PCB Relay G5Q Compact, High Isolation Relay • Compact single pole relay with high isolation between coil and contacts. • Ensures a withstand impulse voltage of 8,000V between the coil and contacts. • Low coil power consumption. • UL class F coil insulation. • UL recognized / CSA certified. EN approved. • Ideal for appliance and HVAC controls • RoHS Compliant Ordering Information To Order: Select the part number and add the desired coil voltage and rating. (e.g., G5Q-14 DC12) Classification Single contact, class F coil insulation SPST-NO SPDT Enclosure rating Model Flux protection G5Q-1A Fully-sealed G5Q-1A4 Flux protection G5Q-1 Fully-sealed G5Q-14 Note: Add “-EU” before the coil voltage to obtain versions with CTI > 250. (e.g., G5Q-1A4-EU DC12) Specifications for "EU" type differ from standard models. Contact Omron for more details Specifications ■ Coil Ratings Rated voltage (V) SPDT SPST-NO Rated coil current (mA) Coil resistance (Ω) DC 5 80 63 DC 9 44.4 202 DC 12 33.3 360 DC 24 16.7 1440 DC 5 40 125 DC 9 22.2 405 DC 12 16.7 720 DC 24 8.3 2880 Pick-up voltage Drop-out voltage Maximum voltage Power consumption (mW) Percent of rated voltage 75% max 5% min 190% @ 23°C 400 200 Note: 1. Rated current and coil resistance are measured at 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The “Maximum voltage” is the maximum voltage that can be applied to the relay coil. PCB Relay G5Q 1 ■ Contact Ratings Item Rated load (resistive) SPDT 10 A at 125 VAC (NO) 3 A at 250 VAC (NO) 3 A at 125 VAC (NO) 5 A at 30 VDC (NO) 3 A at 250 VAC (NC) 3 A at 125 VAC (NC) 3 A at 30 VDC (NC) Single Ag alloy (Cd free) 10 A (NO)/3 A (NC) 277 VAC, 30 VDC AC: 10 A (NO)/3 A (NC) DC: 5 A (NO)/3 A (NC) 1250 VA, 150 W (NO) 750 VA, 90 W (NC) Contact type Contact material Rated carry current Max. switching voltage Max. switching current Max. switching capacity Min. permissible load (120 operations/minute) SPST-NO 10 A at 125 VAC 3 A at 250 VAC 3 A at 125 VAC 5 A at 30 VDC 10 mA at 5 VDC (P level: λ60 = 0.1 × 10−6/operation) ■ Characteristics Contact resistance (See note 2.) Operate time Release time Insulation resistance (See note 3.) Dielectric strength Impulse withstand voltage Vibration resistance Shock resistance Life expectancy (See Note 4) Mechanical Electrical 100 mΩ max. 10 ms max. 5 ms max. 1,000 mΩ min. 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 8 kV (1.2 × 50 μs) between coil and contacts Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction: 1000 m/s2 (approx. 100G) Malfunction: 100 m/s2 (approx. 10G) 10,000,000 operations (18,000 operations per hour) NO 50,000 operations: 10 A at 125 VAC resistive load (operations: ON for 1 sec, OFF for 3 sec.) 200,000 operations: 3 A at 125 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.) 100,000 operations: 3 A at 250 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.) 100,000 operations: 5 A at 30 VDC resistive load (operations: ON for 1 sec, OFF for 1 sec.) NC 200,000 operations: 3 A at 125 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.) 100,000 operations: 3 A at 250 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.) 100,000 operations: 3 A at 30 VDC resistive load (operations: ON for 1 sec, OFF for 1 sec.) Ambient temperature Operating & storage −40°C to 105°C with no icing or condensation Ambient humidity Operating & storage 5% to 85% Weight Note: 1. 2. 3. 4. 2 Approx. 6.5 g The data shown above are initial values. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. The electrical life data items shown are possible at 23°C PCB Relay G5Q ■ Approved Standard UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp = 40°C Model Contact Form Coil ratings Number of test operations Contact ratings 10 A 250 VAC N.O. only (resistive) 6,000 10 A 30 VDC N.O. only (resistive) SPST-NO (1a) SPDT (1c) G5Q 5 to 48 VDC 4 A 120 VAC N.O. only (resistive) 100,000 3 A 250 VAC N.C. only (resistive) 6,000 3 A 30 VDC N.O. only (resistive) EC/IEC, VDE (Certified / No.40003467) - - Ambient Temp = 105°C Model Contact Form Coil ratings Contact ratings Number of test operations G5Q SPST-NO (1a) SPDT (1c) 5, 9, 12, 24 VDC 10 A 250 VAC (cosφ=1)(N.O.) 5 A 30 VDC (0 ms)(N.O.) 3 A 30 VDC (0 ms)(N.C.) 10,000 Engineering Data Switching current (A) 100 AC resistive load (NO) 10 DC resistive load (NO) AC resistive load (NC) Maximum coil voltage (% of rated) Ambient Temperature vs Maximum Coil Voltage Maximum Switching Capacity Shock Malfunction 200 Y 1,000 180 160 X 1,000 140 Z 1,000 120 100 NC NO Contact 300 Contact 80 300 1,000 Z 60 1,000 X 40 DC resistive load (NC) 20 1,000 Y 1 1 10 100 1000 Switching voltgate (V) 0 -40 -20 0 20 23 40 60 80 85 100 120 Ambient temperature (°C) Unit: m/s2 Sample: G5Q-14 DC12 Shock direction Number of Relays: 5 pcs X X Y Test Conditions: Shock is applied Z in ±X, ±Y and ±Z directions three times each with without Z energizing the Relays to check Y the number of malfunctions. Requirements: None malfunction 100 m/s2 PCB Relay G5Q 3 Dimensions Note: All units are in millimeters unless otherwise indicated. G5Q-1A G5Q-1A4 PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* . (1.18) ± 1.3 0.1 dia 4- (1.19) 1 0.27 MAX (No coil polarity) 10.16±0.1 1 0.4 x 0.4 7.62 10.16 * Average value 7.62 G5Q-1 G5Q-14 PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* (1.18) . .3 5-1 .1 ±0 (1.19) 15.8MAX (15.5)* 0.4 3.4 0.4 x 0.4 3 5 7.62±0.1 3.4 2 7.62±0.1 15.8MAX (15.5)* 0.4 Terminal Arrangement/ Internal Connections (Bottom View) dia Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 7.62±0.1 5 0.27 MAX 2.54±0.1 1 5.08 2.54 (No coil polarity) 5.08±0.1 7.62 10.16 4 10.16±0.1 * Average value Precautions Be sure to read the precautions and information common to all Electromechanical Relays, contained in the Technical User’s Guide, “Electromechanical Relays, Technical Information” for correct use. 4 PCB Relay G5Q MEMO PCB Relay G5Q 5 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.components.omron.com 847-882-2288 Cat. No. J155-E-04 6 PCB Relay 11/13 G5Q Specifications subject to change without notice Printed in USA