PDF

The following document contains information on Cypress products.
S6SAL211A31SA2001
S6SAL211A31SA3001
Intelligent LED Lighting Starter Kit for DALI System
4ch 72W LED Driver Board and Communication Board
Operation Manual
Publication Number S6SAL211A31SA3001_SS405-00003
CONFIDENTIAL
Revision 1.0
Issue Date March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
Preface
This manual explains how to use the evaluation board. Be sure to read this manual before using the product.
For this product, please consult with sales representatives or support representatives.
Handling and Use
Handling and use of this product and notes regarding its safe use are described in the manuals.
Follow the instructions in the manuals to use this product.
Keep this manual at hand so that you can refer to it anytime during use of this product.
Notice on this Document
All information included in this document is current as of the date it is issued. Such information is subject to
change without any prior notice.
Please confirm the latest relevant information with the sales representatives.
2
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
Caution of the Products Described in this Document
The following precautions apply to the product described in this manual.
WARNING
WARNING
Electric shock,
Damage
Electric shock,
Damage
Indicates a potentially hazardous situation which could result in death or serious injury and/or a
fault in the user’s system if the product is not used correctly.
Do not look directly at LED. There is a possibility that your eye is hurt.
Before performing any operation described in this manual, turn off all the power supplies to the
system.
Performing such an operation with the power on may cause an electric shock or device fault.
Once the product has been turned on, do not touch any metal part of it.
Doing so may cause an electric shock or device fault.
Indicates the presence of a hazard that may cause a minor or moderate injury, damages to this
CAUTION
product or devices connected to it, or may cause to loose software resources and other
properties such as data, if the device is not used appropriately.
Before moving the product, be sure to turn off all the power supplies and unplug the cables.
Cuts, Damage
Watch your step when carrying the product. Do not use the product in an unstable location such
as a place exposed to strong vibration or a sloping surface. Doing so may cause the product to
fall, resulting in an injury or fault.
Cuts
The product contains sharp edges that are left unavoidably exposed, such as jumper plugs.
Handle the product with due care not to get injured with such pointed parts.
Do not place anything on the product or expose the product to physical shocks. Do not carry the
Damage
product after the power has been turned on.
Doing so may cause a malfunction due to overloading or shock.
Since the product contains many electronic components, keep it away from direct sunlight, high
Damage
temperature, and high humidity to prevent condensation. Do not use or store the product where
it is exposed to much dust or a strong magnetic or electric field for an extended period of time.
Inappropriate operating or storage environments may cause a fault.
Damage
Use the product within the ranges given in the specifications.
Operation over the specified ranges may cause a fault.
To prevent electrostatic breakdown, do not let your finger or other object come into contact with
Damage
the metal parts of any of the connectors. Before handling the product, touch a metal object
(such as a door knob) to discharge any static electricity from your body.
When turning the power on or off, follow the relevant procedure as described in this document.
Damage
Before turning the power on, in particular, be sure to finish making all the required connections.
Furthermore, be sure to configure and use the product by following the instructions given in this
document. Using the product incorrectly or inappropriately may cause a fault.
Because the product has no casing, it is recommended that it be stored in the original
Damage
packaging. Transporting the product may cause a damage or fault. Therefore, keep the
packaging materials and use them when re-shipping the product.
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
3
V1.1
O P E R A T I O N
M A N U A L
Table of Contents
1.
2.
3.
Description ..................................................................................................................................... 7
S6SAL211A31-DALI-SA2 Board Specification ............................................................................... 8
PIN Descriptions ............................................................................................................................. 8
3.1
Input/Output Connecter Descriptions .................................................................................. 8
3.2
Switch Descriptions ............................................................................................................. 8
4.
Setup and Verification .................................................................................................................... 9
4.1
Contents in a Package ........................................................................................................ 9
4.2
Evaluation with DALI Communication for S6SAL211A31SA3001 ..................................... 10
PC Setup for S6SATU03 .................................................................................. 10
4.2.1
4.2.2
Operation Check When Using S6SATU03 ........................................................ 11
4.2.3
GUI Control Function When Using S6SATU03 ................................................. 13
5.
Layout........................................................................................................................................... 21
5.1
S6SAL211A31-DALI-SA2 Component Layout .................................................................. 21
5.2
S6SAL211A31-DALI-SA2 Wiring Layout ........................................................................... 22
5.3
S6SATU03 Component Layout ......................................................................................... 24
6.
Circuit Schematic.......................................................................................................................... 25
6.1
S6SAL211A31-DALI-SA2 Schematic ................................................................................ 25
6.2
S6SATU03 Schematic....................................................................................................... 29
7.
Component List ............................................................................................................................ 30
7.1
S6SAL211A31-DALI-SA2 Components List ...................................................................... 30
7.2
S6SATU03 Components List ............................................................................................ 32
8.
S6SAL211A31-DALI-SA2 Property Data ...................................................................................... 33
9.
Board Picture ................................................................................................................................ 34
9.1
S6SAL211A31-DALI-SA2 Board Picture ........................................................................... 34
9.2
S6SATU03 Board Picture.................................................................................................. 35
10. Ordering Information..................................................................................................................... 36
11. Major Changes ............................................................................................................................. 36
Figures
Figure 1-1 DALI System Outline ................................................................................................................. 7
Figure 2-1 S6SAL211A31-DALI-SA2 Board Specification .......................................................................... 8
Figure 4-1 Contents Picture ....................................................................................................................... 9
Figure 4-2 Board Connection .................................................................................................................... 11
Figure 4-3 Connection of 6SAL211A31-DALI-SA2 and LED .................................................................... 12
Figure 5-1 S6SAL211A31-DALI-SA2 Component Layout ........................................................................ 21
Figure 5-2 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 1, Layer 2) .................................................... 22
Figure 5-3 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 3, Layer 4) .................................................... 23
Figure 5-4 S6SATU03 Component Layout ............................................................................................... 24
Figure 6-1 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 25
Figure 6-2 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 26
Figure 6-3 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 27
Figure 6-4 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 28
Figure 6-5 S6SATU03 DALI Communication Circuit ................................................................................ 29
Figure 8-1 Switching Waveform ............................................................................................................... 33
Figure 9-1 S6SAL211A31-DALI-SA2 Board Picture ................................................................................. 34
Figure 9-2 S6SATU03 Board Picture ........................................................................................................ 35
4
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
Tables
Table 3-1 S6SAL211A31-DALI-SA2 Input/Output Pin Descriptions ............................................................ 8
Table 3-2 S6SATU03 Input/Output Pin Descriptions .................................................................................. 8
Table 3-3 S6SAL211A31-DALI-SA2 Switch Descriptions ........................................................................... 8
Table 3-4 S6SATU03 Switch Descriptions .................................................................................................. 8
Table 4-1 S6SAL211A31SA3001 Contents List .......................................................................................... 9
Table 4-2 S6SAL211A31SA2001 Contents List .......................................................................................... 9
Table 7-1 S6SAL211A31-DALI-SA2 Components List ............................................................................. 30
Table 7-2 S6SATU03 DALI Communication Components List ................................................................. 32
Table 10-1 Ordering Information ............................................................................................................... 36
Table 11-1 Major Changes........................................................................................................................ 36
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
5
V1.1
O P E R A T I O N
6
CONFIDENTIAL
M A N U A L
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
S6SAL211A31SA2001
S6SAL211A31SA3001
Intelligent LED Lighting Starter Kit for DALI System
4ch 72W LED Driver Board and Communication Board
Operation Manual
1.
Description
S6SAL211A31SA2001 and S6SAL211A31SA3001 are starter kit tool for DALI communication system.
A master board (S6SATU03) and a slave board (S6SAL211A31-DALI-SA2) are included in
S6SAL211A31SA3001.
A slave board (S6SAL211A31-DALI-SA2) is included in S6SAL211A31SA2001.
Master board implements the communication circuits for DALI.
Slave board is LED control board of 4CH 72W for intelligent LED lighting driver IC S6AL211A31.
It is necessary to prepare a PC, 24V power supply, software, LED module and connection cable.
When using S6SAL211A31SA2001, please prepare DALI Master additionally.
Figure 1-1 DALI System Outline
PC
S6SATU03
USB cable
Master
GUI
Power
supply
24Vdc
S6SAL211A31-DALI-SA2
DALI
communication
cable
LED,Thermistor
Slave
S6SAL211A31SA2001
LED,Thermistor cable ×4ch
S6SAL211A31SA3001
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
7
V1.1
O P E R A T I O N
2.
M A N U A L
S6SAL211A31-DALI-SA2 Board Specification
Figure 2-1 S6SAL211A31-DALI-SA2 Board Specification
Item
Input voltage
Input current
(VIN = 24V, ACTUAL LEVEL = 254 (max.))
Input current
(VIN = 24V, LED OFF, Include LED001 indicator current (1.7 mA))
Output LED voltage
Output LED current
(Each channel, ACTUAL LEVEL = 254 (max.))
Efficiency
(VIN = 24V, ACTUAL LEVEL = 254 (max.))
Symbol
Min.
Typ.
Max.
Unit
VIN
22
24
26
V
IIN
-
3.1
-
A
IINoff
-
3
-
mA
VLEDout
0
18
VIN
V
ILEDout
-
1000
-
mA
η
-
95.8
-
%
The board size: 53 mm × 71.5 mm
POWE ON LEVEL: 0.4% (*1)
SYSTEM FAILRE LEVEL: 31% (*1)
*1: The specification of DALI is 100%, but it's changed because it's safe.
3.
PIN Descriptions
3.1
Input/Output Connecter Descriptions
Table 3-1 S6SAL211A31-DALI-SA2 Input/Output Pin Descriptions
Connecter Symbol
I/O
Function Description
CN_VIN
I
24Vdc power supply terminal
CN101,CN201,CN301,CN401
I/O
CH1 -CH4 LED , thermistor terminal
CN_DALI
I/O
DALI communication terminal
Table 3-2 S6SATU03 Input/Output Pin Descriptions
3.2
Connecter Symbol
I/O
CN101
I/O
Function Description
Mini USB connector
CN_DALI
I/O
DALI communication terminal
Switch Descriptions
Table 3-3 S6SAL211A31-DALI-SA2 Switch Descriptions
Switch
SW081
Description
DALI short address physical selection
Push in physical selection
Initial Setting
-
Table 3-4 S6SATU03 Switch Descriptions
8
CONFIDENTIAL
Switch
Description
Initial Setting
SW101
Reset push switch for MCU
-
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
4.
M A N U A L
Setup and Verification
4.1
Contents in a Package
Table 4-1 S6SAL211A31SA3001 Contents List
No.
Contents
Description
Quantity
Notes
1
S6SAL211A31-DALI-SA2
LED control board of 4CH 72W with S6AL211A31
1
-
2
S6SATU03
DALI and USB communication board with FM3
1
-
3
USB cable
USB to USB mini B cable
1
-
Table 4-2 S6SAL211A31SA2001 Contents List
No.
Contents
Description
Quantity
Notes
1
S6SAL211A31-DALI-SA2
LED control board of 4CH 72W with S6AL211A31
1
-
Figure 4-1 Contents Picture
1
2
3
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
9
V1.1
O P E R A T I O N
4.2
M A N U A L
Evaluation with DALI Communication for S6SAL211A31SA3001
2
Using Items for Evaluation with I C Control
 S6SAL211A31-DALI-SA2
 S6SATU03
 USB cable
 PC installed Windows7 or later OS
 Driver file
 DALI communication software
 24V power supply
 LED module(IF ≥ 1A, VF ≈ 3.2V, 5 series × 4ch)
 Connection cable
1pic (*1)
1pic (*1)
1pic (*1)
1pic (*2)
1pic (*3)
1pic (*3)
1pic (*2)
1set (*2)
1set (*2)
*1: Included in a package.
*2: Please prepare.
*3: Please download it from our device home page,
S6AL211A31:
Driver file
install.bat in S6AL211_DALI_drivers.cab
DALI communication software S6AL211_DALI_GUI.exe in S6AL211_DALI_GUI.cab
4.2.1
PC Setup for S6SATU03
1. Unpack the driver file to a folder of PC running Windows 7 or later version OS, and run install.bat file.
2. Connect S6SATU03 to PC using USB cable.
3. After installed a device, open the device manager and confirm the new COM port.
Start menu → Control panel → Device manager
4. PC Setup is success if you can see "SIL Virtual Communication Port(COMx)" in Ports(COM & LPT).
10
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
4.2.2
M A N U A L
Operation Check When Using S6SATU03
WARNING
Do not look directly at LED. There is a possibility that your eye is hurt.
1. Connect CN_101,201,301,401 of S6SAL211A31-DALI-SA2 and LED by connection cable. *1
2. Connect CN_DALI of S6SATU03 and CN_DALI of S6SAL211A31-DALI-SA2 by DALI cable. *2
3. Connect CN101 of S6SATU03 and PC by USB cable.
( LED101 near CN101 of S6SATU03 on board will shine in red. )
4. Run DALI communication software.
5. 24Vdc is applied to CN_VIN of S6SAL211A31-DALI-SA2.
6. LED of all channel are lighting. (Bright level is set POWER ON LEVEL of DALI command)
7. Send DALI command DAPC to BROADCAST ADDRESS from S6SATU03. You can control LED
brightness. (Look at "Control Lighting by the broadcast")
Figure 4-2 Board Connection
CN DALI
PC (*3)
S6SATU03
CN101
GUI
USB cable
Power
supply
24Vdc
CN_VIN
DALI
communication
line (*2)
(No Polarity)
CN DALI
CN_101
CN_201
CN_301
CN_401
LED,
Thermistor (*1)
S6SAL211A31-DALI-SA2
LED,Thermistor cable ×4ch
24Vdc
CN_VIN
CN DALI
CN_101
CN_201
CN_301
CN_401
S6SAL211A31-DALI-SA2 (*4)
Maximum DALI LIghting module (slave) number is 64.
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
11
V1.1
O P E R A T I O N
M A N U A L
*1: Connect LED to all CH from CN_101 to CN_401. Refer to Figure 4-3.
*2: S6SATU03 can provide power to DALI communication lines from CN_DALI. This current limit is
50 mA (Supply voltage = 12V-20V).We must consider this current when determining the number
of connected DALI Slave. We have to select the cable in consideration of the rated current and
then rated voltage
*3: Beforehand, make a setup of PC and install software.
*4: A board of S6SAL211A31-DALI-SA2 is possible to buy as single item.
(Part Number: S6SAL211A31SA2001)
Figure 4-3 Connection of 6SAL211A31-DALI-SA2 and LED
S6SAL211A31-DALI-SA2
CN_401
CN_301
CN_201
CN_101
LED,Thermistor
THm
THp
LEDm
LEDp
THm
THp
LEDm
LEDp
THm
THp
LEDm
LEDp
THm
THp
LEDm
LEDp
(*2)
(*1)
(*2)
(*1)
*1: Connect LED to all CH from CN_101 to CN_401. LED module(IF ≥ 1A, VF ≈ 3.2V, 5- series )
Be careful about polarity.
*2: Thermistor (THp,THm) is an option. Even if that isn't connected, a board operates.
12
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
4.2.3
M A N U A L
GUI Control Function When Using S6SATU03
4.2.3.1
Preparing the Control GUI
Run DALI communication software (S6AL211_DALI_GUI.exe) after connecting the USB cable.
Show the message box below if the connecting GUI and DALI controller is success.
Otherwise, check USB cable connection or installation of the device driver.
Later a few second, GUI shows the dialog box.
Complete preparation.
Note: Don't disconnect the USB cable while this GUI is running. Because it breaks down.
4.2.3.2
Exiting the Control GUI
Crick "×" mark in the upper right.
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
13
V1.1
O P E R A T I O N
4.2.3.3
M A N U A L
Checking State of the DALI Slave
You can check the state of connecting DALI slaves in "Management" tab.
Crick "SEARCH SHORT ADDRESS" button, then GUI will search some connected DALI slave.
If you see no highlighted number, Please refer to 4.2.3.6 Control Lighting by the Short Address.
And set the address.
GUI found 4 DALI slaves above picture.
Crick "CHECK STATUS" button, then GUI will show some connected DALI slave.
If you crick "CHECK STATUS" button after checking "Repeat" check box, this GUI will update status of DALI
slaves every second.
GUI shows you that 2 DALI slaves are bright above picture.
14
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
4.2.3.4
M A N U A L
Control Lighting by the Broadcast
DALI MASTER send to all connected DALI SLAVE by the broadcast in "control" tab.
(Selected "BroadCast" Radio button in "Address Select" Group)
Click Some Button and you can control lighting.
ON(Max) button:
Lighting starts at maximum level(default level 254).
ON(Min) button:
Lighting starts at minimum level(default level 1).
OFF button:
turn off lighting.
UP:
Increase lighting level at some pitch with fade.
DOWN:
reduce at some pitch with fade.
STEP UP:
One step up the lighting level.
STEP DOWN:
One step down the lighting level.
DAPC:
Direct Arc Power Control. Push this button after choosing the number (0-254) of the vertical
scrollbar.
Lighting level will set on the chosen number.
GO TO SCENE:
Set the lighting level to some scene after choosing number (0-15) of the drop box at left this button.
Show later for "SCENE".
Show below message box by selecting "Broadcast" radio button in "Address Select" group.
If you select "Yes", you can use "CHECK STATUS" button and "SCENE".
*Later mention: "CHECK STATUS", "SCENE". These functions by broadcast address can work correctly in
the case of connecting only one DALI slave
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
15
V1.1
O P E R A T I O N
4.2.3.5
M A N U A L
Control Lighting by the Group
DALI MASTER sends to each DALI group in "control" tab.
(Selected "Group" Radio button in "Address Select" Group)
Click Some Button and you can control lighting.
The operations of each button (ON, OFF, (STEP) UP, (STEP) DOWN, DAPC, SCENE function) are same in
broadcast.
Group setting method is shown in "For the Group" of "Control Lighting by the short address".
16
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
4.2.3.6
M A N U A L
Control Lighting by the Short Address
DALI MASTER send to the particular DALI SLAVE by the short address.
DALI SLAVE needs to choose short address number.
Crick "Short Address Setting" tab.
Push "SET SHORT ADDRESS" button after choosing from the drop box of left button.
Short address selection is completed.
Show blow window after choosing "Short Address" Radio button in "Address Select" Group
Choose the short address the drop box in "Address Select" group, and you can control he lighting that have
same short address.
CHECK STATUS: Show the status of DALI slave.
View Setting Panel: You can set SCENE, GROUP and each item by checking this check box. GUI will show
the dialog box below
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
17
V1.1
O P E R A T I O N
M A N U A L
Setting Panel Level, Fade, etc.
For the LEVEL
You can set each level from 1 to 254. (MAX LEVEL, MIN LEVEL, POWER ON LEVEL, SYSTEM FAILURE
LEVEL).
The fade time affects DAPC and SCENE. The fade rate affects UP and DOWN.
For the FADE
You can set the fade time and the fade rate.
The fade time affects DAPC and SCENE. The fade rate affects UP and DOWN.
Setting the FADE TIME
1. Select the fade time number (No fade-90.5sec) by drop box at left "SET FADE TIME" button.
2. Push "SET FADE TIME" button.
You can confirm in running the fade function as pushing "CHECK STATUS" button.
If DALI slave is in the fade function, "Fade Running" indicates "Running".
Setting the FAST FADE TIME
1. Select the fast fade time number (<25ms - 675msec) by drop box at left "SET FAST FADE TIME"
button with choosing No fade by SET FADE TIME.
2. Push "SET FAST FADE TIME" button.
Setting the FADE RATE
1. Select the fade time number (1-15) by drop box at left "SET FADE RATE" button.
2. Push "SET FADE RATE" button.
Select DIMMING CURVE
You can select dimming curve, Logarithm or linear
For the SCENE
You can set lighting level as scene from 0 to 15.
18
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
You can select lighting level in 1 action as choosing the scene number without using UP, DOWN, DPAC and
etc.
Using the SCENE
You can set 16 scenes lighting level by below window.
Example: Setting 125 in SCENE 2
1. Set Lighting level (0-254) to 125 by No. 2 Vscroll bar.
2. Select "2" scene number by drop box at left "STORE SCENE" button.
3. Push "STORE SCENE" button.
3
2
1
4. Select "2" scene number by drop box at left "GOTO SCENE" button.
5. Push "GO TO SCENE" button, then the lighting level will be set to 125.
5
4
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
19
V1.1
O P E R A T I O N
M A N U A L
For the GROUP
You can set lighting group from 0 to 15.
Example: Setting group to No.5.
1. Select "5" group number by drop box at left "ADD GROUP" button.
2. Push "ADD GROUP" button.
You can set group more than one for one DALI slave.
1
2
RESET Button
GUI shows "RESET" button with checking "View Setting Panel" check box.
You can reset DALI slave with pushing "RESET" button.
Note: This operation causes the lighting maximum level of LED.
Below each level are reset by "RESET" button.
(Example: MAX LEVEL=254, MIN LEVEL=1,
POWER ON LEVEL=254, SYSTEM FAILURE LEVEL=254
At the time of 6SAL211A31-DALI-SA2 shipment,
POWER ON LEVEL=1, SYSTEM FAILURE LEVEL=80)
20
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
5.
M A N U A L
Layout
5.1
S6SAL211A31-DALI-SA2 Component Layout
53mm
Figure 5-1 S6SAL211A31-DALI-SA2 Component Layout
71.5mm
53mm
S6SAL211A31-DALI-SA2 Top side (Top view)
71.5mm
S6SAL211A31-DALI-SA2 Bottom side (Top view)
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
21
V1.1
O P E R A T I O N
5.2
M A N U A L
S6SAL211A31-DALI-SA2 Wiring Layout
Figure 5-2 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 1, Layer 2)
S6SAL211A31-DALI-SA2 Layer 1 (Top view)
S6SAL211A31-DALI-SA2 Layer 2 (Top view)
22
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
Figure 5-3 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 3, Layer 4)
S6SAL211A31-DALI-SA2 Layer 3 (Top view)
S6SAL211A31-DALI-SA2 Layer 4 (Top view)
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
23
V1.1
O P E R A T I O N
5.3
M A N U A L
S6SATU03 Component Layout
50mm
Figure 5-4 S6SATU03 Component Layout
65mm
50mm
S6SATU03 Top side (Top view)
65mm
S6SATU03 Bottom side (Top view)
24
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
6. Circuit Schematic
6.1
S6SAL211A31-DALI-SA2 Schematic
Figure 6-1 S6SAL211A31-DALI-SA2 Circuit Schematic
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
25
V1.1
O P E R A T I O N
M A N U A L
Figure 6-2 S6SAL211A31-DALI-SA2 Circuit Schematic
26
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
Figure 6-3 S6SAL211A31-DALI-SA2 Circuit Schematic
CH1
CH2
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
27
V1.1
O P E R A T I O N
M A N U A L
Figure 6-4 S6SAL211A31-DALI-SA2 Circuit Schematic
CH3
CH4
28
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
6.2
M A N U A L
S6SATU03 Schematic
Figure 6-5 S6SATU03 DALI Communication Circuit
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
29
V1.1
O P E R A T I O N
M A N U A L
7. Component List
7.1
S6SAL211A31-DALI-SA2 Components List
Table 7-1 S6SAL211A31-DALI-SA2 Components List
No.
Component
1
2
3
4
Rated
Rated
Voltage(V)
Current(A)
-
200
500m
-
10 μF
35
-
-
4.7 μF
35
-
-
0.1 μF
50
-
-
TDK
4.7 μF
35
-
-
TDK
4.7 μF
35
-
-
C1608CH1H101J
TDK
100 pF
50
-
-
C1608CH1H101J
TDK
100 pF
50
-
-
Parts Number
Vendor
BD061
MB2S
FAIRCHILD
C001
C2012X5R1V106K125AC
TDK
C002
C1608X5R1V475K
TDK
C003
C1608X5R1H104K080AA
TDK
5
C004
C1608X5R1V475K
6
C005
C1608X5R1V475K
7
C006
8
C007
Value
Remarks
9
C009
EKMG350ELL101MF11D
NIPPON-CHEMI-CON
100 μF
35
-
-
10
C061
C3216X5R1V226M160AC
TDK
22 μF
35
-
-
11
C101-1
C3216X5R1V475K160AB
TDK
4.7 μF
35
-
-
12
C102-1
C3225X5R1H106K
TDK
10 μF
50
-
-
13
C102-3
C1608CH1H102J
TDK
0.001 μF
50
-
NMT
14
C120
C1608X5R1H104K080AA
TDK
0.1 μF
50
-
NMT
15
C201-1
C3216X5R1V475K160AB
TDK
4.7 μF
35
-
-
16
C202-1
C3225X5R1H106K
TDK
10 μF
50
-
-
17
C202-3
C1608CH1H102J
TDK
0.001 μF
50
-
NMT
18
C220
C1608X5R1H104K080AA
TDK
0.1 μF
50
-
NMT
19
C301-1
C3216X5R1V475K160AB
TDK
4.7 μF
35
-
-
20
C302-1
C3225X5R1H106K
TDK
10 μF
50
-
-
21
C302-3
C1608CH1H102J
TDK
0.001 μF
50
-
NMT
22
C320
C1608X5R1H104K080AA
TDK
0.1 μF
50
-
NMT
23
C401-1
C3216X5R1V475K160AB
TDK
4.7 μF
35
-
-
24
C402-1
C3225X5R1H106K
TDK
10 μF
50
-
-
25
C402-3
C1608CH1H102J
TDK
0.001 μF
50
-
NMT
26
C420
C1608X5R1H104K080AA
TDK
0.1 μF
50
-
NMT
27
CN101
ML-700-NH-4P
SATOPARTS
-
50
3
-
28
CN201
ML-700-NH-4P
SATOPARTS
-
50
3
-
29
CN301
ML-700-NH-4P
SATOPARTS
-
50
3
-
30
CN401
ML-700-NH-4P
SATOPARTS
-
50
3
-
31
CN_DALI
ML-2100-2P
SATOPARTS
-
300
7
-
32
CN_VIN
ML-2100-2P
SATOPARTS
-
300
7
-
33
D061
MBR140SFT1
ONSEMICONDUCTOR
-
30
500m
-
34
D101
SS23
FAIRCHILD
-
30
2
-
35
D201
SS23
FAIRCHILD
-
30
2
-
36
D301
SS23
FAIRCHILD
-
30
2
-
37
D401
SS23
FAIRCHILD
-
30
2
-
38
L101
SLF12575T-221M1R3
TDK
220 μH
-
1.3
-
39
L201
SLF12575T-221M1R3
TDK
220 μH
-
1.3
-
40
L301
SLF12575T-221M1R3
TDK
220 μH
-
1.3
-
41
L401
SLF12575T-221M1R3
TDK
220 μH
-
1.3
-
42
LED001
OSHR1608C1A
OptoSupply
-
-
30m
-
30
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
Rated
Rated
Voltage(V)
Current(A)
-
-
30m
NMT
No.
Component
Parts Number
Vendor
Value
43
LED061
OSTG1608C1A
OptoSupply
Remarks
44
M001
S6AL211A
SPANSION
-
-
-
-
45
PC061
PS2561L-1-A
CEL
-
-
-
-
CEL
-
-
-
-
46
PC062
PS2561L-1-A
47
Q061
FMMT491A
DIODES
-
40
1
-
48
Q101
FDC658AP
FAIRCHILD
-
30
4
-
49
Q102
FDC8886
FAIRCHILD
-
30
6.5
-
50
Q201
FDC658AP
FAIRCHILD
-
30
4
-
51
Q202
FDC8886
FAIRCHILD
-
30
6.5
-
30
4
-
52
Q301
FDC658AP
FAIRCHILD
-
53
Q302
FDC8886
FAIRCHILD
-
30
6.5
-
30
4
-
54
Q401
FDC658AP
FAIRCHILD
-
55
Q402
FDC8886
FAIRCHILD
-
30
6.5
-
56
R004
RR0816P-123-D
SSM
12 kΩ
-
-
-
57
R020
RR0816P-103-D
SSM
10 kΩ
-
-
-
-
-
58
R021
RR0816P-103-D
SSM
10 kΩ
-
59
R061
RR0816P-681-D
SSM
680Ω
-
-
-
-
-
60
R062
RR0816P-331-D
SSM
330Ω
-
61
R063
RR0816P-332-D
SSM
3.3 kΩ
-
-
-
62
R064
RK73H1JTTD4R70F
KOA
4.7Ω
-
-
-
63
R065
RR0816P-103-D
SSM
10 kΩ
-
-
-
-
-
64
R066
RR0816P-562-D
SSM
5.6 kΩ
-
65
R081
RR0816P-103-D
SSM
10 kΩ
-
-
NMT
-
-
66
R082
RR0816P-104-D
SSM
100 kΩ
-
67
R101
RL1632R-R200-F
SSM
200 mΩ
-
-
-
68
R103
RK73Z1J
KOA
0Ω
-
1
-
69
R104
RK73H1JTTD1004F
KOA
1 MΩ
-
-
NMT
-
NMT
70
R106
RK73H1JTTD1004F
KOA
1 MΩ
-
71
R107
RK73Z1J
KOA
0Ω
-
1
-
-
-
72
R120
RR0816P-752-D
SSM
7.5 kΩ
-
73
R201
RL1632R-R200-F
SSM
200 mΩ
-
-
-
74
R203
RK73Z1J
KOA
0Ω
-
1
-
75
R204
RK73H1JTTD1004F
KOA
1 MΩ
-
-
NMT
-
NMT
76
R206
RK73H1JTTD1004F
KOA
1 MΩ
-
77
R207
RK73Z1J
KOA
0Ω
-
1
-
-
-
78
R220
RR0816P-752-D
SSM
7.5 kΩ
-
79
R301
RL1632R-R200-F
SSM
200 mΩ
-
-
-
80
R303
RK73Z1J
KOA
0Ω
-
1
-
81
R304
RK73H1JTTD1004F
KOA
1 MΩ
-
-
NMT
-
NMT
82
R306
RK73H1JTTD1004F
KOA
1 MΩ
-
83
R307
RK73Z1J
KOA
0Ω
-
1
-
-
-
84
R320
RR0816P-752-D
SSM
7.5 kΩ
-
85
R401
RL1632R-R200-F
SSM
200 mΩ
-
-
-
86
R403
RK73Z1J
KOA
0Ω
-
1
-
87
R404
RK73H1JTTD1004F
KOA
1 MΩ
-
-
NMT
-
NMT
1
-
88
R406
RK73H1JTTD1004F
KOA
1 MΩ
-
89
R407
RK73Z1J
KOA
0Ω
-
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
31
V1.1
O P E R A T I O N
No.
Component
Parts Number
90
R420
91
SW081
92
ZD061
M A N U A L
Rated
Rated
Voltage(V)
Current(A)
Vendor
Value
Remarks
RR0816P-752-D
SSM
7.5 kΩ
-
-
-
SKRPACE010
ALPS
-
-
50m
-
MMSZ5229B
FAIRCHILD
-
-
-
-
NMT: No mount.
These components are compliant with RoHS, and please ask each vendor for details if necessary.
7.2
S6SATU03 Components List
Table 7-2 S6SATU03 DALI Communication Components List
No.
Component
Parts Number
1
C01
2
D01
3
D02
Rated
Rated
Voltage(V)
Current(A)
Vendor
Value
Remarks
C3216X5R1V226M160AC
TDK
22 μF
35
-
-
MBR140SFT1
ONSEMICONDUCTOR
-
30
500m
-
MBR140SFT1
ONSEMICONDUCTOR
-
30
500m
-
4
D14
MB2S
FAIRCHILD
-
200
500m
-
5
IC01
NJM317DL1
NJR
-
40
400m
-
6
LED_DALI
OSYG1608C1A
OptoSupply
-
-
30m
-
7
R01
RK73H2BTTD24R0F
KOA
24Ω
-
-
-
8
R02
RR0816P-153-D
SSM
15 kΩ
-
-
-
9
R03
RR0816P-681-D
SSM
680Ω
-
-
-
10
R04
RR0816P-331-D
SSM
330Ω
-
-
-
11
R05
RR0816P-332-D
SSM
3.3 kΩ
-
-
-
12
R06
RR0816P-562-D
SSM
5.6 kΩ
-
-
-
13
R07
RR0816P-562-D
SSM
5.6 kΩ
-
-
-
14
R08
RR0816P-103-D
SSM
10 kΩ
-
-
-
15
R09
RK73H1JTTD4R70F
KOA
4.7Ω
-
-
-
16
R10
RK73H2BTTD10R0F
KOA
10Ω
-
-
-
17
PC01
PS2561L-1-A
CEL
-
-
-
-
18
PC02
PS2561L-1-A
CEL
-
-
-
-
19
Q01
FMMT491A
DIODES
-
40
1
-
20
ZD01
MMSZ5229B
FAIRCHILD
4.3
-
-
-
21
ZD02
MMSZ5229B
FAIRCHILD
-
-
-
NMT
22
CN_DALI
ML-2100-2P
SATOPARTS
-
300
7
-
NMT: No mount.
These components are compliant with RoHS, and please ask each vendor for details if necessary.
32
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
8.
M A N U A L
S6SAL211A31-DALI-SA2 Property Data
Figure 8-1 Switching Waveform
CH1 100% Dimming
VIN=24V, ILEDout=1A
LED:LUW W5AM (5 series × 4ch)
ACTUAL LEVEL=254(Logarithm)
CH1: LED current (ILEDout)
CH2: LEDp voltage (VLEDout)
CH4: Switching node voltage
CH1 1% Dimming
VIN=24V, ILEDout=10 mA
LED:LUW W5AM (5 series × 4ch)
ACTUAL LEVEL=85(Logarithm)
CH1: LED current (ILEDout)
CH2: LEDp voltage (VLEDout)
CH4: Switching node voltage
CH1 0.1% Dimming
VIN=24V, ILEDout=1 mA
LED:LUW W5AM (5 series × 4ch)
ACTUAL LEVEL=1(Logarithm)
CH1: LED current (ILEDout)
CH2: LEDp voltage (VLEDout)
CH4: Switching node voltage
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
33
V1.1
O P E R A T I O N
M A N U A L
9. Board Picture
9.1
S6SAL211A31-DALI-SA2 Board Picture
Figure 9-1 S6SAL211A31-DALI-SA2 Board Picture
S6SAL211A31-DALI-SA2 (Top View)
S6SAL211A31-DALI-SA2 (Bottom View)
34
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
9.2
M A N U A L
S6SATU03 Board Picture
Figure 9-2 S6SATU03 Board Picture
S6SATU03 (Top View)
S6SATU03 (Bottom View)
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
35
V1.1
O P E R A T I O N
M A N U A L
10. Ordering Information
Table 10-1 Ordering Information
Part Number
EVB Revision
Note
S6SAL211A31-DALI-SA2 Rev1.0
S6SAL211A31SA3001
-
S6SATU03 Rev1.0
S6SAL211A31SA2001
S6SAL211A31-DALI-SA2 Rev1.0
-
11. Major Changes
Table 11-1 Major Changes
Page
Section
Change Results
Revision 1.0
-
36
CONFIDENTIAL
-
Initial release GUI Ver1.1
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015
v1.1
O P E R A T I O N
M A N U A L
SS405-00003-1v0-E
Spansion  Support Tool Manual
S6SAL211A31SA2001
S6SAL211A31SA3001
Intelligent LED Lighting Starter Kit for DALI System
4ch 72W LED Driver Board and Communication Board
Operation Manual
March 2015 Rev. 1.0
Published:
Edited:
Spansion Inc.
Communications
March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E
CONFIDENTIAL
37
V1.1
O P E R A T I O N
M A N U A L
Colophon
The products described in this document are designed, developed and manufactured as contemplated for general use,
including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not
designed, developed and manufactured as contemplated (1) for any use that includes fatal risks or dangers that, unless
extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury,
severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control,
mass transport control, medical life support system, missile launch control in weapon system), or (2) for any use where
chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Spansion will not be liable
to you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products.
Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such
failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and
prevention of over-current levels and other abnormal operating conditions. If any products described in this document
represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law
of Japan, the US Export Administration Regulations or the applicable laws of any other country, the prior authorization by the
respective government entity will be required for export of those products.
Trademarks and Notice
The contents of this document are subject to change without notice. This document may contain information on a Spansion
product under development by Spansion. Spansion reserves the right to change or discontinue work on any product without
notice. The information in this document is provided as is without warranty or guarantee of any kind as to its accuracy,
completeness, operability, fitness for particular purpose, merchantability, non-infringement of third-party rights, or any other
warranty, express, implied, or statutory. Spansion assumes no liability for any damages of any kind arising out of the use of
the information in this document.
®
®
®
TM
TM
Copyright © 2015 Cypress All rights reserved. Spansion , the Spansion logo, MirrorBit , MirrorBit Eclipse , ORNAND ,
TM
TM
Easy DesignSim , Traveo and combinations thereof, are trademarks and registered trademarks of Spansion LLC in the
United States and other countries. Other names used are for informational purposes only and may be trademarks of their
respective owners.
38
CONFIDENTIAL
S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015