G5NB-EL

G5NB-EL
PCB Power Relay
A slim compact Relay with 7 A
switching capacity
• 7 A (250 VAC), 5 A (30 VDC) high capacity switching with compact
size.
• Minimum 200,000 operations durability at 5 A (250 VAC) switching.
• IEC/EN 60335-1 conformed.
• Ambient operating temperature: max. 85°C
RoHS Compliant
■Model Number Legend
■Application Examples
• Home appliances
• Industrial equipment
• Building automation
G 5NB -@ @ @- @- @
——— — —
1 2 3
4
5
1. Number of Poles
1 : 1-pole
4. Classification
EL : High capacity and electrical
durability
2. Contact Form
A : SPST-NO (1a)
G
5
N
B
E
L
-
5. Conformity standard
HA : IEC/EN 60335-1 conformed
3. Enclosure rating
4 : Fully sealed
■Ordering Information
Classification
Single stable
relay
Item
Contact Enclosure rating
form
SPST-NO
(1a)
Fully Sealed
Model
Rated coil voltage
Minimum
packing unit
G5NB-1A4-EL-HA
12, 24 VDC
100 pcs/Tray
Note. When ordering, add the rated coil voltage to the model number.
Example: G5NB-1A4-EL-HA 12VDC
Rated coil voltage
■Ratings
●Coil
Item
Rated current
(mA)
Coil resistance
(Ω)
12 VDC
16.7
720
24 VDC
8.3
2,880
Rated voltage
Must operate voltage Must release voltage
(V)
(V)
Max. voltage
(V)
% of rated voltage
75% max.
10% min.
160% (at 23°C)
Power consumption
(mW)
Approx. 200
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
Item
Load
Contact Type
Contact material
Rated load
Rated carry current
Resistive load
Single
Ag-alloy (Cd free)
5 A at 250 VAC, 7 A at 250 VAC
5 A at 30 VDC
5 A at DC, 7 A at AC
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5 A at DC, 7 A at AC
1
G5NB-EL
PCB Power Relay
■Characteristics
Contact resistance *1
100 mΩ max.
Operate time
10 ms max.
Release time
10 ms max.
Insulation resistance *2
1,000 MΩ min.
Between coil and contacts
4,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
750 VAC, 50/60 Hz for 1 min
Insulation
distance
Between coil and contacts
Clearance: 5.5 mm, Creepage: 6 mm
Impulse
withstand
voltage
Between coil and contacts
10 kV (1.2 x 50 μs)
Dielectric
strength
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock
resistance
Destruction
1,000 m/s2
Malfunction
100 m/s2
Durability
Mechanical
5,000,000 operations min.
Electrical (resistive load)
200,000 operations at 250 VAC, 5 A
50,000 operations at 250 VAC, 7 A
100,000 operations at 30 VDC, 5 A
(with a rated load at 900 operations/h)
Failure rate (P level) (reference value) *3 DC5V 10mA
Ambient operating temperature
5% to 85%
Weight
Approx. 4 g
Note. The data shown above are initial value.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. This value was measured at a switching frequency of 120 operations/min.
■Engineering Data
●Maximum Switching Capacity
●Durability
10
100
AC resistive
load
5
DC resistive
load
Durability (104 operations)
Switching current (A)
7
1
50
1
10
30
100
250
30V DC resistive load
30
250V AC resistive load
10
0.1
5
3
1
1,000
0
1
2
3
4
Switching voltage (V)
200
No current
7A current
160
7
700
1,000
X
Energized
De-energized
1,000
Z'
Test Item: G5NB-1A4-EL-HA 24 VDC
Number of Relays: 5 pcs
Test Method: Shock was applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction was measured.
Rating: 100 m/s2
120
125
100
X'
1,000
Z
1,000
80
60
1,000
Y'
0
20 23
40
60
80 85
100
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
2
Y
1,000
140
40
6
●Shock malfunction
Test Item: G5NB-1A4-EL-HA 24 VDC
Number of Relays: 5 pcs.
180
5
Switching current (A)
●Ambient Temperature vs. Maximum Coil Voltage
Maximum coil voltage (%)
-
G
5
N
B
E
L
-40°C to 85°C (with no icing or condensation)
Ambient operating humidity
Unit: m/s2
Shock direction
X
X'
Y
Z
Z'
Y'
G5NB-EL
PCB Power Relay
■Dimensions
(Unit: mm)
G5NB-1A4-EL-HA
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
7.2max.
(7.0)*
20.5max.
(20.4)*
Terminal Arrangement/
Internal Connections
(Bottom View)
(1.05)
11.5
15.3max.
(15.0)*
(1.15)
7
Four, 1.1 dia.
1
2
3
4.7
4
3.4
@0.4
0.27
11.5
0.33
(No coil polarity)
0.8
7
4.7
*Average value
■Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●UL Recognized:
(File No. E41515)
(File No. LR31928)
CSA Certified:
Model
Contact form
Coil ratings
G5NB-1A4-EL-HA
SPST-NO
(1a)
12 to 24V DC
Number of test
operations
7A 250V AC (General Purpose) 85°C
30,000
5A 250V AC (General Purpose) 85°C
50,000
5A 30V DC (Resistive) 85°C
6,000
G
5
N
B
E
L
(Registration No. 137575)
Model
Contact form
Coil ratings
G5NB-1A4-EL-HA
SPST-NO
(1a)
12, 24V DC
Contact ratings
7A 250V AC (Resistive) 85°C
5A 30V DC (Resistive) 85°C
-
●EN/IEC, VDE Certified
Contact ratings
Number of test
operations
10,000
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
3
G5NB-EL
PCB Power Relay
-
G
5
N
B
E
L
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. K270-E1-01
0914(0207)(O)