Datasheet

G5SB
PCB Power Relay
Compact Single-pole Relay for
Switching 5 A
• Compact SPDT Relay
• Incorporates a normally open contact that switches 5 A max.
(N.O. contacts)
• Small, yet provides 8-kV impulse withstand voltage (between coil
and contacts)
• Standard model conforms to UL/CSA/VDE standards.
RoHS Compliant
■Model Number Legend
G5SB- 1 4
——
1 2
1. Number of Poles
1: 1-pole/SPDT (1c)
■Application Examples
2. Enclosure rating
4: Fully sealed
■Ordering Information
Model
Minimum
Rated coil
packing
voltage
unit
5 VDC
SPDT
PCB
(1c) terminals
Standard
Fully
sealed
G5SB-14
9 VDC
12 VDC
100 pcs/
Tray
24 VDC
Note. When ordering, add the rated coil voltage to the model number.
Example: G5SB-14 DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
■Ratings
Rated
voltage
Must
Must
Max.
operate release
Rated
Coil
Power
voltage
current resistance voltage voltage
consumption
(V)
(V)
(V)
(mA)
(Ω)
(mW)
% of rated voltage
5 VDC
80
63
9 VDC
44.4
202
12 VDC
33.3
360
24 VDC
16.7
1,440
75%
max.
5% min.
150%
(at
23°C)
Approx. 400
Note 1. The rated current and coil resistance are measured at a coil
temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of
23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the
relay coil.
●Contacts
Item
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between coil
and contacts
Dielectric
Between
strength
contacts of the
same polarity
Impulse
Between coil
withstand
and contacts
voltage
Insulation
Between coil
distance
and contacts
Vibration
resistance
●Coil
Item
Load
Contact type
Contact material
Rated load
Rated carry current
G
5
S
B
■Characteristics
Contact Terminal Enclosure
form
Shape
rating
Classification
• Ideal for output applications of control equipments
Resistive load
Single
Ag-alloy (Cd free)
3 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO) at 250 VAC
3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC
Shock
resistance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Durability
Electrical
(resistive load)
Failure rate (P level)
(reference value) *3
Ambient operating
temperature
Ambient operating humidity
Weight
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min.
4,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
8 kV (1.2 x 50 μs)
Clearance: 3.5 mm, Creepage: 6.5 mm
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
1,000 m/s2
100 m/s2
5,000,000 operations
(18,000 operations per hour)
200,000 operations: 3 A (NO)/3 A (NC) at
125 VAC
50,000 operations: 5 A (NO)/3 A (NC) at
125 VAC
50,000 operations: 5 A (NO) at 250 VAC
100,000 operations: 3 A (NC) at 250 VAC
100,000 operations: 5 A (NO)/3 A (NC) at
30 VDC
Switching frequency: 1,800 operations per
hour
10 mA at 5 VDC
–40°C to 70°C with no icing or condensation
5% to 85%
Approx. 6.5 g
Note. The data shown above are initial values.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fallof-potential method.
*2. The insulation resistance is possible between coil and contacts and
between contacts of the same polarity at 500 VDC.
*3. This value was measured at a switching frequency of 120 operations/min.
5 A (NO)/3 A (NC)
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5 A (NO)/3 A (NC)
1
G5SB
PCB Power Relay
■Engineering Data
●Ambient Temperature vs.
Maximum Voltage
Maximum voltage (%)
Switching current (A)
●Maximum Switching Capacity
7
AC resistive
(NO)
6
5
4
DC resistive
(NO)
AC resistive
(NC)
200
180
160
140
120
110
100
3
2
80
DC resistive
(NC)
60
40
1
20
0
0
1
10
30
100
250
-40
1,000
-20
0
23
Switching voltage (V)
G
5
S
B
Must operate/must release voltage
(percentage of rated voltage) (%)
●Ambient Temperature vs Must
Operate and Must Release Voltages
Sample:
90 G2RL-14-E 24 VDC
Number of Relays: 5 pcs
80
Must operate voltage
Must release voltage
70
Note. The maximum voltage is the maximum
voltage that can be applied to the relay cooil.
100
1,000
NO contact
X
1,000
max.
X
min.
60
60 70 80
●Shock Malfunction
Y
100
40
Ambient temperature (°C)
Z
1,000
NC contact
50
Sample: G5SB-14 12 VDC
Number of Relays: 5 pcs
Conditions: Shock is applied in ±X, ±Y, ±Z
directions three times each with and without
energizing the Relays to check the number
of malfunctions.
Requirement: None malfunction 100 m/s2
250
40
650
20
max.
X
min.
10
-30 -20 -10
1,000
X'
1,000
Z'
30
0
1,000
Y'
Unit: m/s2
Shock direction
X
X'
Y
Z
Z'
10 20 30 40 50 60 70 80 90
Y'
Ambient temperature (°C)
■Dimensions (Unit: mm)
G5SB-14
10.3max.
(10.0)*
20.3max.
(20.0)*
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
2.54
Five, 1.3±0.1-dia. holes
(1.19)
2.54
15.8max.
(15.5)*
1
5
0.4
10.16
3.4
1
0.27
5.08
2.54
(1.18)
7.62
*Values in parentheses are average values.
■Approved Standards
UL Recognized:
CSA Certified:
Model
G5SB
(File No. E41515)
(File No. LR31928)
Coil ratings
12 to 24 VDC
EN/IEC, VDE Certified:
Contact ratings
5A 250V AC N.O. only (Resistive) 40°C
3A 125V AC N.O. only (Resistive) 40°C
5A 30V DC N.O. only (Resistive) 40°C
3A 250V AC N.C. only (Resistive) 40°C
2A 125V AC N.C. only (Resistive) 40°C
Number of test
operations
6,000
(Certificate No. 40003957)
Model
Coil ratings
Contact ratings
G5SB
12, 24 VDC
5A(N.O)/3A(N.C) 250V AC 70°C
Number of test
operations
10,000
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
2
2
3
7.62
0.4
10.16
5.08
2.54
4
(No coil polarity)
G5SB
PCB Power Relay
G
5
S
B
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K122-E1-05
0316(0207)(O)
3