G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay Surface-mounting, 1-GHz-Band/ 3-GHz-Band, Miniature, DPDT, High-frequency Relay • Superior high-frequency characteristics (at 1 GHz), such as an isolation of 20 dB min. between contacts of the same polarity or 30 dB min. between contacts of different polarity with an insertion loss of 0.2 dB max. • Miniaturized to 10.3 6.9 5.4 mm (L W H). • Rated power consumption of 100 mW with high sensitivity • Single-side stable and single-winding latching models available. • Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space. • G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint. • New PCB terminals models available. RoHS Compliant ■Model Number Legend ■Application Examples G 6 K@ -@ @ -@ -@ — —— — — 1 2 3 4 5 4. Special Function RF: High-frequency compatible G 6 K U ( )- 1. Relay Function None: Single-side stable U: Single-winding latching • Communications equipment • Broadcasting and audio-visual equipment • Test & measurement equipment 2 F P 2. Number of poles/ Contact Form 2: 2-pole/ DPDT (2c) ( )- 5. Terminal Shape None: Standard S: Small footprint T: Compatible with 3 GHz (- R F 3. Terminal Shape F: Outside-L surface mounting terminals P: PCB terminals S, ) T ■Ordering Information ●Standard Models with Surface-mounting Terminals Standard Specifications Relay Function Enclosure rating Contact form Fully sealed DPDT (2c) Enclosure rating Contact form Fully sealed DPDT (2c) Enclosure rating Contact form Fully sealed DPDT (2c) Enclosure rating Contact form Fully sealed DPDT (2c) Single-side stable Single-winding latching Rated coil voltage Minimum packing unit G6K-2F-RF Model 3, 4.5, 5, 12, 24 VDC G6KU-2F-RF 3, 4.5, 5, 12, 24 VDC 300 pcs/tray 300 pcs/reel Board space-saving model Relay Function Single-side stable Single-winding latching Rated coil voltage Minimum packing unit G6K-2F-RF-S Model 3, 4.5, 5, 12, 24 VDC G6KU-2F-RF-S 3, 4.5, 5, 12, 24 VDC 300 pcs/tray 300 pcs/reel Compatible with 3 GHz Relay Function Single-side stable Single-winding latching Rated coil voltage Minimum packing unit G6K-2F-RF-T Model 3, 4.5, 5, 12, 24 VDC G6KU-2F-RF-T 3, 4.5, 5, 12, 24 VDC 300 pcs/tray 300 pcs/reel Rated coil voltage Minimum packing unit 3, 4.5, 5, 12, 24 VDC 30 pcs/tube PCB terminals Relay Function Single-side stable Model G6K-2P-RF Note 1. When ordering, add the rated coil voltage to the model number. Example: G6K-2F-RF DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note 2. When ordering Relays in tape packing, add "-TR03" to the end of the model number. Example: G6K-2F-RF-TR03 DC3 Relays per reel: 300 pcs for -TR03 This specification, however, is not part of the relay model number, so it is not marked on the relay case. (If "-TR03" is not added to the end of the model number, the Relays will be provided in tray packing.) When ordering tape packing, minimum order unit is 1 reel (300 pcs ✕ 1 = 300 pcs). 1 G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay ■Ratings ●Coil: Single-side Stable (G6K-2F(P)-RF(-S, -T)) Item Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current (mA) Coil resistance () 33.0 23.2 21.1 9.1 4.6 91 194 237 1,315 5,220 Must operate voltage Must release voltage (V) (V) % of rated voltage 80% max. Maximum voltage (V) 10% min. 150% Must set voltage (V) Must reset voltage (V) % of rated voltage Maximum voltage (V) 75% max. 75% max. 150% Power consumption (mW) Approx. 100 ●Coil: Single-winding Latching Models (G6KU-2F-RF(-S, -T)) Item Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current (mA) Coil resistance () 33.0 23.2 21.1 9.1 4.6 91 194 237 1,315 5,220 Power consumption (mW) Approx. 100 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. ●Contacts Item G 6 K U Rated load Rated carry current Max. switching voltage Max. switching current ( )( )- 2 F P ●High-frequency Characteristics *1 Load * Resistive load 125 VAC, 0.3 A 30 VDC, 1 A 1 GHz, 1 W * 1A 125 VAC or 60 VDC 1A Model G6K(U)-2F(P)-RF(-S) Frequency 1GHz Between contacts of 20 dB min. the same polarity Isolation Between contacts of 30 dB min. different polarity Insertion loss 0.2 dB max. V.SWR 1.2 max. Maximum carry power 3W *2 Maximum switching power 1W *2 G6K(U)-2F-RF-T 1GHz 3GHz Item This value is for a V.SWR of 1.2 max. at the load. (- R F S, 20 dB min. 18 dB min. 30 dB min. 25 dB min. 0.2 dB max. 0.6 dB max. 1.2 max. 1.4 max. - Note 1. The impedance of the measurement system is 50 . Note 2. The above values are initial values. *1. Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics for the microload region. (Such applications include testing and measurement equipment and ATE applications.) *2. These values are for a V.SWR of 1.2 max. at the load. ) T ■Characteristics Relay Function Item Model Contact resistance *1 Operating (set) time *2 Release (reset) time *2 Minimum set/reset pulse time Insulation resistance *3 Between coil and contacts Between contacts of different polarity Dielectric strength Between contacts of the same polarity Between ground and coil/contacts Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Durability Electrical Ambient operating temperature Ambient operating humidity Weight Single-side stable models G6K-2F(P)-RF(-S, -T) 100 m max. 3 ms max. (approx. 1.4 ms) 3 ms max. (approx. 1.3 ms) --- Single-winding latching models G6KU-2F-RF(-S, -T) 3 ms max. (approx. 1.2 ms) 3 ms max. (approx. 1.2 ms) 10 ms 1,000 M min. (at 500 VDC) 750 VAC, 50/60 Hz for 1 min 750 VAC, 50/60 Hz for 1 min 750 VAC, 50/60 Hz for 1 min 500 VAC, 50/60 Hz for 1 min 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2 1,000 m/s2 750 m/s2 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour) 100,000 operations min. (at a switching frequency of 1,800 operations/hour) -40°C to 70°C (with no icing or condensation) 5% to 85% Approx. 0.95 g Note. The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. Values in parentheses are actual values. *3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. 2 G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay ■Engineering Data G6K-2F-RF Agile HP 8753D Vector Network Analyzer 50Ω terminaltion ●High-frequency Characteristics (Isolation) *1, *2 G6K-2F-RF Average value (initial) ●High-frequency Characteristics (Insertion Loss) *1, *2 G6K-2F-RF Average value (initial) ●High-frequency Characteristics (Return Loss, V.SWR) *1, *2 G6K-2F-RF Isolation (dB) Insertion loss (dB) Return loss (dB) HP8753D 0 Test subject: G6K-2F-RF 10 Number of Relays: 10 pcs 20 30 0 Test subject: G6K-2F-RF Number of Relays: 10 pcs 0.1 Average value (initial) 0.2 0 1.8 V · S 1.7 W R Test subject: G6K-2F-RF Number of Relays: 5 pcs 10 20 1.6 30 1.5 40 40 1.4 Return loss 50 0.3 70 60 0.4 80 1.2 V.SWR 1.1 70 0.5 90 0.5 1 1.5 2 2.5 0 3 0.5 1 1.5 2 Test subject: G6K-2F-RF-S 10 Number of Relays: 10 pcs 20 1 1.5 2 Average value (initial) 0 Test subject: G6K-2F-RF-S Number of Relays: 10 pcs 0.1 2.5 3 Frequency (GHz) G6K-2F-RF-S 0.2 0 Average value (initial) 1.8 V · S 1.7 W R Test subject: G6K-2F-RF-S Number of Relays: 5 pcs 10 20 1.6 30 1.5 40 1.4 R F S, 40 T ) Return loss 0.3 1.3 50 60 70 - 50 1.2 60 0.4 V.SWR 80 0.5 1 1.5 2 2.5 0 3 0.5 1 1.5 2 G6K-2F-RF-T N.O. N.C. Test subject: G6K-2F-RF-T Number of Relays: 5 pcs 10 G6K-2F-RF-T Insertion loss (dB) 0 Average value (initial) 20 30 2.5 80 3 1.0 0 0.5 1 1.5 2 Frequency (GHz) Frequency (GHz) 0.0 Average value (initial) N.O. N.C. Test subject: G6K-2F-RF-T Number of Relays: 5 pcs 0.2 0.4 2.5 3 Frequency (GHz) G6K-2F-RF-T Return loss (dB) 0 Isolation (dB) 1.1 70 0.5 90 0 Average value (initial) 2.6 V · S 2.4 W R N.O. N.C. Test subject: G6K-2F-RF-T Number of Relays: 5 pcs 10 20 2.2 30 2.0 40 40 0.6 V.SWR 60 1.4 0.8 1.2 70 80 90 1.6 50 60 70 1.8 Return loss 50 1.0 0 1 2 3 4 5 6 Frequency (GHz) 0 1 2 3 4 5 6 Frequency (GHz) 1.0 80 0 1 2 2 F P (- 30 0.5 ( )- Insertion loss (dB) G6K-2F-RF-S G 6 K U 1.0 0 ( )- Average value (initial) 0 80 3 Frequency (GHz) Frequency (GHz) G6K-2F-RF-S 2.5 Return loss (dB) 0 Isolation (dB) 1.3 50 60 3 4 5 6 Frequency (GHz) 3 G6K(U)-2F(P)-RF(-S, -T) Average value (initial) N.O. N.C. Test subject: G6K-2P-RF Number of Relays: 5 pcs 10 G6K-2P-RF 20 30 0.0 Average value (initial) N.O. N.C. Test subject: G6K-2P-RF Number of Relays: 5 pcs 0.1 G6K-2P-RF Return loss (dB) 0 Insertion loss (dB) Isolation (dB) G6K-2P-RF Surface-mounting High-frequency Relay 0 Average value (initial) 10 1.6 20 30 0.2 1.8 V · S 1.7 W R N.O. N.C. Test subject: G6K-2P-RF Number of Relays: 5 pcs 1.5 Return loss 40 1.4 40 50 V.SWR 0.3 50 1.3 60 1.2 70 1.1 60 70 0.4 80 90 0.5 0 0.5 1 1.5 2 2.5 0 3 0.5 1 1.5 2 Frequency (GHz) 2.5 80 3 1.0 0 0.5 1 1.5 2 2.5 3 Frequency (GHz) Frequency (GHz) Note. Refer to the G6K specifications for basic specifications not shown above. *1. Ambient temperature condition: 23°C *2. The high-frequency characteristics depend on the mounting board. Be sure to check operation including durability in actual equipment before use. ■Dimensions (Unit: mm) ( )- Standard Specifications G6K-2F-RF G G6KU-2F-RF 6 K U 2 F P 7.6 Orientation mark 5.4 3.2 12.8 10.3 0.6 8 ( )- 5.4 7 6 5 2 3 4 − 0.5 6.9 1.8 + 7 2.5 R F Terminal Arrangement/ Internal Connections (Top View) G6K-2F-RF Mounting Dimensions (Top View) Tolerance: ±0.1 mm 1 0.3 (- 0.5 1.35 S, 2.5 0.8 (1.35) 7.8 - 3.2 5.4 7.6 G6KU-2F-RF Orientation mark 1.95 8 11.5 7 6 5 3 4 − + SR + − ) T 1 Note 1. Each value has a tolerance of ±0.3 mm. Note 2. The coplanarity of the terminals is 0.15 mm max. 2 Note: Check carefully the coil polarity of the Relay. Board space-saving model 0.85 G6K-2F-RF-S G6KU-2F-RF-S 1.55 1.5 Mounting Dimensions (Top View) Tolerance: ±0.1 mm 0.85 G6K-2F-RF-S 8.8 Orientation mark 7.6 G6K-2F-RF-S VDC 10.7 10.3 0.6 5.4 7.8 8.6 1.2 1.6 JAPAN 5.4 3.2 8 7 6 5 2 3 4 − + 7.5 2.1 1.8 7 1 6.9 0.3 (1.35) 1 0.5 1.35 Terminal Arrangement/ Internal Connections (Top View) 0.8 1.8 G6KU-2F-RF-S Orientation mark 8 3.2 5.4 7.6 Note 1. Each value has a tolerance of ±0.3 mm. Note 2. The coplanarity of the terminals is 0.15 mm max. 7 6 5 3 4 − + SR + − 1 2 Note: Check carefully the coil polarity of the Relay. 4 G6K(U)-2F(P)-RF(-S, -T) Compatible with 3 GHz 0.85 G6K-2F-RF-T G6KU-2F-RF-T 0.5 Surface-mounting High-frequency Relay Terminal Arrangement/ Internal Connections (Top View) G6K-2F-RF-T Mounting Dimensions (Top View) Tolerance: ±0.1 mm 0.85 7.6 G6K-2F-RF-T -T RF -2FG6K 2VDC 1 7.8 8.6 VDC JAPAN 2.2 Orientation mark 5.4 3.2 8 1.1 4-1.15 1.35 7 6 5 2 3 4 − 2.2 + 4.8 10.7 10.3 1 7 10.8 1.1 6.9 4.8 G6KU-2F-RF-T Orientation mark 0.6 5.4 0.3 1.35 2.2 2.2 (2.45) 0.5 1.35 5.4 7.6 Note 1. Each value has a tolerance of ±0.3 mm. Note 2. The coplanarity of the terminals is 0.15 mm max. Note 3. The board dimensions are the dimensions that were used to measure the high-frequency characteristics given in the engineering data. The high-frequency characteristics and soldering conditions will depend on the type of board that is actually used. Always confirm applicability with the actual equipment before you use the Relay. G 6 K U 2 F P Orientation mark ( )- 6.9 1 2 3 4 R F − 5.08 0.5 0.4 (0.89) (0.3) 7 6 S, 5 - 0.15 8 (- + 2.54 12.7 T 5.08 ) 5.08 7.62 10.16 12.7 4 ( )- Twelve, 0.85-dia. holes 2.54 0.3 3 Terminal Arrangement/ Internal Connections (Bottom View) 5.5 max. 3.4 5 Note: Check carefully the coil polarity of the Relay. 2.54 13.3 10.4 2 1 PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm PCB terminals G6K-2P-RF 6 − + SR + − PCB information Layer Structure: 2L Finished Thickness: 0.6 mm Copper Thickness: 18 µm 3.2 7 8 14-0.8 Note: Check carefully the coil polarity of the Relay. Note. Each value has a tolerance of ±0.3 mm. 5 G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay ■Tube Packing and Tape Packing Specifications (1) Tube Packing 3. Carrier Tape Dimensions • G2K-2P-RF in tube packing are arranged so that the orientation mark of each Relay in on the left side. Fifty Relays are packed on one tube. Be sure not to make mistakes in Relay orientation when mounting the Relay to the PCB. Stopper (green) G6K(U)-2F-RF 1.5+0.1 0 dia. 5.9±0.1 12±1.0 4±0.1 2±0.1 A B 1.75±0.1 11.5±0.1 24±0.2 Stopper (gray) Orientation of Relays 0.4±0.1 13.4±0.1 10.9±0.1 0° 3°−1° B-B Cross Section B A 4.25±0.1 Tube length: 520 mm (stopper not included) No. of Relays per tube: 30 pcs 0° 3°−1° A-A Cross Section (2) Tape Packing (Surface Mounting Terminal Models) • Add “TR03” to the end of the model number to order Relays in tape packing. If “-TR03” is not added, the Relays will be provided in tray packing. Relays per reel: 300 pcs Minimun ordering unit:1 reel (300 relays) 8.5±0.1 G6K(U)-2F-RF-S(-T) 1.5+0.1 0 dia. 2±0.1 A B 1.75±0.1 11.3±0.1 ( )- 3° max. B A 2 F P Top tape (cover tape) 3° max. 9.2±0.1 ( )- A-A Cross Section R F (- Carrier tape Embossed tape S, ) Pulling Direction G6K(U)-2F-RF G6K(U)-2F-RF-S(-T) Orientation mark Orientation mark Pulling direction Pulling direction 2. Reel Dimensions 29.5±1 25.5±0.5 13±0.2 dia. 2±0.5 21±0.8 dia. A 330 80 R1 Enlarged View of Section A 6 0.4±0.05 11.5±0.1 24±0.3 G 6 1. Direction of Relay Insertion K U T 5.9±0.1 12±0.1 4±0.1 B-B Cross Section G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay ■G6K(U)-2F-RF(-S, -T) Recommended Soldering Method Temperature (°C) ●Recommended Conditions for IRS Method (Surface-mounting Terminals) • The thickness of cream solder to be applied should be (1) IRS Method (Mounting Solder: Lead) between 200 and 250 m and the land pattern should be based on OMRON’s recommended PCB pattern. • To maintain the correct soldering joint shown in the following diagram, we recommend applying solder with the soldering conditions shown on the left. Soldering 220~ 245 Correct Soldering 180~ 200 Incorrect Soldering Relay Terminal Land Preheating 150 Heel fillet is formed PCB Solder 90~120 Insufficient amount of solder Excessive amount of solder Check the soldering in the actual mounting conditions before use. 20~30 Time (s) (The temperature profile indicates the temperature on the circuit board sur- Temperature (°C) (2) IRS Method (Mounting Solder: Lead-free) Case top panel (peak): 255°C max. Soldering 250 max. G 6 K U 230 ( )- 180 ( )- 150 2 F P Preheating R F Relay terminal section (- 120 max. S, 30 max. - Time (s) (The temperature profile indicates the temperature on the PCB.) ) T 7 G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay ■Safety Precautions ●For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product Data Book. Correct Use ●Relay Handling • Use the Relay as soon as possible after opening the moistureproof package. (As a guideline, use the Relay within one week at 30°C or less and 60% RH or less.) If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and seal the package with adhesive tape. • When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent and keep the solvent temperature to less than 40°C. Do not put the Relay in a cold cleaning bath immediately after soldering. ●Environmental Conditions for Usage, Storage, and Transport • Avoid direct sunlight when using, storing, or transporting the Relay and maintain normal temperature, humidity, and pressure conditions. ●Long-term, Continuous ON Contacts ( )- G 6 K U ( )- 2 F P • Using the Relay in a circuit where the Relay will be ON continuously for long periods (rather than switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation and can cause a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend adding fail-safe circuits in case the contact fails or the coil burns out. (- R ●Claw Securing Force During Automatic Mounting F • During automatic insertion of Relays, be sure to set the securing force of each claw to the following so that the Relay’s characteristics will be maintained. S, T ) C A ●Coating • Do not use silicone coating to coat the Relay when it is mounted to the PCB. Do not wash the PCB after the Relay is mounted using detergent containing silicone. Otherwise, the detergent may remain on the surface of the Relay. ●Repeatability • Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics for the microload region. (Such applications include testing and measurement equipment and ATE applications.) ●About use of an IC socket. For: G6K-2P-RF • When using IC sockets, select IC sockets by confirming that the sockets Rated/Spec./Characteristics are within the range of using condition. Also, confirm whether there is any problem of electric capability or plug insertion or not with actual using condition. ●Others For: G6K-2P-RF • The dotted line below on the surface of relay is connected with a metal case (ground). So confirm the actual influence of insulation and signal characteristics when designing. 1 mm The dotted line is connected with a ground terminal. BOTTOM VIEW 1 mm A Ground terminal B Direction A: 1.96 N max. Direction B: 4.90 N max. Direction C: 1.96 N max. A’ Metal case Gap bettweeen a PCB and relay bottom Surface of a PCB 0.3 mm A-A’Cross Section Secure the claws to the shaded area. Do not attach them to the center of the Relay or just one part of the Relay. Metal case • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 8 Contact: www.omron.com/ecb Cat. No. K242-E1-05 0316(0207)(O)