MicroPower Direct Go Direct - MicroPower Direct - For Product, Performance and Price 350W AC-DC ACTIVE PFC SWITCHING POWER SUPPLY MPA350x SERIES FEATURES: Low leakage current 500uA max. at 240Vac or 200uA max. at 120Vacw Providing Peak Power 600W within 500uS duty duration Power Factor Corrected to EN61000-3-2 class D Compact Size: 4.25W X 8L X 2H inches Approved to UL CUL TUV CE and CB Optional Top Cover & Built-in Fan Universal AC input CB PRODUCT SPECIFICATIONS: Input Voltage: 47~63 Hz, 90 - 264 VAC full range. Input Current: 5.5A at 90 VAC full load. Inrush Current: 70A peak maximum (Measuring at 230 VAC and full load cold start). PFC: Power factor correction meets EN61000-3-2 Class D. Fan Drive: 12 VDC/160 mA offering to drive an external fan. Transient Response: output voltage returns to within 1% in less than 2.5 mS for a 50% dynamic load peak. Does not exceed 5%. Overshoot: Turn on-off overshoot does not exceed 5% nominal voltage. Efficiency: 70% for 3.3V, 75% for 5V, 80% for 12V and 82% minimum for other outputs (Measuring at 230V and full load). Turn On Delay: 1 second maximum at 120 VAC. Hold Up Time: 20 mS minimum at 120 VAC and 80% of rated maximum load. Adjustability: Output user adjustable ±5% minimum. Input Circuit Protection: 250V/6.3A fuse inserted. AC Under Voltage Protection: Power shuts down if Vin goes under 79V ±2V. Automatic recovery once Vin goes back over 86V ±3V. Over Load Protection: 110-135% hiccup mode, autorecovery. Short Circuit Protection: Continuous with auto-recovery. Over Voltage Protection: Unit latches down if the output exceeds 130%. To reset, recycle the AC input. Over-Temperature Protection: Output voltage drops if the operating ambient temp exceeds 85°C. Auto-recovery. Power Supply On: Green LED designated as LED 1 on the PCB. Power Good: Power on signal designated as PG on PCB goes high 100-500 mS after the output reaches the regulation limit. It goes low at least 1 mS before loss of regulation. Operating Temperature: 0°C to +50°C Storage Temperature: -20°C to +85°C Operating Humidity: 5% to 90% RH, Non-condensing Storage Humidity: 5% to 95% RH, Non-condensing Vibration: Frequency 5 to 50 Hz, acceleration ±7.35 M/(SxS) on X,Y and Z Axis EMC Standards: CISPR 22 / EN55022 class B, EN610003-2,3, EN61000-4-2,3,4,5,6,8,11, EN55024 CE Marked. Safety Regulation: Approved to UL60950, CSA C22.2 No. 60950, TUV EN60950 and CB certificate available. Leakage Current: 500 uA max. @ 240 VAC input. 200 uA max. @ 120VAC input. HI-POT Test: 3 Sec 1500 VAC input line to chassis; 3000 VAC primary to secondary; 1500 VAC Primary to core. Grounding Test: Apply 25A from the ground pin to the furthest earth connection point. Max. resistance 0.1ohm. Warranty: 2 years MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30°C Cooling: 30 CFM required to achieve full ratings Burn in: Applying full load at 230 VAC input in 45°C ±5°C burn-in room for 1 hour. Enclosure: U-case: 8 X 4.25 X 2 inches. U-case with FAN: 8 X 4.25 X 2.5 inches. Weight: Maximum weight is 800g. MicroPower Direct www.micropowerdirect.com 292 Page Street, Ste D Stoughton, MA 02072 ■ TEL: (781) 344-8226 ■ FAX: (781) 344-8481 ■ E-Mail: [email protected] MicroPower Direct Go Direct - MicroPower Direct - For Product, Performance and Price OUTPUT VOLTAGE / CURRENT RATING CHART: Measured at output power connector. Model Output voltage Max. Output current Regulation Ripple & noise Present Range Convection 30CFM MPA350x-03 3.3V 3-4V 30A 60A ±1% ±1% MPA350x-05 5V 5-6V 30A 60A ±1% ±1% MPA350x-12 12V 12-15V 19.16A 29.16A ±1% ±1% MPA350x-15 15V 12-15V 19.16A 29.16A ±1% ±1% MPA350x-18 18V 16-21V 14.37A 21.87A ±1% ±1% MPA350x-24 24V 22-30V 10.45A 15.9A ±1% ±1% MPA350x-36 36V 31-41V 7.41A 11.29A ±1% ±1% MPA350x-48 48V 42-53V 5.47A 8.33A ±1% ±1% MPA350x-54 54V 54-60V 4.25A 6.48A ±1% ±1% * MPA350x-00z series are designated as: x = U (U-channel), C(U-channel with Cover) or F(Cover with Internal fan). Z = T(Terminal Strips) or M(Molex connectors). * Ripple & noise measured from 10 kHz to 20 Mhz at output terminals with parallel 0.1µF ceramic and 22µF electrolytic capacitors. * Providing peak power to 600W within 500 uS for all models, longer duty duration need contact manufacture in advance. * 1% minimum load is required to maintain the ripple and regulation. * Output is fully isolated. * Models provided with the optional cover (MPA350C), require 30 CFM forced air flow to achieve max rating. OUTLINE DRAWING: Overall Size: 8(L) x 4.25(W) x 2(H)inches; Weight: Maximum weight is 800g Type A: U-Chassis only PG Mating JST XHP-2 or equivalent VO+ VO+ VO- N VO- L FAN1 Mounting hole 8 Places MicroPower Direct www.micropowerdirect.com 292 Page Street, Ste D Stoughton, MA 02072 ■ TEL: (781) 344-8226 ■ FAX: (781) 344-8481 ■ E-Mail: [email protected] MicroPower Direct Go Direct - MicroPower Direct - For Product, Performance and Price Type B: U-Chassis + Top Cover with Built-in Fan PG Mating JST XHP-2 or equivalent VO+ VO+ VO- N VO- L FAN1 Mounting hole 8 Places Notes: AC Input Connector: Howder 6-32. 3 pin Terminal block 9.5MM Center (HI-201-3P) or Molex Part No. 09-91-0500 or equivalent (5 pin,3 used). Pin1: FG; Pin2: Neutral; Pin3: Line. Howder Molex Output Connector: Howder 6-32. 4 pin Terminal block 9.5MM Center (HI-201-4P) or Molex Part No. 09-91-1000 or equivalent (10 pins) VO- : Pins 1-2 VO- : Pins 1-5 Output Pin Assignment: (See table in right) FAN and PG Connector: Mating JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02) VO+ : Pins 3-4 VO+ : Pins 6-10 Mounting Inserts: 8 Places 8-32 flush nut, screws must not protrude into unit by more than 4mm sees outline drawing for location. MicroPower Direct www.micropowerdirect.com 292 Page Street, Ste D Stoughton, MA 02072 ■ TEL: (781) 344-8226 ■ FAX: (781) 344-8481 ■ E-Mail: [email protected]