ARTESYN DPF1500-4617

DPF1500 SERIES
Single output
•
•
•
•
•
•
•
•
•
The DPF1500 is a 1500W universal input AC/DC front end power supply in a fully
enclosed hot pluggable case with built-in fan, handle, IEC input connector, on/off
switch and DIN output signal connector. Providing a single 57.8V output at full load
with a full set of status signals. The DPF1500 is designed for use as a front end in
medium power communication applications adopting distributed power architecture.
The DPF1500 provides 1500W of output power and is fully compliant with EN610003-2. Standard features include current sharing and full protection against overvoltage,
overload and short circuit. Remote or local system monitoring is possible via a full set
of status signals that include fan fail, DC good, power fail, remote inhibit and current
monitoring. The DPF1500, with full international safety approval and the CE mark,
meets conducted emissions EN55022 level A. The DPF1500 can be used in
conjunction with our complete range of 3 to 200W DC/DC converters to fully configure
a distributed power system.
[ 2 YEAR WARRANTY ]
SPECIFICATION
Efficiency >90%
1500W front end
EN61000-3-2 compliant
12.6 x 6.5 x 4.9 inch size
Hot pluggable
N+1 redundancy
Full set of status signals
EN55022, EN55011 conducted emissions level A
UL, TÜV and CSA safety approvals
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
OUTPUT SPECIFICATIONS
Voltage set point
-57.8V ±0.1%
Total regulation
Main output
FL to NL
±5.0%
Rise time
At turn-on
Transient response
Main output
50% to 100%
step at 1A/µs
12% max. dev.,
1ms recovery
to 1.0%
Ripple and noise
Main output
0Hz to 20MHz
1.0V pk-pk
Overvoltage protection
latching
60V to 71V
1.0s, max.
Output power limit
Short circuit protection
1550W
Non-latching
Auto-recovery, 5A rms
max short circuit current
Current sharing
2V droop from 20%
to 100% rated load
Capacitive load
24µF max.
INPUT SPECIFICATIONS
Input voltage range
EN55022/11, FCC part 15
EN55022/11, FCC part 15
EN61000-3-2
EN61000-4-4
EN61000-4-5
Level 3
GENERAL SPECIFICATIONS
Hold-up time
240VAC, 60Hz FL
Efficiency
Isolation voltage
10ms @ 1500W
90% typ.
Input/output
Input/chassis
Switching frequency
3000VAC
1500VAC
50kHz
Approvals and
standards
EN60950, UL1950,
CSA C22.2 No. 950
Weight
6.9kg (15Ibs)
MTBF
Thermal performance
47Hz to 63Hz
Input surge current
220VAC, cold start
Input surge
300VAC
Safety ground
leakage current
230VAC, 50Hz
Input current
176VAC, 1500W
13A rms max.
Input fuse
Non-replaceable
15A
Power factor
220VAC
500,000 hours
demonstrated
40A max.
20ms
0.4mA
0.96 min.
Operating ambient, FL
0°C to +50°C
Non-operating
-40°C to +85°C
50°C to 70°C ambient,
Derate to
convection cooled
50% load
Cooling
Built-in fan
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration
5Hz to 500Hz
International Safety Standard Approvals
TÜV VDE0805/EN60950/IEC950
UL1950 File No. E136005
PAGE 1
Level A
Level A
Compliant
Level 3
ENVIRONMENTAL SPECIFICATIONS
176 to 264VAC
Input frequency range
Radiated noise
Conducted noise
Harmonic current emm.
Electrical fast
transients/bursts
Surge susceptibility
CSA C22.2 No. 950 File No. LR41062C
5% to 85% RH
10,000 feet max.
40,000 feet max.
2.4G rms peak
DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES
|
1500W AC/DC
1500 Watt
AC/DC PFC front-end for distributed power architectures
OUTPUT
TOTAL
OUTPUT CURRENT
VOLTAGE
MODEL NUMBER
REGULATION
-57.8V
27A max.
±5.0%
Detailed signal description
Power fail detect H
Open-collector signal reference to SEC Ground. A current limited 10K - 1.4W
resistor is connected to the collector of the output transistor for this signal.
The PFD H signal will be asserted, i.e. the transistor will open, when the input
voltage goes below 170VAC.
DPF1500-4617
Current monitor
This is an analog output proportional to the output current and is referenced
to output -. The signal consists of a voltage source connected through a 10K
- 1.4W - 1% resistor to this pin and delivers a signal whose value is 0.1 x
Iout. The signal is within the specified accuracy of ±10% when the output
current is greater than 6.0A.
Power good L
Open-collector signal reference to SEC Ground. A current limiting 10K 1.4W resistor is connected to the collector of the output transistor for this
signal.
The power good signal goes high, i.e. the transistor will open, when the
output voltage is out of specification or if the input power factor correction
stage is not functioning.
STATUS AND CONTROL SIGNALS
Fan fail H
Asserted in event of a failure
Power good L
Inhibit H +, This is a differential signal that is connected to an internal opto-coupler.
When the differential voltage applied between these two signals exceeds
3.5V, the output voltage is disabled. When the signals are less than 0.9V, the
output shall be enabled. The current drain is less than 6mA with the
differential voltage less than 3.5V.
Asserted when the output voltage
is within specification
Inhibit H and Return
Inhibits the output when the
differential voltage applied is >3.5V
Current monitor
Value = (0.1 x Iout) V
tolerance: ±10%
Unit present L
This pin is tied to SEC GND and can be used to detect the presence of the
unit in a system.
12.60
(320.04)
4.90
(124.46)
6.5
(165.1)
ALL DIMENSIONS IN INCHES (mm)
PIN NUMBER
Pins B2, B25
Pins B5, B28
Pins B8, B31
Pin B10
Pin B12
OUTPUT PIN CONNECTIONS
FUNCTION
PIN NUMBER
Output Pin B13
Chassis Ground
Pin B14
Output +
Pin C14
Power Good H
Pin B20
PFD L
Pins C11, C13
Mating connector
FUNCTION
Unit Present L
Inhibit H +
Inhibit H Current Monitor
SEC Ground
DIN M style
6 power pins
42 signal pins
Input
IEC320
http://www.artesyn.com
PAGE 2
DS_DPF1500_19980401.PDF
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.