Specification Sheet

MILITARY
LoPAC MI Family
AC/DC POWER SUPPLIES
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Near unity power factor
EN61000-3-2 harmonic current compliance
Low profile package
Output power to 1,500 W
Up to six user specifiable outputs
AC input: 25 – 264 Vac
DC input: 100 – 380 Vdc (PFC Mini MI)
or 100 – 300 (PFC Micro MI and
PFC MicroS MI)
Power density up to 11 W/in 3
Integral cooling fans
47 – 500 Hz operation
Safely agency approvals: UL, cTÜVus
MIL-STD-810G for vibration and shock
MIL-STD 704 and 1399 for
overvoltage and transients
-40°C operation available
Optional conformal coating
LOPAC SLOT CONFIGURATIONS
PRODUCT INFORMATION
The MI versions of the PFC MicroS, PFC Micro and PFC Mini
are new members of the LoPAC family specifically designed for
demanding environments such as military and heavy industry.
Available as a one, two or three slot package, respectively, each
LoPAC slot can be configured with standard Vicor DC-DC
converter modules enabling up to six user-specifiable isolated
outputs with a power density of up to 11 W/in3.
For maximum versatility and flexibility, the LoPAC can be
configured with VI-26x (full brick), VI-J6x (half brick) or Maxi,
Mini, Micro V375 Series full, half and quarter-brick modules.
These modules cover the entire range of outputs from 1 to 100
Vdc and 25 to 600 Watts. The optimum solution can be factory
configured based on your exact voltage and power
requirements.
The DC-DC converter modules are used to populate each LoPAC converter slot.
Each slot can be configured in different ways depending on module sizes and
power limitations. The following table summarizes the available slot
configurations for each of the three LoPAC packages.
MAXIMUM OUTPUT POWER
TOTAL
MODEL
TYPE
# SLOTS
PFC Mini MI
3
PFC Micro MI
PFC MicroS MI
@ 230 VAC
@ 115 VAC
MODULES PER SLOT
1,500 W
800 W
1 Full or 2 Half
2
800 W
500 W
1 Full or 2 Half or 3 Quarter
1
600 W
500 W
1 Full or 2 Half or 3 Quarter
* Consult Powerbox Sales for additional technical or design information to configure a
tailored system.
The LoPACs are designed to meet MIL-STD-810G for shock and
vibration, MIL-STD-704 and 1399 for transients and
overvoltage, and have optional -40°C operational temp rating
and conformal coating. The supplies are compliant with all
EN61000-6-1 for conducted and radiated immunity, as well as
EN61000-3-2 for harmonic currents emissions and EN610003-3 for voltage flicker.
PART NUMBERING
PM
X1
Product Prefix
PM = PFC Mini MI
PC = PFC Micro MI
PS = PFC MicroS MI
Number of
output
Voltages
–
X2
X3
X4
XXXX
Number of
VI-200 / VI-J00
module(s)
Number of
Maxi/ Mini /
Micro module(s)
Optional
Factory
Assigned
Factory
Assigned
-X5
-X6
Optional Factory
Assigned
MI = Rugged Chassis
MC = Conformed Coat
Optional Codes[a]
LL = Low Leakage
QF = Quiet Fan (only
available on PFC Mini MI)
[a] Refer to model type design guide for more on the optional codes.
456
Doc. No. PBC9 Rev.C 28-4-11