Ultra High Q Chip Inductors – 1812
• Low inductance (150 – 390 nH) 1812 size chip inductors
• Exceptionally high Q
• High current ratings – up to 1150 mA
• 2% tolerance for all values
Inductance2
DCR max5
Irms6
Percent SRF typ4
Q typ3
Part number1
(nH)tolerance
(MHz) (mOhms)(mA)
HA4031-AL_ 150 @ 50 MHz
2
75 @ 50 MHz
860
100
1150
HA4032-AL_ 180 @ 50 MHz
2
80 @ 50 MHz
850
105
1150
HA4033-AL_ 220 @ 50 MHz
2
80 @ 50 MHz
700
110
940
HA4034-AL_ 270 @ 50 MHz
2
85 @ 50 MHz
730
120
940
HA4035-AL_ 330 @ 50 MHz
2
80 @ 50 MHz
600
135
850
HA4036-AL_ 390 @ 50 MHz
2
80 @ 50 MHz
600
150
850
1.When ordering, please specify packaging code:
HA4036-ALC
Packaging:C
=7″ machine-ready reel. EIA-481 embossed plastic
tape (600 parts per full reel).
B=Less than full reel. In tape, but not machine ready.
To have a leader and trailer added ($25 charge),
use code letter C instead.
D
=13″ machine-ready reel. EIA-481 embossed plastic
tape. Factory order only, not stocked (2200 parts per
full reel).
2. Inductance measured using a Coilcraft SMD-A fixture in an Agilent/HP
4286A impedance analyzer with Coilcraft-provided correlation pieces.
3. Q measured using an Agilent/HP 4291A with an Agilent/HP 16193 test
fixture.
4. SRF measured using an Agilent/HP 8753D network analyzer and a
Coilcraft SMD-D test fixture.
5. DCR measured on a Cambridge Technology micro-ohmmeter and a
Coilcraft CCF859 test fixture.
6. Current that causes a 15°C temperature rise from 25°C ambient.
7. Electrical specifications at 25°C.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
C
B
overall
D
F
A
E
terminal
H
Pick and
place
material
I
G
J
F
I
Recommended
Land Pattern
Terminal wraparound:
approx 0.015/0,38 both ends
ABCD
maxmaxmax ref
E
F
Core material Ceramic
Terminations RoHS compliant silver-palladium-platinum-glass frit.
Other terminations available at additional cost.
Weight 109 – 128 mg
Ambient temperature –40°C to +125°C with Irms current, +125°C to
+140°C with derated current
Storage temperature Component: –40°C to +140°C.
Tape and reel packaging: –40°C to +80°C
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Temperature Coefficient of Inductance (TCL) +25 to +125 ppm/°C
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
One per billion hours / one billion hours, calculated per Telcordia SR-332
Packaging 600 per 7″ reel; 2200 per 13″ reel. Plastic tape: 12
mm wide, 0.3 mm thick, 8 mm pocket spacing, 3.7 mm pocket depth
PCB washing Tested with pure water or alcohol only. For other solvents,
see Doc787_PCB_Washing.pdf.
G
H
IJ
0.1950.1500.1350.0700.1000.0250.1280.1200.0450.118inches
4,953,813,431,782,540,643,253,051,143,00
mm
Note: Height dimension (C) is before optional solder application. For maximum
height dimension including solder, add 0.006 in / 0,152 mm.
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 730-1 Revised 03/27/12
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.
Document 730-2
Ultra High Q Chip Inductors – 1812
L vs Frequency
Q vs Frequency
1000
120
800
700
110
100
90
500
80
390 nH
400
Q Factor
Inductance (nH)
600
330 nH
300
270 nH
220 nH
200
70
60
150 nH
180 nH
220 nH
270 nH
330 nH
390 nH
50
40
180 nH
30
150 nH
20
10
100
1
100
10
1000
0
1
Frequency (MHz)
10
100
1000
Frequency (MHz)
Irms Derating
120
110
90
80
70
60
50
40
30
25°C
Percent of rated Irms
100
20
10
0
-40
-20
0
20
40
60
80
100
120 140
Ambient temperature (°C)
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 730-2 Revised 03/27/12
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.