G5SB PCB Power Relay Compact Single-pole Relay for Switching 5 A • Compact SPDT Relay • Incorporates a normally open contact that switches 5 A max. (N.O. contacts) • Small, yet provides 8-kV impulse withstand voltage (between coil and contacts) • Standard model conforms to UL/CSA/VDE standards. RoHS Compliant ■Model Number Legend G5SB- 1 4 —— 1 2 1. Number of Poles 1: 1-pole/SPDT (1c) ■Application Examples 2. Enclosure rating 4: Fully sealed ■Ordering Information Model Minimum Rated coil packing voltage unit 5 VDC SPDT PCB (1c) terminals Standard Fully sealed G5SB-14 9 VDC 12 VDC 100 pcs/ Tray 24 VDC Note. When ordering, add the rated coil voltage to the model number. Example: G5SB-14 DC12 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. ■Ratings Rated voltage Must Must Max. operate release Rated Coil Power voltage current resistance voltage voltage consumption (V) (V) (V) (mA) (Ω) (mW) % of rated voltage 5 VDC 80 63 9 VDC 44.4 202 12 VDC 33.3 360 24 VDC 16.7 1,440 75% max. 5% min. 150% (at 23°C) Approx. 400 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ●Contacts Item Contact resistance *1 Operate time Release time Insulation resistance *2 Between coil and contacts Dielectric Between strength contacts of the same polarity Impulse Between coil withstand and contacts voltage Insulation Between coil distance and contacts Vibration resistance ●Coil Item Load Contact type Contact material Rated load Rated carry current G 5 S B ■Characteristics Contact Terminal Enclosure form Shape rating Classification • Ideal for output applications of control equipments Resistive load Single Ag-alloy (Cd free) 3 A (NO)/3 A (NC) at 125 VAC 5 A (NO)/3 A (NC) at 125 VAC 5 A (NO) at 250 VAC 3 A (NC) at 250 VAC 5 A (NO)/3 A (NC) at 30 VDC Shock resistance Destruction Malfunction Destruction Malfunction Mechanical Durability Electrical (resistive load) Failure rate (P level) (reference value) *3 Ambient operating temperature Ambient operating humidity Weight 100 mΩ max. 10 ms max. 5 ms max. 1,000 MΩ min. 4,000 VAC, 50/60 Hz for 1 min 1,000 VAC, 50/60 Hz for 1 min 8 kV (1.2 x 50 μs) Clearance: 3.5 mm, Creepage: 6.5 mm 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 100 m/s2 5,000,000 operations (18,000 operations per hour) 200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC 50,000 operations: 5 A (NO)/3 A (NC) at 125 VAC 50,000 operations: 5 A (NO) at 250 VAC 100,000 operations: 3 A (NC) at 250 VAC 100,000 operations: 5 A (NO)/3 A (NC) at 30 VDC Switching frequency: 1,800 operations per hour 10 mA at 5 VDC –40°C to 70°C with no icing or condensation 5% to 85% Approx. 6.5 g Note. The data shown above are initial values. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fallof-potential method. *2. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. *3. This value was measured at a switching frequency of 120 operations/min. 5 A (NO)/3 A (NC) Max. switching voltage 250 VAC, 30 VDC Max. switching current 5 A (NO)/3 A (NC) 1 G5SB PCB Power Relay ■Engineering Data ●Ambient Temperature vs. Maximum Voltage Maximum voltage (%) Switching current (A) ●Maximum Switching Capacity 7 AC resistive (NO) 6 5 4 DC resistive (NO) AC resistive (NC) 200 180 160 140 120 110 100 3 2 80 DC resistive (NC) 60 40 1 20 0 0 1 10 30 100 250 -40 1,000 -20 0 23 Switching voltage (V) G 5 S B Must operate/must release voltage (percentage of rated voltage) (%) ●Ambient Temperature vs Must Operate and Must Release Voltages Sample: 90 G2RL-14-E 24 VDC Number of Relays: 5 pcs 80 Must operate voltage Must release voltage 70 Note. The maximum voltage is the maximum voltage that can be applied to the relay cooil. 100 1,000 NO contact X 1,000 max. X min. 60 60 70 80 ●Shock Malfunction Y 100 40 Ambient temperature (°C) Z 1,000 NC contact 50 Sample: G5SB-14 12 VDC Number of Relays: 5 pcs Conditions: Shock is applied in ±X, ±Y, ±Z directions three times each with and without energizing the Relays to check the number of malfunctions. Requirement: None malfunction 100 m/s2 250 40 650 20 max. X min. 10 -30 -20 -10 1,000 X' 1,000 Z' 30 0 1,000 Y' Unit: m/s2 Shock direction X X' Y Z Z' 10 20 30 40 50 60 70 80 90 Y' Ambient temperature (°C) ■Dimensions (Unit: mm) G5SB-14 10.3max. (10.0)* 20.3max. (20.0)* Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 2.54 Five, 1.3±0.1-dia. holes (1.19) 2.54 15.8max. (15.5)* 1 5 0.4 10.16 3.4 1 0.27 5.08 2.54 (1.18) 7.62 *Values in parentheses are average values. ■Approved Standards UL Recognized: CSA Certified: Model G5SB (File No. E41515) (File No. LR31928) Coil ratings 12 to 24 VDC EN/IEC, VDE Certified: Contact ratings 5A 250V AC N.O. only (Resistive) 40°C 3A 125V AC N.O. only (Resistive) 40°C 5A 30V DC N.O. only (Resistive) 40°C 3A 250V AC N.C. only (Resistive) 40°C 2A 125V AC N.C. only (Resistive) 40°C Number of test operations 6,000 (Certificate No. 40003957) Model Coil ratings Contact ratings G5SB 12, 24 VDC 5A(N.O)/3A(N.C) 250V AC 70°C Number of test operations 10,000 ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. 2 2 3 7.62 0.4 10.16 5.08 2.54 4 (No coil polarity) G5SB PCB Power Relay G 5 S B · Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. · Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K122-E1-05 0316(0207)(O) 3