range of -40…55 °C
_ Protection through double isolation between mains input and LED output
_ High IP protection (IP64)
Product features
_ Available with different wattage: 50 W, 100 W, 110 W
_ Input voltage: 120…277 V
_ Available with output current range: up to 1,400 mA
_ Flexible current setting with one additional wire (LEDset2)
_ AstroDIM for autonomous dimming with five independent levels (astro mode)
_ Isolated 0…10 V interface for unidirectional telemanagement systems
_ Constant lumen function
_ Overtemperature protection with external NTC or LEDset2 interface
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 11
Product family datasheet
Technical data
Electrical data
Product description
Nominal
voltage
Input voltage
AC
Nominal
current
Mains
frequency
Power factor λ
OT 50/120…277/800 2DIMLT2 P 1)
120…277 V
108…305 V 2)
0.27 A 3)
50…60 Hz
0.95/0.90
4)
15 %
OT 50/120…277/1A2 2DIMLT2 P 1)
120…277 V
108…305 V 2)
0.26 A 3)
50…60 Hz
0.95/0.90
4)
15 %
1)
120…277 V
108…305 V
2)
15 %
OT 110/120…277/1A4 2DIMLT2 P 1)
120…277 V
108…305 V 2)
15 %
Product description
Device
power loss
Inrush
current
Max. ECG no.
on circuit
breaker 10 A
(B)
OT 50/120…277/800 2DIMLT2 P 1)
10 W 5)
30 A 6)
10
7)
1)
5)
6)
10
7)
OT 100/120…277/800 2DIMLT2 P
OT 50/120…277/1A2 2DIMLT2 P
OT 100/120…277/800 2DIMLT2 P 1)
OT 110/120…277/1A4 2DIMLT2 P
__
1)
9.6 W
14 W 5)
15.0 W
30 A
55 A 14)
5)
55 A
14)
13)
50…60 Hz
0.95/0.90
4)
0.54 A 16)
50…60 Hz
0.95/0.90
4)
0.49 A
7
7)
7
7)
Max. ECG no.
on circuit
breaker 16 A
(B)
Total
harmonic
distortion
Max. ECG no. on circuit
breaker 25 A (B)
17
7)
28
7)
17
7)
28
7)
10
7)
16
7)
10
7)
16
7)
Product description
Max. no. of
ECGs on
16A MCB
with EBNOS
Surge capability (L/NGround)
Surge
capability (LN)
Nominal
output
power
ECG
efficiency
OT 50/120…277/800 2DIMLT2 P 1)
-
6 kV 8)
6 kV 9)
50 W 10)
86 % 11)
OT 50/120…277/1A2 2DIMLT2 P 1)
-
6 kV 8)
6 kV 9)
50 W 12)
86 % 11)
8)
9)
OT 100/120…277/800 2DIMLT2 P
1)
6 kV
OT 110/120…277/1A4 2DIMLT2 P 1)
6 kV
6 kV 8)
15)
90 % 11)
110 W 17)
90 % 11)
100 W
6 kV 9)
Product description
Nominal output
voltage
U-OUT
(working
voltage)
Nominal
output current
Output
current
tolerance
Output ripple current
(100 Hz)
OT 50/120…277/800 2DIMLT2 P 1)
30…115 V
120 V
350…800 mA
±5 %
30 %
OT 50/120…277/1A2 2DIMLT2 P 1)
20…55 V
60 V
600…1250 mA
±5 %
30 %
OT 100/120…277/800 2DIMLT2 P
1)
50…186 V
200 V
350…800 mA
±5 %
25 %
OT 110/120…277/1A4 2DIMLT2 P 1)
35…85 V
120 V
600…1400 mA
±5 %
25 %
Product description
Minimum output current
Galvanic isolation
OT 50/120…277/800 2DIMLT2 P
1)
105 mA
SELV
OT 50/120…277/1A2 2DIMLT2 P
1)
180 mA
SELV
OT 100/120…277/800 2DIMLT2 P 1)
105 mA
double/reinforced
1)
180 mA
SELV
OT 110/120…277/1A4 2DIMLT2 P
1) No on/off switching of lamps possible via 0...10 V interface
2) Permitted voltage range
3) At 230 V/0.50 A for 120 V
AC
4) Minimum/Full load at 230 V/Half load at 230 V
5) Maximum
6) t
width
= 250 µs (measured at 50 % I
June 24, 2016, 06:08:21
OPTOTRONIC
)
peak
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 11
Product family datasheet
7) Type B
8) EQUI @ 12 Ohm acc. to EN 61547
9) @ 2 Ohm, acc. to EN61547
10) Partial load 11…50 W
11) At full load, default current and 230 V
12) Partial load 12…50 W
13) At 230 V/0.86 A for 120 V
AC
= 230 µs (measured at 50 % I
)
width
peak
15) Partial Load 45…100 W
14) t
17) Partial Load 45…110 W
16) At 230 V/1.06 A for 120 V
AC
Dimensions & weight
Product description
Length
Width
Height
Mounting
hole
spacing,
length
Mounting
hole
spacing,
width
Product
weight
OT 50/120…277/800 2DIMLT2 P 1)
168.0 mm
50.0 mm
30.0 mm
152.0 mm
-
490.00 g
OT 50/120…277/1A2 2DIMLT2 P 1)
168.0 mm
50.0 mm
30.0 mm
152.0 mm
-
490.00 g
1)
168.0 mm
68.0 mm
38.0 mm
152.0 mm
740.00 g
OT 110/120…277/1A4 2DIMLT2 P 1)
168.0 mm
68.0 mm
38.0 mm
152.0 mm
740.00 g
Product description
Cable/wire length,
output side
Cable/wire length,
control input
Cable/wire length,
input side
OT 50/120…277/800 2DIMLT2 P 1)
280 mm 2)
280 mm 2)
300 mm 2)
OT 50/120…277/1A2 2DIMLT2 P 1)
280 mm 2)
280 mm 2)
300 mm 2)
2)
2)
300 mm 2)
280 mm 2)
300 mm 2)
OT 100/120…277/800 2DIMLT2 P
__
OT 100/120…277/800 2DIMLT2 P
1)
OT 110/120…277/1A4 2DIMLT2 P 1)
280 mm
280 mm 2)
280 mm
1) No on/off switching of lamps possible via 0...10 V interface
2) ± 20 mm
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 11
Product family datasheet
Product line drawing
OT 50/120…277/800 2DIMLT2 P
OT 50/120…277/1A2 2DIMLT2 P
OT 100/120…277/800 2DIMLT2 P
OT 110/120…277/1A4 2DIMLT2 P
__
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 11
Product family datasheet
Temperatures & operating conditions
Product description
Ambient
temperature range
Maximum
temperature at tc
test point
Max.housing
temperature in case
of fault
Permitted rel. humidity
during operation
OT 50/120…277/800 2DIMLT2 P 1)
-40…+55 °C 2)
85 °C 3)
120 °C
5…85 % 4)
OT 50/120…277/1A2 2DIMLT2 P 1)
-40…+55 °C 2)
80 °C 3)
120 °C
5…85 % 4)
5)
3)
120 °C
5…85 % 4)
85 °C 3)
120 °C
5…85 % 4)
OT 100/120…277/800 2DIMLT2 P
1)
OT 110/120…277/1A4 2DIMLT2 P 1)
-40…+55 °C
-40…+55 °C 6)
85 °C
1) No on/off switching of lamps possible via 0...10 V interface
2) T (max) = 50 °C for input voltage 120/277 V
a
AC
3) Maximum at the Tc-point
4) Non condensing, absolute humidity: 36g/m³
5) T (max) = 45°C for input voltage 120 V /T (max) = 50°C for input voltage 277 V
a
AC a
AC
6) T (max) = 40°C for input voltage 120 V /T (max) = 55°C for input voltage 277 V
a
AC a
AC
Lifespan
Product description
ECG lifetime
1)
80000 h 2)
OT 50/120…277/1A2 2DIMLT2 P 1)
80000 h 3)
OT 50/120…277/800 2DIMLT2 P
1)
80000 h 2)
OT 110/120…277/1A4 2DIMLT2 P 1)
80000 h 2)
OT 100/120…277/800 2DIMLT2 P
__
1) No on/off switching of lamps possible via 0...10 V interface
2) At T
= 75°C at T point / 10% failure rate
c
= 70°C at T point / 10% failure rate
case
c
case
3) At T
Expected Lifetime
Product name
OT 50/120…277/800
2DIMLT2 P
ECG ambient temperature [ta]
55
45
40
Temperature at tc-point [°C]
85
75
70
1)
1)
100000 1)
Lifetime [h]
OT 50/120…277/1A2
2DIMLT2 P
OT
110/120…277/1A4
2DIMLT2 P
June 24, 2016, 06:08:21
OPTOTRONIC
80000
ECG ambient temperature [ta]
55
45
40
Temperature at tc-point [°C]
80
70
65
2)
2)
100000 2)
Lifetime [h]
OT
100/120…277/800
2DIMLT2 P
50000
50000
80000
ECG ambient temperature [ta]
55
45
40
Temperature at tc-point [°C]
85
75
70
3)
3)
100000 3)
Lifetime [h]
50000
80000
ECG ambient temperature [ta]
55
45
40
Temperature at tc-point [°C]
85
75
70
4)
4)
100000 4)
Lifetime [h]
50000
80000
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 11
Product family datasheet
1) Max. 10% failure rate at tc max and input voltage 230 V
AC
2) Max. 10% failure rate at tc max and input voltage 230 V
AC
3) Max. 10% failure rate at tc max and input voltage 230 V
AC
4) Max. 10% failure rate at tc max and input voltage 230 V
AC
Capabilities
Product description
Dimmable
Dimming interface
Dimming range
Suitable for fixtures
with prot. class
OT 50/120…277/800 2DIMLT2 P 1)
Yes
2DIM / 1…10 V / AstroDIM
30…100 %
I / II
1)
OT 50/120…277/1A2 2DIMLT2 P
Yes
2DIM / 1…10 V / AstroDIM
30…100 %
I / II
OT 100/120…277/800 2DIMLT2 P 1)
Yes
2DIM / 1…10 V / AstroDIM
30…100 %
I / II
1)
Yes
2DIM / 1…10 V / AstroDIM
30…100 %
I / II
OT 110/120…277/1A4 2DIMLT2 P
Product description
Constant lumen function
NTC input
OT 50/120…277/800 2DIMLT2 P 1)
Programmable
Yes
2)
Yes
Programmable
Yes
2)
Yes
Programmable
Yes
2)
Yes
Programmable
Yes
2)
Yes
Product description
Overload protection
Short-circuit protection
No-load
proof
Max. cable
length to
lamp/LED
module
Cable/wire
types, input
side
OT 50/120…277/800 2DIMLT2 P 1)
Automatic reversible
Yes
Yes
10 m
AWG 18, solid
OT 50/120…277/1A2 2DIMLT2 P 1)
Automatic reversible
Yes
Yes
10 m
AWG 18, solid
OT 100/120…277/800 2DIMLT2 P 1)
Automatic reversible
Yes
Yes
10 m
AWG 18, solid
1)
Automatic reversible
Yes
Yes
10 m
AWG 18, solid
OT 50/120…277/1A2 2DIMLT2 P
1)
OT 100/120…277/800 2DIMLT2 P 1)
OT 110/120…277/1A4 2DIMLT2 P
__
OT 110/120…277/1A4 2DIMLT2 P
1)
Product description
Cable/wire
types, output
side
Cable/wire types, control
input
OT 50/120…277/800 2DIMLT2 P 1)
AWG 18, solid
AWG 18, solid
3)
OT 50/120…277/1A2 2DIMLT2 P 1)
AWG 18, solid
AWG 18, solid
3)
OT 100/120…277/800 2DIMLT2 P 1)
AWG 18, solid
AWG 18, solid
3)
OT 110/120…277/1A4 2DIMLT2 P 1)
AWG 18, solid
AWG 18, solid
3)
3)
3)
3)
3)
Overheating protection
3)
3)
3)
3)
1) No on/off switching of lamps possible via 0...10 V interface
2) 0…-20 % of set resistor value
3) Acc. to 1452 style
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 6 of 11
Product family datasheet
Certificates & standards
Product description
Type of
protection
Standards
OT 50/120…277/800 2DIMLT2 P 1)
IP64
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN
55015:2006 + A1:2007 + A2:2009/Acc. to EN 61547/Acc. to FCC 47 part
15 class A/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/UL-8750
OT 50/120…277/1A2 2DIMLT2 P 1)
IP64
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN
55015:2006 + A1:2007 + A2:2009/Acc. to EN 61547/Acc. to FCC 47 part
15 class A/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/UL-8750
OT 100/120…277/800 2DIMLT2 P 1)
IP64
Acc. to EN 61347/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN
55015:2006 + A1:2007 + A2:2009/Acc. to EN 61547/Acc. to FCC 47 part
15 class A/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/UL-8750
OT 110/120…277/1A4 2DIMLT2 P 1)
IP64
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN
55015:2006 + A1:2007 + A2:2009/Acc. to EN 61547/Acc. to FCC 47 part
15 class A/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/UL-8750
Product description
Approval marks – approval
1)
CE / ENEC 15 / UR / CQC
OT 50/120…277/1A2 2DIMLT2 P 1)
CE / ENEC 15 / UR / CQC
OT 50/120…277/800 2DIMLT2 P
1)
CE / ENEC 15 / UR / CQC
OT 110/120…277/1A4 2DIMLT2 P 1)
CE / ENEC 15 / UR / CQC
OT 100/120…277/800 2DIMLT2 P
1) No on/off switching of lamps possible via 0...10 V interface
__
Logistical data
Product description
Temperature
range at
storage
OT 50/120…277/800 2DIMLT2 P 1)
-25…80 °C
1)
-25…80 °C
OT 50/120…277/1A2 2DIMLT2 P
OT 100/120…277/800 2DIMLT2 P 1)
-25…80 °C
1)
-25…80 °C
OT 110/120…277/1A4 2DIMLT2 P
1) No on/off switching of lamps possible via 0...10 V interface
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 7 of 11
Product family datasheet
Wiring Diagram
__
OT 50/120…277/800 2DIMLT2 P, OT 50/120…277/1A2
2DIMLT2 P, OT 100/120…277/800 2DIMLT2 P, OT
110/120…277/1A4 2DIMLT2 P
OT 50/120…277/800 2DIMLT2 P, OT 50/120…277/1A2
2DIMLT2 P, OT 100/120…277/800 2DIMLT2 P, OT
110/120…277/1A4 2DIMLT2 P
OT 50/120…277/800 2DIMLT2 P, OT 50/120…277/1A2
2DIMLT2 P, OT 100/120…277/800 2DIMLT2 P, OT
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 8 of 11
Product family datasheet
110/120…277/1A4 2DIMLT2 P
Equipment / Accessories
__
_ OT Programmer hardware for configuration of 2DIM ECGs necessary
_ Programmable via Tuner4TRONIC software
Application advice
For more detailed application information and graphics please see product datasheet.
Additional product information
_ 800 mA type: Default output current is 700 mA without any resistor connected to the LEDset port.
_ 1250 mA type: Default output current is 1000 mA without any resistor connected to the LEDset port.
_ 1400 mA type: Default output current is 1000 mA without any resistor connected to the LEDset port.
_ The LEDset2 interface is disabled by default and needs to be activated by the programming software. In this case the LEDset2
interface is activated the external thermal protection feature is disabled.
_ The driver withstands an input voltage of up to 350 Vac for a maximum of two hours.
_ The driver may shut down the load if the input voltage of the load is below the allowed minimum output voltage until the
short circuit is removed or the correct load is connected and a power off/on cycle is performed.
_ In case the input voltage of the load exceeds the output voltage range of the driver, it automatically reduces the output
current to keep the output voltage controlled to the maximum allowed output voltage.
_ The driver automatically reduces the output current in case the maximum allowed output power is exceeded, as long as the
input voltage of the load is within the declared output voltage range of the driver. In all other cases the driver may shut down
the load.
_ The driver may shut down in case no load is connected to the driver output until the correct load is connected and a power
off/on cycle is performed. Hot-plug of the load or external switching on the secondary side is not allowed.
_ The EQUI (housing) shall be connected to the heat sink of the LED module to improve the surge withstand capability of the
system and EMI in critical luminaires.
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 9 of 11
Product family datasheet
_ By default the LEDset / NTCset / Prog+ port is set as NTCset port in resistor based mode with following values: start derating:
6.3 kOhm, end derating 5.0 kOhm, derating level 50 %.
_ The default dimming mode is 0…10 V, AstroDIM-PD is disabled.- 0…10 V: 30 % minimum dimming level
_ The constant lumen feature is disabled by default.
_ If any output level is below the physical min level, the physical min level will be used.
_ Dimming down to 10 % of the maximum rated output current could be enabled through the programming software, but the
compliance with EN 61000-3-2 must be checked below 30 %.
_ The driver is intended for built-in use. The luminaire manufacturer is responsible to prevent direct exposure for example to
sunlight, water, snow, ice.
_ Time to reach the set output current upon start-up is less than 4 s.
_ Programming of the driver via Prog+ and Prog- is only allowed without powering it via L/N.
_ For further details please consult the 2DIMLT2 application guide.
Sales and Technical Support
Sales and Technical Support www.osram.com
Download Data
File
Brochures
Overvoltage protection for LED street lighting (EN)
__
Brochures
Technical application guide 2DIMLT2 P LED drivers (GB)
Certificates
CB certificate OT 50 2DIMLT2 E
Certificates
ENEC certificate OT 2DIMLT2 P
Certificates
CCC Certificate OT 50120-277xxx 2DIMLT2 P
Declarations of conformity
EC-Conformity OT 50120-277xxx 2DIMLT2 P
Declarations of conformity
UL Conformity OT 50120_277xxx 2DIMLT2 P
Declarations of conformity
CB ENEC Information
Operating instructions
Instruction sheet OT 50 800 2DIMLT2 P
On-Pack-Info
Instruction sheet OT 50 1A2 2DIMLT2 P
Certificates
CCC Certificate OT 100120-277800 2DIMLT2 P
Certificates
CB Zertifikat OT 100 800 2DIMLT2 P
Declarations of conformity
ENEC Certificate OT 100 2DIMLT2 P
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 10 of 11
Product family datasheet
On-Pack-Info
Instruction sheet OT 100 800 2DIMLT2 P
Certificates
CCC Certificate OT 110120-2771A4 2DIMLT2 P
Certificates
CB Zertifikat OT 110 1A4 2DIMLT2 P
Declarations of conformity
ENEC Certificate OT 110 2DIMLT2 P
On-Pack-Info
Instruction sheet OT 110 1A4 2DIMLT2 P
Logistical Data
__
Product code
Product description
Packaging unit (Pieces/Unit)
Dimensions (length x width x
height)
Volume
Gross weight
4052899173781
OT 50/120…277/800
2DIMLT2 P
Shipping carton box
20
368 mm x 338 mm x 85 mm
10.57 dm³
10492.00 g
4052899173804
OT 50/120…277/1A2
2DIMLT2 P
Shipping carton box
20
368 mm x 338 mm x 85 mm
10.57 dm³
10492.00 g
4052899253414
OT 100/120…277/800
2DIMLT2 P
Shipping carton box
20
358 mm x 188 mm x 220 mm
14.81 dm³
15346.00 g
4052899253438
OT 110/120…277/1A4
2DIMLT2 P
Shipping carton box
20
358 mm x 188 mm x 220 mm
14.81 dm³
15346.00 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
June 24, 2016, 06:08:21
OPTOTRONIC
© 2016, OSRAM GmbH. All rights reserved.
Page 11 of 11