The following document contains information on Cypress products. S6SAL211A31SA2001 S6SAL211A31SA3001 Intelligent LED Lighting Starter Kit for DALI System 4ch 72W LED Driver Board and Communication Board Operation Manual Publication Number S6SAL211A31SA3001_SS405-00003 CONFIDENTIAL Revision 1.0 Issue Date March 31, 2015 v1.1 O P E R A T I O N M A N U A L Preface This manual explains how to use the evaluation board. Be sure to read this manual before using the product. For this product, please consult with sales representatives or support representatives. Handling and Use Handling and use of this product and notes regarding its safe use are described in the manuals. Follow the instructions in the manuals to use this product. Keep this manual at hand so that you can refer to it anytime during use of this product. Notice on this Document All information included in this document is current as of the date it is issued. Such information is subject to change without any prior notice. Please confirm the latest relevant information with the sales representatives. 2 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L Caution of the Products Described in this Document The following precautions apply to the product described in this manual. WARNING WARNING Electric shock, Damage Electric shock, Damage Indicates a potentially hazardous situation which could result in death or serious injury and/or a fault in the user’s system if the product is not used correctly. Do not look directly at LED. There is a possibility that your eye is hurt. Before performing any operation described in this manual, turn off all the power supplies to the system. Performing such an operation with the power on may cause an electric shock or device fault. Once the product has been turned on, do not touch any metal part of it. Doing so may cause an electric shock or device fault. Indicates the presence of a hazard that may cause a minor or moderate injury, damages to this CAUTION product or devices connected to it, or may cause to loose software resources and other properties such as data, if the device is not used appropriately. Before moving the product, be sure to turn off all the power supplies and unplug the cables. Cuts, Damage Watch your step when carrying the product. Do not use the product in an unstable location such as a place exposed to strong vibration or a sloping surface. Doing so may cause the product to fall, resulting in an injury or fault. Cuts The product contains sharp edges that are left unavoidably exposed, such as jumper plugs. Handle the product with due care not to get injured with such pointed parts. Do not place anything on the product or expose the product to physical shocks. Do not carry the Damage product after the power has been turned on. Doing so may cause a malfunction due to overloading or shock. Since the product contains many electronic components, keep it away from direct sunlight, high Damage temperature, and high humidity to prevent condensation. Do not use or store the product where it is exposed to much dust or a strong magnetic or electric field for an extended period of time. Inappropriate operating or storage environments may cause a fault. Damage Use the product within the ranges given in the specifications. Operation over the specified ranges may cause a fault. To prevent electrostatic breakdown, do not let your finger or other object come into contact with Damage the metal parts of any of the connectors. Before handling the product, touch a metal object (such as a door knob) to discharge any static electricity from your body. When turning the power on or off, follow the relevant procedure as described in this document. Damage Before turning the power on, in particular, be sure to finish making all the required connections. Furthermore, be sure to configure and use the product by following the instructions given in this document. Using the product incorrectly or inappropriately may cause a fault. Because the product has no casing, it is recommended that it be stored in the original Damage packaging. Transporting the product may cause a damage or fault. Therefore, keep the packaging materials and use them when re-shipping the product. March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 3 V1.1 O P E R A T I O N M A N U A L Table of Contents 1. 2. 3. Description ..................................................................................................................................... 7 S6SAL211A31-DALI-SA2 Board Specification ............................................................................... 8 PIN Descriptions ............................................................................................................................. 8 3.1 Input/Output Connecter Descriptions .................................................................................. 8 3.2 Switch Descriptions ............................................................................................................. 8 4. Setup and Verification .................................................................................................................... 9 4.1 Contents in a Package ........................................................................................................ 9 4.2 Evaluation with DALI Communication for S6SAL211A31SA3001 ..................................... 10 PC Setup for S6SATU03 .................................................................................. 10 4.2.1 4.2.2 Operation Check When Using S6SATU03 ........................................................ 11 4.2.3 GUI Control Function When Using S6SATU03 ................................................. 13 5. Layout........................................................................................................................................... 21 5.1 S6SAL211A31-DALI-SA2 Component Layout .................................................................. 21 5.2 S6SAL211A31-DALI-SA2 Wiring Layout ........................................................................... 22 5.3 S6SATU03 Component Layout ......................................................................................... 24 6. Circuit Schematic.......................................................................................................................... 25 6.1 S6SAL211A31-DALI-SA2 Schematic ................................................................................ 25 6.2 S6SATU03 Schematic....................................................................................................... 29 7. Component List ............................................................................................................................ 30 7.1 S6SAL211A31-DALI-SA2 Components List ...................................................................... 30 7.2 S6SATU03 Components List ............................................................................................ 32 8. S6SAL211A31-DALI-SA2 Property Data ...................................................................................... 33 9. Board Picture ................................................................................................................................ 34 9.1 S6SAL211A31-DALI-SA2 Board Picture ........................................................................... 34 9.2 S6SATU03 Board Picture.................................................................................................. 35 10. Ordering Information..................................................................................................................... 36 11. Major Changes ............................................................................................................................. 36 Figures Figure 1-1 DALI System Outline ................................................................................................................. 7 Figure 2-1 S6SAL211A31-DALI-SA2 Board Specification .......................................................................... 8 Figure 4-1 Contents Picture ....................................................................................................................... 9 Figure 4-2 Board Connection .................................................................................................................... 11 Figure 4-3 Connection of 6SAL211A31-DALI-SA2 and LED .................................................................... 12 Figure 5-1 S6SAL211A31-DALI-SA2 Component Layout ........................................................................ 21 Figure 5-2 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 1, Layer 2) .................................................... 22 Figure 5-3 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 3, Layer 4) .................................................... 23 Figure 5-4 S6SATU03 Component Layout ............................................................................................... 24 Figure 6-1 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 25 Figure 6-2 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 26 Figure 6-3 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 27 Figure 6-4 S6SAL211A31-DALI-SA2 Circuit Schematic ........................................................................... 28 Figure 6-5 S6SATU03 DALI Communication Circuit ................................................................................ 29 Figure 8-1 Switching Waveform ............................................................................................................... 33 Figure 9-1 S6SAL211A31-DALI-SA2 Board Picture ................................................................................. 34 Figure 9-2 S6SATU03 Board Picture ........................................................................................................ 35 4 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L Tables Table 3-1 S6SAL211A31-DALI-SA2 Input/Output Pin Descriptions ............................................................ 8 Table 3-2 S6SATU03 Input/Output Pin Descriptions .................................................................................. 8 Table 3-3 S6SAL211A31-DALI-SA2 Switch Descriptions ........................................................................... 8 Table 3-4 S6SATU03 Switch Descriptions .................................................................................................. 8 Table 4-1 S6SAL211A31SA3001 Contents List .......................................................................................... 9 Table 4-2 S6SAL211A31SA2001 Contents List .......................................................................................... 9 Table 7-1 S6SAL211A31-DALI-SA2 Components List ............................................................................. 30 Table 7-2 S6SATU03 DALI Communication Components List ................................................................. 32 Table 10-1 Ordering Information ............................................................................................................... 36 Table 11-1 Major Changes........................................................................................................................ 36 March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 5 V1.1 O P E R A T I O N 6 CONFIDENTIAL M A N U A L S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 S6SAL211A31SA2001 S6SAL211A31SA3001 Intelligent LED Lighting Starter Kit for DALI System 4ch 72W LED Driver Board and Communication Board Operation Manual 1. Description S6SAL211A31SA2001 and S6SAL211A31SA3001 are starter kit tool for DALI communication system. A master board (S6SATU03) and a slave board (S6SAL211A31-DALI-SA2) are included in S6SAL211A31SA3001. A slave board (S6SAL211A31-DALI-SA2) is included in S6SAL211A31SA2001. Master board implements the communication circuits for DALI. Slave board is LED control board of 4CH 72W for intelligent LED lighting driver IC S6AL211A31. It is necessary to prepare a PC, 24V power supply, software, LED module and connection cable. When using S6SAL211A31SA2001, please prepare DALI Master additionally. Figure 1-1 DALI System Outline PC S6SATU03 USB cable Master GUI Power supply 24Vdc S6SAL211A31-DALI-SA2 DALI communication cable LED,Thermistor Slave S6SAL211A31SA2001 LED,Thermistor cable ×4ch S6SAL211A31SA3001 March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 7 V1.1 O P E R A T I O N 2. M A N U A L S6SAL211A31-DALI-SA2 Board Specification Figure 2-1 S6SAL211A31-DALI-SA2 Board Specification Item Input voltage Input current (VIN = 24V, ACTUAL LEVEL = 254 (max.)) Input current (VIN = 24V, LED OFF, Include LED001 indicator current (1.7 mA)) Output LED voltage Output LED current (Each channel, ACTUAL LEVEL = 254 (max.)) Efficiency (VIN = 24V, ACTUAL LEVEL = 254 (max.)) Symbol Min. Typ. Max. Unit VIN 22 24 26 V IIN - 3.1 - A IINoff - 3 - mA VLEDout 0 18 VIN V ILEDout - 1000 - mA η - 95.8 - % The board size: 53 mm × 71.5 mm POWE ON LEVEL: 0.4% (*1) SYSTEM FAILRE LEVEL: 31% (*1) *1: The specification of DALI is 100%, but it's changed because it's safe. 3. PIN Descriptions 3.1 Input/Output Connecter Descriptions Table 3-1 S6SAL211A31-DALI-SA2 Input/Output Pin Descriptions Connecter Symbol I/O Function Description CN_VIN I 24Vdc power supply terminal CN101,CN201,CN301,CN401 I/O CH1 -CH4 LED , thermistor terminal CN_DALI I/O DALI communication terminal Table 3-2 S6SATU03 Input/Output Pin Descriptions 3.2 Connecter Symbol I/O CN101 I/O Function Description Mini USB connector CN_DALI I/O DALI communication terminal Switch Descriptions Table 3-3 S6SAL211A31-DALI-SA2 Switch Descriptions Switch SW081 Description DALI short address physical selection Push in physical selection Initial Setting - Table 3-4 S6SATU03 Switch Descriptions 8 CONFIDENTIAL Switch Description Initial Setting SW101 Reset push switch for MCU - S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 4. M A N U A L Setup and Verification 4.1 Contents in a Package Table 4-1 S6SAL211A31SA3001 Contents List No. Contents Description Quantity Notes 1 S6SAL211A31-DALI-SA2 LED control board of 4CH 72W with S6AL211A31 1 - 2 S6SATU03 DALI and USB communication board with FM3 1 - 3 USB cable USB to USB mini B cable 1 - Table 4-2 S6SAL211A31SA2001 Contents List No. Contents Description Quantity Notes 1 S6SAL211A31-DALI-SA2 LED control board of 4CH 72W with S6AL211A31 1 - Figure 4-1 Contents Picture 1 2 3 March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 9 V1.1 O P E R A T I O N 4.2 M A N U A L Evaluation with DALI Communication for S6SAL211A31SA3001 2 Using Items for Evaluation with I C Control S6SAL211A31-DALI-SA2 S6SATU03 USB cable PC installed Windows7 or later OS Driver file DALI communication software 24V power supply LED module(IF ≥ 1A, VF ≈ 3.2V, 5 series × 4ch) Connection cable 1pic (*1) 1pic (*1) 1pic (*1) 1pic (*2) 1pic (*3) 1pic (*3) 1pic (*2) 1set (*2) 1set (*2) *1: Included in a package. *2: Please prepare. *3: Please download it from our device home page, S6AL211A31: Driver file install.bat in S6AL211_DALI_drivers.cab DALI communication software S6AL211_DALI_GUI.exe in S6AL211_DALI_GUI.cab 4.2.1 PC Setup for S6SATU03 1. Unpack the driver file to a folder of PC running Windows 7 or later version OS, and run install.bat file. 2. Connect S6SATU03 to PC using USB cable. 3. After installed a device, open the device manager and confirm the new COM port. Start menu → Control panel → Device manager 4. PC Setup is success if you can see "SIL Virtual Communication Port(COMx)" in Ports(COM & LPT). 10 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 4.2.2 M A N U A L Operation Check When Using S6SATU03 WARNING Do not look directly at LED. There is a possibility that your eye is hurt. 1. Connect CN_101,201,301,401 of S6SAL211A31-DALI-SA2 and LED by connection cable. *1 2. Connect CN_DALI of S6SATU03 and CN_DALI of S6SAL211A31-DALI-SA2 by DALI cable. *2 3. Connect CN101 of S6SATU03 and PC by USB cable. ( LED101 near CN101 of S6SATU03 on board will shine in red. ) 4. Run DALI communication software. 5. 24Vdc is applied to CN_VIN of S6SAL211A31-DALI-SA2. 6. LED of all channel are lighting. (Bright level is set POWER ON LEVEL of DALI command) 7. Send DALI command DAPC to BROADCAST ADDRESS from S6SATU03. You can control LED brightness. (Look at "Control Lighting by the broadcast") Figure 4-2 Board Connection CN DALI PC (*3) S6SATU03 CN101 GUI USB cable Power supply 24Vdc CN_VIN DALI communication line (*2) (No Polarity) CN DALI CN_101 CN_201 CN_301 CN_401 LED, Thermistor (*1) S6SAL211A31-DALI-SA2 LED,Thermistor cable ×4ch 24Vdc CN_VIN CN DALI CN_101 CN_201 CN_301 CN_401 S6SAL211A31-DALI-SA2 (*4) Maximum DALI LIghting module (slave) number is 64. March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 11 V1.1 O P E R A T I O N M A N U A L *1: Connect LED to all CH from CN_101 to CN_401. Refer to Figure 4-3. *2: S6SATU03 can provide power to DALI communication lines from CN_DALI. This current limit is 50 mA (Supply voltage = 12V-20V).We must consider this current when determining the number of connected DALI Slave. We have to select the cable in consideration of the rated current and then rated voltage *3: Beforehand, make a setup of PC and install software. *4: A board of S6SAL211A31-DALI-SA2 is possible to buy as single item. (Part Number: S6SAL211A31SA2001) Figure 4-3 Connection of 6SAL211A31-DALI-SA2 and LED S6SAL211A31-DALI-SA2 CN_401 CN_301 CN_201 CN_101 LED,Thermistor THm THp LEDm LEDp THm THp LEDm LEDp THm THp LEDm LEDp THm THp LEDm LEDp (*2) (*1) (*2) (*1) *1: Connect LED to all CH from CN_101 to CN_401. LED module(IF ≥ 1A, VF ≈ 3.2V, 5- series ) Be careful about polarity. *2: Thermistor (THp,THm) is an option. Even if that isn't connected, a board operates. 12 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 4.2.3 M A N U A L GUI Control Function When Using S6SATU03 4.2.3.1 Preparing the Control GUI Run DALI communication software (S6AL211_DALI_GUI.exe) after connecting the USB cable. Show the message box below if the connecting GUI and DALI controller is success. Otherwise, check USB cable connection or installation of the device driver. Later a few second, GUI shows the dialog box. Complete preparation. Note: Don't disconnect the USB cable while this GUI is running. Because it breaks down. 4.2.3.2 Exiting the Control GUI Crick "×" mark in the upper right. March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 13 V1.1 O P E R A T I O N 4.2.3.3 M A N U A L Checking State of the DALI Slave You can check the state of connecting DALI slaves in "Management" tab. Crick "SEARCH SHORT ADDRESS" button, then GUI will search some connected DALI slave. If you see no highlighted number, Please refer to 4.2.3.6 Control Lighting by the Short Address. And set the address. GUI found 4 DALI slaves above picture. Crick "CHECK STATUS" button, then GUI will show some connected DALI slave. If you crick "CHECK STATUS" button after checking "Repeat" check box, this GUI will update status of DALI slaves every second. GUI shows you that 2 DALI slaves are bright above picture. 14 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 4.2.3.4 M A N U A L Control Lighting by the Broadcast DALI MASTER send to all connected DALI SLAVE by the broadcast in "control" tab. (Selected "BroadCast" Radio button in "Address Select" Group) Click Some Button and you can control lighting. ON(Max) button: Lighting starts at maximum level(default level 254). ON(Min) button: Lighting starts at minimum level(default level 1). OFF button: turn off lighting. UP: Increase lighting level at some pitch with fade. DOWN: reduce at some pitch with fade. STEP UP: One step up the lighting level. STEP DOWN: One step down the lighting level. DAPC: Direct Arc Power Control. Push this button after choosing the number (0-254) of the vertical scrollbar. Lighting level will set on the chosen number. GO TO SCENE: Set the lighting level to some scene after choosing number (0-15) of the drop box at left this button. Show later for "SCENE". Show below message box by selecting "Broadcast" radio button in "Address Select" group. If you select "Yes", you can use "CHECK STATUS" button and "SCENE". *Later mention: "CHECK STATUS", "SCENE". These functions by broadcast address can work correctly in the case of connecting only one DALI slave March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 15 V1.1 O P E R A T I O N 4.2.3.5 M A N U A L Control Lighting by the Group DALI MASTER sends to each DALI group in "control" tab. (Selected "Group" Radio button in "Address Select" Group) Click Some Button and you can control lighting. The operations of each button (ON, OFF, (STEP) UP, (STEP) DOWN, DAPC, SCENE function) are same in broadcast. Group setting method is shown in "For the Group" of "Control Lighting by the short address". 16 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 4.2.3.6 M A N U A L Control Lighting by the Short Address DALI MASTER send to the particular DALI SLAVE by the short address. DALI SLAVE needs to choose short address number. Crick "Short Address Setting" tab. Push "SET SHORT ADDRESS" button after choosing from the drop box of left button. Short address selection is completed. Show blow window after choosing "Short Address" Radio button in "Address Select" Group Choose the short address the drop box in "Address Select" group, and you can control he lighting that have same short address. CHECK STATUS: Show the status of DALI slave. View Setting Panel: You can set SCENE, GROUP and each item by checking this check box. GUI will show the dialog box below March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 17 V1.1 O P E R A T I O N M A N U A L Setting Panel Level, Fade, etc. For the LEVEL You can set each level from 1 to 254. (MAX LEVEL, MIN LEVEL, POWER ON LEVEL, SYSTEM FAILURE LEVEL). The fade time affects DAPC and SCENE. The fade rate affects UP and DOWN. For the FADE You can set the fade time and the fade rate. The fade time affects DAPC and SCENE. The fade rate affects UP and DOWN. Setting the FADE TIME 1. Select the fade time number (No fade-90.5sec) by drop box at left "SET FADE TIME" button. 2. Push "SET FADE TIME" button. You can confirm in running the fade function as pushing "CHECK STATUS" button. If DALI slave is in the fade function, "Fade Running" indicates "Running". Setting the FAST FADE TIME 1. Select the fast fade time number (<25ms - 675msec) by drop box at left "SET FAST FADE TIME" button with choosing No fade by SET FADE TIME. 2. Push "SET FAST FADE TIME" button. Setting the FADE RATE 1. Select the fade time number (1-15) by drop box at left "SET FADE RATE" button. 2. Push "SET FADE RATE" button. Select DIMMING CURVE You can select dimming curve, Logarithm or linear For the SCENE You can set lighting level as scene from 0 to 15. 18 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L You can select lighting level in 1 action as choosing the scene number without using UP, DOWN, DPAC and etc. Using the SCENE You can set 16 scenes lighting level by below window. Example: Setting 125 in SCENE 2 1. Set Lighting level (0-254) to 125 by No. 2 Vscroll bar. 2. Select "2" scene number by drop box at left "STORE SCENE" button. 3. Push "STORE SCENE" button. 3 2 1 4. Select "2" scene number by drop box at left "GOTO SCENE" button. 5. Push "GO TO SCENE" button, then the lighting level will be set to 125. 5 4 March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 19 V1.1 O P E R A T I O N M A N U A L For the GROUP You can set lighting group from 0 to 15. Example: Setting group to No.5. 1. Select "5" group number by drop box at left "ADD GROUP" button. 2. Push "ADD GROUP" button. You can set group more than one for one DALI slave. 1 2 RESET Button GUI shows "RESET" button with checking "View Setting Panel" check box. You can reset DALI slave with pushing "RESET" button. Note: This operation causes the lighting maximum level of LED. Below each level are reset by "RESET" button. (Example: MAX LEVEL=254, MIN LEVEL=1, POWER ON LEVEL=254, SYSTEM FAILURE LEVEL=254 At the time of 6SAL211A31-DALI-SA2 shipment, POWER ON LEVEL=1, SYSTEM FAILURE LEVEL=80) 20 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 5. M A N U A L Layout 5.1 S6SAL211A31-DALI-SA2 Component Layout 53mm Figure 5-1 S6SAL211A31-DALI-SA2 Component Layout 71.5mm 53mm S6SAL211A31-DALI-SA2 Top side (Top view) 71.5mm S6SAL211A31-DALI-SA2 Bottom side (Top view) March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 21 V1.1 O P E R A T I O N 5.2 M A N U A L S6SAL211A31-DALI-SA2 Wiring Layout Figure 5-2 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 1, Layer 2) S6SAL211A31-DALI-SA2 Layer 1 (Top view) S6SAL211A31-DALI-SA2 Layer 2 (Top view) 22 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L Figure 5-3 S6SAL211A31-DALI-SA2 Wiring Layout (Layer 3, Layer 4) S6SAL211A31-DALI-SA2 Layer 3 (Top view) S6SAL211A31-DALI-SA2 Layer 4 (Top view) March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 23 V1.1 O P E R A T I O N 5.3 M A N U A L S6SATU03 Component Layout 50mm Figure 5-4 S6SATU03 Component Layout 65mm 50mm S6SATU03 Top side (Top view) 65mm S6SATU03 Bottom side (Top view) 24 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L 6. Circuit Schematic 6.1 S6SAL211A31-DALI-SA2 Schematic Figure 6-1 S6SAL211A31-DALI-SA2 Circuit Schematic March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 25 V1.1 O P E R A T I O N M A N U A L Figure 6-2 S6SAL211A31-DALI-SA2 Circuit Schematic 26 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L Figure 6-3 S6SAL211A31-DALI-SA2 Circuit Schematic CH1 CH2 March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 27 V1.1 O P E R A T I O N M A N U A L Figure 6-4 S6SAL211A31-DALI-SA2 Circuit Schematic CH3 CH4 28 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 6.2 M A N U A L S6SATU03 Schematic Figure 6-5 S6SATU03 DALI Communication Circuit March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 29 V1.1 O P E R A T I O N M A N U A L 7. Component List 7.1 S6SAL211A31-DALI-SA2 Components List Table 7-1 S6SAL211A31-DALI-SA2 Components List No. Component 1 2 3 4 Rated Rated Voltage(V) Current(A) - 200 500m - 10 μF 35 - - 4.7 μF 35 - - 0.1 μF 50 - - TDK 4.7 μF 35 - - TDK 4.7 μF 35 - - C1608CH1H101J TDK 100 pF 50 - - C1608CH1H101J TDK 100 pF 50 - - Parts Number Vendor BD061 MB2S FAIRCHILD C001 C2012X5R1V106K125AC TDK C002 C1608X5R1V475K TDK C003 C1608X5R1H104K080AA TDK 5 C004 C1608X5R1V475K 6 C005 C1608X5R1V475K 7 C006 8 C007 Value Remarks 9 C009 EKMG350ELL101MF11D NIPPON-CHEMI-CON 100 μF 35 - - 10 C061 C3216X5R1V226M160AC TDK 22 μF 35 - - 11 C101-1 C3216X5R1V475K160AB TDK 4.7 μF 35 - - 12 C102-1 C3225X5R1H106K TDK 10 μF 50 - - 13 C102-3 C1608CH1H102J TDK 0.001 μF 50 - NMT 14 C120 C1608X5R1H104K080AA TDK 0.1 μF 50 - NMT 15 C201-1 C3216X5R1V475K160AB TDK 4.7 μF 35 - - 16 C202-1 C3225X5R1H106K TDK 10 μF 50 - - 17 C202-3 C1608CH1H102J TDK 0.001 μF 50 - NMT 18 C220 C1608X5R1H104K080AA TDK 0.1 μF 50 - NMT 19 C301-1 C3216X5R1V475K160AB TDK 4.7 μF 35 - - 20 C302-1 C3225X5R1H106K TDK 10 μF 50 - - 21 C302-3 C1608CH1H102J TDK 0.001 μF 50 - NMT 22 C320 C1608X5R1H104K080AA TDK 0.1 μF 50 - NMT 23 C401-1 C3216X5R1V475K160AB TDK 4.7 μF 35 - - 24 C402-1 C3225X5R1H106K TDK 10 μF 50 - - 25 C402-3 C1608CH1H102J TDK 0.001 μF 50 - NMT 26 C420 C1608X5R1H104K080AA TDK 0.1 μF 50 - NMT 27 CN101 ML-700-NH-4P SATOPARTS - 50 3 - 28 CN201 ML-700-NH-4P SATOPARTS - 50 3 - 29 CN301 ML-700-NH-4P SATOPARTS - 50 3 - 30 CN401 ML-700-NH-4P SATOPARTS - 50 3 - 31 CN_DALI ML-2100-2P SATOPARTS - 300 7 - 32 CN_VIN ML-2100-2P SATOPARTS - 300 7 - 33 D061 MBR140SFT1 ONSEMICONDUCTOR - 30 500m - 34 D101 SS23 FAIRCHILD - 30 2 - 35 D201 SS23 FAIRCHILD - 30 2 - 36 D301 SS23 FAIRCHILD - 30 2 - 37 D401 SS23 FAIRCHILD - 30 2 - 38 L101 SLF12575T-221M1R3 TDK 220 μH - 1.3 - 39 L201 SLF12575T-221M1R3 TDK 220 μH - 1.3 - 40 L301 SLF12575T-221M1R3 TDK 220 μH - 1.3 - 41 L401 SLF12575T-221M1R3 TDK 220 μH - 1.3 - 42 LED001 OSHR1608C1A OptoSupply - - 30m - 30 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L Rated Rated Voltage(V) Current(A) - - 30m NMT No. Component Parts Number Vendor Value 43 LED061 OSTG1608C1A OptoSupply Remarks 44 M001 S6AL211A SPANSION - - - - 45 PC061 PS2561L-1-A CEL - - - - CEL - - - - 46 PC062 PS2561L-1-A 47 Q061 FMMT491A DIODES - 40 1 - 48 Q101 FDC658AP FAIRCHILD - 30 4 - 49 Q102 FDC8886 FAIRCHILD - 30 6.5 - 50 Q201 FDC658AP FAIRCHILD - 30 4 - 51 Q202 FDC8886 FAIRCHILD - 30 6.5 - 30 4 - 52 Q301 FDC658AP FAIRCHILD - 53 Q302 FDC8886 FAIRCHILD - 30 6.5 - 30 4 - 54 Q401 FDC658AP FAIRCHILD - 55 Q402 FDC8886 FAIRCHILD - 30 6.5 - 56 R004 RR0816P-123-D SSM 12 kΩ - - - 57 R020 RR0816P-103-D SSM 10 kΩ - - - - - 58 R021 RR0816P-103-D SSM 10 kΩ - 59 R061 RR0816P-681-D SSM 680Ω - - - - - 60 R062 RR0816P-331-D SSM 330Ω - 61 R063 RR0816P-332-D SSM 3.3 kΩ - - - 62 R064 RK73H1JTTD4R70F KOA 4.7Ω - - - 63 R065 RR0816P-103-D SSM 10 kΩ - - - - - 64 R066 RR0816P-562-D SSM 5.6 kΩ - 65 R081 RR0816P-103-D SSM 10 kΩ - - NMT - - 66 R082 RR0816P-104-D SSM 100 kΩ - 67 R101 RL1632R-R200-F SSM 200 mΩ - - - 68 R103 RK73Z1J KOA 0Ω - 1 - 69 R104 RK73H1JTTD1004F KOA 1 MΩ - - NMT - NMT 70 R106 RK73H1JTTD1004F KOA 1 MΩ - 71 R107 RK73Z1J KOA 0Ω - 1 - - - 72 R120 RR0816P-752-D SSM 7.5 kΩ - 73 R201 RL1632R-R200-F SSM 200 mΩ - - - 74 R203 RK73Z1J KOA 0Ω - 1 - 75 R204 RK73H1JTTD1004F KOA 1 MΩ - - NMT - NMT 76 R206 RK73H1JTTD1004F KOA 1 MΩ - 77 R207 RK73Z1J KOA 0Ω - 1 - - - 78 R220 RR0816P-752-D SSM 7.5 kΩ - 79 R301 RL1632R-R200-F SSM 200 mΩ - - - 80 R303 RK73Z1J KOA 0Ω - 1 - 81 R304 RK73H1JTTD1004F KOA 1 MΩ - - NMT - NMT 82 R306 RK73H1JTTD1004F KOA 1 MΩ - 83 R307 RK73Z1J KOA 0Ω - 1 - - - 84 R320 RR0816P-752-D SSM 7.5 kΩ - 85 R401 RL1632R-R200-F SSM 200 mΩ - - - 86 R403 RK73Z1J KOA 0Ω - 1 - 87 R404 RK73H1JTTD1004F KOA 1 MΩ - - NMT - NMT 1 - 88 R406 RK73H1JTTD1004F KOA 1 MΩ - 89 R407 RK73Z1J KOA 0Ω - March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 31 V1.1 O P E R A T I O N No. Component Parts Number 90 R420 91 SW081 92 ZD061 M A N U A L Rated Rated Voltage(V) Current(A) Vendor Value Remarks RR0816P-752-D SSM 7.5 kΩ - - - SKRPACE010 ALPS - - 50m - MMSZ5229B FAIRCHILD - - - - NMT: No mount. These components are compliant with RoHS, and please ask each vendor for details if necessary. 7.2 S6SATU03 Components List Table 7-2 S6SATU03 DALI Communication Components List No. Component Parts Number 1 C01 2 D01 3 D02 Rated Rated Voltage(V) Current(A) Vendor Value Remarks C3216X5R1V226M160AC TDK 22 μF 35 - - MBR140SFT1 ONSEMICONDUCTOR - 30 500m - MBR140SFT1 ONSEMICONDUCTOR - 30 500m - 4 D14 MB2S FAIRCHILD - 200 500m - 5 IC01 NJM317DL1 NJR - 40 400m - 6 LED_DALI OSYG1608C1A OptoSupply - - 30m - 7 R01 RK73H2BTTD24R0F KOA 24Ω - - - 8 R02 RR0816P-153-D SSM 15 kΩ - - - 9 R03 RR0816P-681-D SSM 680Ω - - - 10 R04 RR0816P-331-D SSM 330Ω - - - 11 R05 RR0816P-332-D SSM 3.3 kΩ - - - 12 R06 RR0816P-562-D SSM 5.6 kΩ - - - 13 R07 RR0816P-562-D SSM 5.6 kΩ - - - 14 R08 RR0816P-103-D SSM 10 kΩ - - - 15 R09 RK73H1JTTD4R70F KOA 4.7Ω - - - 16 R10 RK73H2BTTD10R0F KOA 10Ω - - - 17 PC01 PS2561L-1-A CEL - - - - 18 PC02 PS2561L-1-A CEL - - - - 19 Q01 FMMT491A DIODES - 40 1 - 20 ZD01 MMSZ5229B FAIRCHILD 4.3 - - - 21 ZD02 MMSZ5229B FAIRCHILD - - - NMT 22 CN_DALI ML-2100-2P SATOPARTS - 300 7 - NMT: No mount. These components are compliant with RoHS, and please ask each vendor for details if necessary. 32 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 8. M A N U A L S6SAL211A31-DALI-SA2 Property Data Figure 8-1 Switching Waveform CH1 100% Dimming VIN=24V, ILEDout=1A LED:LUW W5AM (5 series × 4ch) ACTUAL LEVEL=254(Logarithm) CH1: LED current (ILEDout) CH2: LEDp voltage (VLEDout) CH4: Switching node voltage CH1 1% Dimming VIN=24V, ILEDout=10 mA LED:LUW W5AM (5 series × 4ch) ACTUAL LEVEL=85(Logarithm) CH1: LED current (ILEDout) CH2: LEDp voltage (VLEDout) CH4: Switching node voltage CH1 0.1% Dimming VIN=24V, ILEDout=1 mA LED:LUW W5AM (5 series × 4ch) ACTUAL LEVEL=1(Logarithm) CH1: LED current (ILEDout) CH2: LEDp voltage (VLEDout) CH4: Switching node voltage March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 33 V1.1 O P E R A T I O N M A N U A L 9. Board Picture 9.1 S6SAL211A31-DALI-SA2 Board Picture Figure 9-1 S6SAL211A31-DALI-SA2 Board Picture S6SAL211A31-DALI-SA2 (Top View) S6SAL211A31-DALI-SA2 (Bottom View) 34 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N 9.2 M A N U A L S6SATU03 Board Picture Figure 9-2 S6SATU03 Board Picture S6SATU03 (Top View) S6SATU03 (Bottom View) March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 35 V1.1 O P E R A T I O N M A N U A L 10. Ordering Information Table 10-1 Ordering Information Part Number EVB Revision Note S6SAL211A31-DALI-SA2 Rev1.0 S6SAL211A31SA3001 - S6SATU03 Rev1.0 S6SAL211A31SA2001 S6SAL211A31-DALI-SA2 Rev1.0 - 11. Major Changes Table 11-1 Major Changes Page Section Change Results Revision 1.0 - 36 CONFIDENTIAL - Initial release GUI Ver1.1 S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1 O P E R A T I O N M A N U A L SS405-00003-1v0-E Spansion Support Tool Manual S6SAL211A31SA2001 S6SAL211A31SA3001 Intelligent LED Lighting Starter Kit for DALI System 4ch 72W LED Driver Board and Communication Board Operation Manual March 2015 Rev. 1.0 Published: Edited: Spansion Inc. Communications March 31, 2015, S6SAL211A31SA3001_SS405-00003-1v0-E CONFIDENTIAL 37 V1.1 O P E R A T I O N M A N U A L Colophon The products described in this document are designed, developed and manufactured as contemplated for general use, including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as contemplated (1) for any use that includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for any use where chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Spansion will not be liable to you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the US Export Administration Regulations or the applicable laws of any other country, the prior authorization by the respective government entity will be required for export of those products. Trademarks and Notice The contents of this document are subject to change without notice. This document may contain information on a Spansion product under development by Spansion. Spansion reserves the right to change or discontinue work on any product without notice. The information in this document is provided as is without warranty or guarantee of any kind as to its accuracy, completeness, operability, fitness for particular purpose, merchantability, non-infringement of third-party rights, or any other warranty, express, implied, or statutory. Spansion assumes no liability for any damages of any kind arising out of the use of the information in this document. ® ® ® TM TM Copyright © 2015 Cypress All rights reserved. Spansion , the Spansion logo, MirrorBit , MirrorBit Eclipse , ORNAND , TM TM Easy DesignSim , Traveo and combinations thereof, are trademarks and registered trademarks of Spansion LLC in the United States and other countries. Other names used are for informational purposes only and may be trademarks of their respective owners. 38 CONFIDENTIAL S6SAL211A31SA3001_SS405-00003-1v0-E, March 31, 2015 v1.1