Datasheet

G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
Surface-mounting, 1-GHz-Band/
3-GHz-Band, Miniature, DPDT,
High-frequency Relay
• Superior high-frequency characteristics (at 1 GHz), such as an isolation
of 20 dB min. between contacts of the same polarity or 30 dB min. between contacts of different polarity with an insertion loss of 0.2 dB max.
• Miniaturized to 10.3  6.9  5.4 mm (L  W  H).
• Rated power consumption of 100 mW with high sensitivity
• Single-side stable and single-winding latching models available.
• Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space.
• G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint.
• New PCB terminals models available.
RoHS Compliant
■Model Number Legend
■Application Examples
G 6 K@ -@ @ -@ -@
— —— — —
1
2 3
4
5
4. Special Function
RF: High-frequency compatible
G
6
K
U
( )-
1. Relay Function
None: Single-side stable
U: Single-winding latching
• Communications equipment
• Broadcasting and audio-visual equipment
• Test & measurement equipment
2
F
P
2. Number of poles/
Contact Form
2: 2-pole/ DPDT (2c)
( )-
5. Terminal Shape
None: Standard
S: Small footprint
T: Compatible with 3 GHz
(-
R
F
3. Terminal Shape
F: Outside-L surface mounting terminals
P: PCB terminals
S,
)
T
■Ordering Information
●Standard Models with Surface-mounting Terminals
Standard Specifications
Relay Function
Enclosure rating
Contact form
Fully sealed
DPDT
(2c)
Enclosure rating
Contact form
Fully sealed
DPDT
(2c)
Enclosure rating
Contact form
Fully sealed
DPDT
(2c)
Enclosure rating
Contact form
Fully sealed
DPDT (2c)
Single-side stable
Single-winding latching
Rated coil voltage
Minimum packing unit
G6K-2F-RF
Model
3, 4.5, 5, 12, 24 VDC
G6KU-2F-RF
3, 4.5, 5, 12, 24 VDC
300 pcs/tray
300 pcs/reel
Board space-saving model
Relay Function
Single-side stable
Single-winding latching
Rated coil voltage
Minimum packing unit
G6K-2F-RF-S
Model
3, 4.5, 5, 12, 24 VDC
G6KU-2F-RF-S
3, 4.5, 5, 12, 24 VDC
300 pcs/tray
300 pcs/reel
Compatible with 3 GHz
Relay Function
Single-side stable
Single-winding latching
Rated coil voltage
Minimum packing unit
G6K-2F-RF-T
Model
3, 4.5, 5, 12, 24 VDC
G6KU-2F-RF-T
3, 4.5, 5, 12, 24 VDC
300 pcs/tray
300 pcs/reel
Rated coil voltage
Minimum packing unit
3, 4.5, 5, 12, 24 VDC
30 pcs/tube
PCB terminals
Relay Function
Single-side stable
Model
G6K-2P-RF
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F-RF DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note 2. When ordering Relays in tape packing, add "-TR03" to the end of the model number.
Example: G6K-2F-RF-TR03 DC3
Relays per reel: 300 pcs for -TR03
This specification, however, is not part of the relay model number, so it is not marked on the relay case. (If "-TR03" is not added to the end of the model number,
the Relays will be provided in tray packing.)
When ordering tape packing, minimum order unit is 1 reel (300 pcs ✕ 1 = 300 pcs).
1
G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
■Ratings
●Coil: Single-side Stable (G6K-2F(P)-RF(-S, -T))
Item
Rated voltage
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
(mA)
Coil resistance
()
33.0
23.2
21.1
9.1
4.6
91
194
237
1,315
5,220
Must operate voltage Must release voltage
(V)
(V)
% of rated voltage
80% max.
Maximum voltage
(V)
10% min.
150%
Must set voltage
(V)
Must reset voltage
(V)
% of rated voltage
Maximum voltage
(V)
75% max.
75% max.
150%
Power consumption
(mW)
Approx. 100
●Coil: Single-winding Latching Models (G6KU-2F-RF(-S, -T))
Item
Rated voltage
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
(mA)
Coil resistance
()
33.0
23.2
21.1
9.1
4.6
91
194
237
1,315
5,220
Power consumption
(mW)
Approx. 100
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
●Contacts
Item
G
6
K
U
Rated load
Rated carry current
Max. switching voltage
Max. switching current
( )( )-
2
F
P
●High-frequency Characteristics *1
Load
*
Resistive load
125 VAC, 0.3 A
30 VDC, 1 A
1 GHz, 1 W *
1A
125 VAC or 60 VDC
1A
Model G6K(U)-2F(P)-RF(-S)
Frequency
1GHz
Between
contacts of
20 dB min.
the same
polarity
Isolation
Between
contacts of
30 dB min.
different
polarity
Insertion loss
0.2 dB max.
V.SWR
1.2 max.
Maximum carry power
3W *2
Maximum switching power 1W *2
G6K(U)-2F-RF-T
1GHz
3GHz
Item
This value is for a V.SWR of 1.2 max. at the load.
(-
R
F
S,
20 dB min. 18 dB min.
30 dB min. 25 dB min.
0.2 dB max. 0.6 dB max.
1.2 max.
1.4 max.
-
Note 1. The impedance of the measurement system is 50 .
Note 2. The above values are initial values.
*1.
Contact your OMRON representative if the Relay will be used in an
application that requires high repeatability in high-frequency
characteristics for the microload region. (Such applications include
testing and measurement equipment and ATE applications.)
*2.
These values are for a V.SWR of 1.2 max. at the load.
)
T
■Characteristics
Relay Function
Item
Model
Contact resistance *1
Operating (set) time *2
Release (reset) time *2
Minimum set/reset pulse time
Insulation resistance *3
Between coil and
contacts
Between contacts of
different polarity
Dielectric
strength
Between contacts of the
same polarity
Between ground and
coil/contacts
Destruction
Vibration
resistance
Malfunction
Destruction
Shock
resistance
Malfunction
Mechanical
Durability
Electrical
Ambient operating temperature
Ambient operating humidity
Weight
Single-side stable models
G6K-2F(P)-RF(-S, -T)
100 m max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.3 ms)
---
Single-winding latching models
G6KU-2F-RF(-S, -T)
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
10 ms
1,000 M min. (at 500 VDC)
750 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2
1,000 m/s2
750 m/s2
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
100,000 operations min. (at a switching frequency of 1,800 operations/hour)
-40°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 0.95 g
Note. The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. Values in parentheses are actual values.
*3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
2
G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
■Engineering Data
G6K-2F-RF
Agile HP 8753D
Vector Network
Analyzer
50Ω
terminaltion
●High-frequency Characteristics
(Isolation) *1, *2
G6K-2F-RF
Average value (initial)
●High-frequency Characteristics
(Insertion Loss) *1, *2
G6K-2F-RF
Average value (initial)
●High-frequency Characteristics
(Return Loss, V.SWR) *1, *2
G6K-2F-RF
Isolation (dB)
Insertion loss (dB)
Return loss (dB)
HP8753D
0
Test subject: G6K-2F-RF
10 Number of Relays: 10 pcs
20
30
0
Test subject: G6K-2F-RF
Number of Relays: 10 pcs
0.1
Average value (initial)
0.2
0
1.8 V
·
S
1.7 W
R
Test subject: G6K-2F-RF
Number of Relays: 5 pcs
10
20
1.6
30
1.5
40
40
1.4
Return loss
50
0.3
70
60
0.4
80
1.2
V.SWR
1.1
70
0.5
90
0.5
1
1.5
2
2.5
0
3
0.5
1
1.5
2
Test subject: G6K-2F-RF-S
10 Number of Relays: 10 pcs
20
1
1.5
2
Average value (initial)
0
Test subject: G6K-2F-RF-S
Number of Relays: 10 pcs
0.1
2.5
3
Frequency (GHz)
G6K-2F-RF-S
0.2
0
Average value (initial)
1.8 V
·
S
1.7 W
R
Test subject: G6K-2F-RF-S
Number of Relays: 5 pcs
10
20
1.6
30
1.5
40
1.4
R
F
S,
40
T
)
Return loss
0.3
1.3
50
60
70
-
50
1.2
60
0.4
V.SWR
80
0.5
1
1.5
2
2.5
0
3
0.5
1
1.5
2
G6K-2F-RF-T
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Relays: 5 pcs
10
G6K-2F-RF-T
Insertion loss (dB)
0
Average value (initial)
20
30
2.5
80
3
1.0
0
0.5
1
1.5
2
Frequency (GHz)
Frequency (GHz)
0.0
Average value (initial)
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Relays: 5 pcs
0.2
0.4
2.5
3
Frequency (GHz)
G6K-2F-RF-T
Return loss (dB)
0
Isolation (dB)
1.1
70
0.5
90
0
Average value (initial)
2.6 V
·
S
2.4 W
R
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Relays: 5 pcs
10
20
2.2
30
2.0
40
40
0.6
V.SWR
60
1.4
0.8
1.2
70
80
90
1.6
50
60
70
1.8
Return loss
50
1.0
0
1
2
3
4
5
6
Frequency (GHz)
0
1
2
3
4
5
6
Frequency (GHz)
1.0
80
0
1
2
2
F
P
(-
30
0.5
( )-
Insertion loss (dB)
G6K-2F-RF-S
G
6
K
U
1.0
0
( )-
Average value (initial)
0
80
3
Frequency (GHz)
Frequency (GHz)
G6K-2F-RF-S
2.5
Return loss (dB)
0
Isolation (dB)
1.3
50
60
3
4
5
6
Frequency (GHz)
3
G6K(U)-2F(P)-RF(-S, -T)
Average value (initial)
N.O.
N.C.
Test subject: G6K-2P-RF
Number of Relays: 5 pcs
10
G6K-2P-RF
20
30
0.0
Average value (initial)
N.O.
N.C.
Test subject: G6K-2P-RF
Number of Relays: 5 pcs
0.1
G6K-2P-RF
Return loss (dB)
0
Insertion loss (dB)
Isolation (dB)
G6K-2P-RF
Surface-mounting High-frequency Relay
0
Average value (initial)
10
1.6
20
30
0.2
1.8 V
·
S
1.7 W
R
N.O.
N.C.
Test subject: G6K-2P-RF
Number of Relays: 5 pcs
1.5
Return loss
40
1.4
40
50
V.SWR
0.3
50
1.3
60
1.2
70
1.1
60
70
0.4
80
90
0.5
0
0.5
1
1.5
2
2.5
0
3
0.5
1
1.5
2
Frequency (GHz)
2.5
80
3
1.0
0
0.5
1
1.5
2
2.5
3
Frequency (GHz)
Frequency (GHz)
Note. Refer to the G6K specifications for basic specifications not shown above.
*1. Ambient temperature condition: 23°C
*2. The high-frequency characteristics depend on the mounting board.
Be sure to check operation including durability in actual equipment before use.
■Dimensions
(Unit: mm)
( )-
Standard Specifications
G6K-2F-RF
G G6KU-2F-RF
6
K
U
2
F
P
7.6
Orientation mark
5.4
3.2
12.8
10.3
0.6
8
( )-
5.4
7
6
5
2
3
4
−
0.5
6.9
1.8
+
7
2.5
R
F
Terminal Arrangement/
Internal Connections
(Top View)
G6K-2F-RF
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
1
0.3
(-
0.5
1.35
S,
2.5
0.8
(1.35)
7.8
-
3.2
5.4
7.6
G6KU-2F-RF
Orientation mark
1.95
8
11.5
7
6
5
3
4
− +
SR
+ −
)
T
1
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.15 mm max.
2
Note: Check carefully the coil polarity of the Relay.
Board space-saving model
0.85
G6K-2F-RF-S
G6KU-2F-RF-S
1.55
1.5
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
0.85
G6K-2F-RF-S
8.8
Orientation mark
7.6
G6K-2F-RF-S
VDC
10.7
10.3
0.6
5.4
7.8
8.6
1.2
1.6
JAPAN
5.4
3.2
8
7
6
5
2
3
4
−
+
7.5
2.1
1.8
7
1
6.9
0.3
(1.35)
1
0.5
1.35
Terminal Arrangement/
Internal Connections
(Top View)
0.8
1.8
G6KU-2F-RF-S
Orientation mark
8
3.2
5.4
7.6
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.15 mm max.
7
6
5
3
4
− +
SR
+ −
1
2
Note: Check carefully the coil polarity of the Relay.
4
G6K(U)-2F(P)-RF(-S, -T)
Compatible with 3 GHz
0.85
G6K-2F-RF-T
G6KU-2F-RF-T
0.5
Surface-mounting High-frequency Relay
Terminal Arrangement/
Internal Connections
(Top View)
G6K-2F-RF-T
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
0.85
7.6
G6K-2F-RF-T
-T
RF
-2FG6K 2VDC
1
7.8
8.6
VDC JAPAN
2.2
Orientation mark
5.4
3.2
8
1.1
4-1.15
1.35
7
6
5
2
3
4
−
2.2
+
4.8
10.7
10.3
1
7
10.8
1.1
6.9
4.8
G6KU-2F-RF-T
Orientation mark
0.6
5.4
0.3
1.35
2.2 2.2
(2.45)
0.5
1.35
5.4
7.6
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.15 mm max.
Note 3. The board dimensions are the dimensions that were
used to measure the high-frequency characteristics
given in the engineering data.
The high-frequency characteristics and soldering conditions will depend on the type of board that is actually
used. Always confirm applicability with the actual
equipment before you use the Relay.
G
6
K
U
2
F
P
Orientation mark
( )-
6.9
1
2
3
4
R
F
−
5.08
0.5
0.4
(0.89)
(0.3)
7
6
S,
5
-
0.15
8
(-
+
2.54
12.7
T
5.08
)
5.08
7.62
10.16
12.7
4
( )-
Twelve, 0.85-dia. holes
2.54
0.3
3
Terminal Arrangement/
Internal Connections
(Bottom View)
5.5 max.
3.4
5
Note: Check carefully the coil polarity of the Relay.
2.54
13.3
10.4
2
1
PCB Mounting Holes (Bottom View)
Tolerance: ±0.1 mm
PCB terminals
G6K-2P-RF
6
− +
SR
+ −
PCB information
Layer Structure: 2L
Finished Thickness: 0.6 mm
Copper Thickness: 18 µm
3.2
7
8
14-0.8
Note: Check carefully the coil polarity of the Relay.
Note. Each value has a tolerance of ±0.3 mm.
5
G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
■Tube Packing and Tape Packing Specifications
(1) Tube Packing
3. Carrier Tape Dimensions
• G2K-2P-RF in tube packing are arranged so that the
orientation mark of each Relay in on the left side. Fifty Relays
are packed on one tube.
Be sure not to make mistakes in Relay orientation when
mounting the Relay to the PCB.
Stopper
(green)
G6K(U)-2F-RF
1.5+0.1
0 dia.
5.9±0.1
12±1.0
4±0.1
2±0.1
A
B
1.75±0.1
11.5±0.1
24±0.2
Stopper
(gray)
Orientation of Relays
0.4±0.1
13.4±0.1
10.9±0.1
0°
3°−1°
B-B Cross Section
B
A
4.25±0.1
Tube length: 520 mm (stopper not included)
No. of Relays per tube: 30 pcs
0°
3°−1°
A-A Cross Section
(2) Tape Packing (Surface Mounting Terminal Models)
• Add “TR03” to the end of the model number to order Relays in
tape packing.
If “-TR03” is not added, the Relays will be provided in tray
packing.
Relays per reel: 300 pcs
Minimun ordering unit:1 reel (300 relays)
8.5±0.1
G6K(U)-2F-RF-S(-T)
1.5+0.1
0 dia.
2±0.1
A
B
1.75±0.1
11.3±0.1
( )-
3° max.
B
A
2
F
P
Top tape
(cover tape)
3° max. 9.2±0.1
( )-
A-A Cross Section
R
F
(-
Carrier tape
Embossed tape
S,
)
Pulling Direction
G6K(U)-2F-RF
G6K(U)-2F-RF-S(-T)
Orientation mark
Orientation mark
Pulling
direction
Pulling
direction
2. Reel Dimensions
29.5±1
25.5±0.5
13±0.2 dia.
2±0.5
21±0.8 dia.
A
330
80
R1
Enlarged View of Section A
6
0.4±0.05
11.5±0.1
24±0.3
G
6 1. Direction of Relay Insertion
K
U
T
5.9±0.1
12±0.1
4±0.1
B-B Cross Section
G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
■G6K(U)-2F-RF(-S, -T) Recommended Soldering Method
Temperature (°C)
●Recommended Conditions for IRS Method (Surface-mounting Terminals)
• The thickness of cream solder to be applied should be
(1) IRS Method (Mounting Solder: Lead)
between 200 and 250 m and the land pattern should be
based on OMRON’s recommended PCB pattern.
• To maintain the correct soldering joint shown in the following
diagram, we recommend applying solder with the soldering
conditions shown on the left.
Soldering
220~
245
Correct Soldering
180~
200
Incorrect Soldering
Relay
Terminal
Land
Preheating
150
Heel fillet is
formed
PCB
Solder
90~120
Insufficient amount of solder
Excessive amount of solder
Check the soldering in the actual mounting conditions before use.
20~30
Time (s)
(The temperature profile indicates the temperature on the circuit board sur-
Temperature (°C)
(2) IRS Method (Mounting Solder: Lead-free)
Case top panel (peak):
255°C max.
Soldering
250 max.
G
6
K
U
230
( )-
180
( )-
150
2
F
P
Preheating
R
F
Relay terminal
section
(-
120 max.
S,
30 max.
-
Time (s)
(The temperature profile indicates the temperature on the PCB.)
)
T
7
G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
■Safety Precautions
●For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product
Data Book.
Correct Use
●Relay Handling
• Use the Relay as soon as possible after opening the
moistureproof package. (As a guideline, use the Relay within
one week at 30°C or less and 60% RH or less.) If the Relay is
left for a long time after opening the moisture-proof package,
the appearance may suffer and seal failure may occur after the
solder mounting process. To store the Relay after opening the
moisture-proof package, place it into the original package and
seal the package with adhesive tape.
• When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent and keep
the solvent temperature to less than 40°C. Do not put the
Relay in a cold cleaning bath immediately after soldering.
●Environmental Conditions for Usage, Storage, and
Transport
• Avoid direct sunlight when using, storing, or transporting the
Relay and maintain normal temperature, humidity, and
pressure conditions.
●Long-term, Continuous ON Contacts
( )-
G
6
K
U
( )-
2
F
P
• Using the Relay in a circuit where the Relay will be ON continuously
for long periods (rather than switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation
and can cause a film to develop on the contact surfaces. We
recommend using a latching relay (magnetic-holding relay) in this
kind of circuit. If a single-side stable model must be used in this kind
of circuit, we recommend adding fail-safe circuits in case the contact
fails or the coil burns out.
(-
R ●Claw Securing Force During Automatic Mounting
F • During automatic insertion of Relays, be sure to set the
securing force of each claw to the following so that the Relay’s
characteristics will be maintained.
S,
T
)
C
A
●Coating
• Do not use silicone coating to coat the Relay when it is
mounted to the PCB. Do not wash the PCB after the Relay is
mounted using detergent containing silicone. Otherwise, the
detergent may remain on the surface of the Relay.
●Repeatability
• Contact your OMRON representative if the Relay will be used
in an application that requires high repeatability in
high-frequency characteristics for the microload region. (Such
applications include testing and measurement equipment and
ATE applications.)
●About use of an IC socket.
For: G6K-2P-RF
• When using IC sockets, select IC sockets by confirming that
the sockets Rated/Spec./Characteristics are within the range
of using condition.
Also, confirm whether there is any problem of electric
capability or plug insertion or not with actual using condition.
●Others
For: G6K-2P-RF
• The dotted line below on the surface of relay is connected with
a metal case (ground).
So confirm the actual influence of insulation and signal
characteristics when designing.
1 mm
The dotted line is connected
with a ground terminal.
BOTTOM VIEW
1 mm
A
Ground terminal
B
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
A’
Metal case
Gap bettweeen a PCB and
relay bottom
Surface of a PCB
0.3 mm
A-A’Cross Section
Secure the claws to the shaded area. Do not attach them to the center of
the Relay or just one part of the Relay.
Metal case
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
8
Contact: www.omron.com/ecb
Cat. No. K242-E1-05
0316(0207)(O)