OMRON G5Q

PCB Relay
G5Q
Compact, High Isolation Relay
• Compact single pole relay with high isolation between
coil and contacts.
• Ensures a withstand impulse voltage of 8,000V between
the coil and contacts.
• Low coil power consumption.
• UL class F coil insulation.
• UL recognized / CSA certified. EN approved.
• Ideal for appliance and HVAC controls
• RoHS Compliant
Ordering Information
To Order: Select the part number and add the desired coil voltage and rating. (e.g., G5Q-14 DC12)
Classification
Single contact, class F coil insulation
SPST-NO
SPDT
Enclosure rating
Model
Flux protection
G5Q-1A
Fully-sealed
G5Q-1A4
Flux protection
G5Q-1
Fully-sealed
G5Q-14
Note: Add “-EU” before the coil voltage to obtain versions with CTI > 250. (e.g., G5Q-1A4-EU DC12)
Specifications for "EU" type differ from standard models. Contact Omron for more details
Specifications
■ Coil Ratings
Rated voltage (V)
SPDT
SPST-NO
Rated coil
current (mA)
Coil resistance
(Ω)
DC 5
80
63
DC 9
44.4
202
DC 12
33.3
360
DC 24
16.7
1440
DC 5
40
125
DC 9
22.2
405
DC 12
16.7
720
DC 24
8.3
2880
Pick-up
voltage
Drop-out
voltage
Maximum
voltage
Power
consumption
(mW)
Percent of rated voltage
75% max
5% min
190% @ 23°C
400
200
Note: 1. Rated current and coil resistance are measured at 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Maximum voltage” is the maximum voltage that can be applied to the relay coil.
PCB Relay
G5Q
1
■ Contact Ratings
Item
Rated load (resistive)
SPDT
10 A at 125 VAC (NO)
3 A at 250 VAC (NO)
3 A at 125 VAC (NO)
5 A at 30 VDC (NO)
3 A at 250 VAC (NC)
3 A at 125 VAC (NC)
3 A at 30 VDC (NC)
Single
Ag alloy (Cd free)
10 A (NO)/3 A (NC)
277 VAC, 30 VDC
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
1250 VA, 150 W (NO)
750 VA, 90 W (NC)
Contact type
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load (120 operations/minute)
SPST-NO
10 A at 125 VAC
3 A at 250 VAC
3 A at 125 VAC
5 A at 30 VDC
10 mA at 5 VDC (P level: λ60 = 0.1 × 10−6/operation)
■ Characteristics
Contact resistance (See note 2.)
Operate time
Release time
Insulation resistance (See note 3.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy (See Note 4)
Mechanical
Electrical
100 mΩ max.
10 ms max.
5 ms max.
1,000 mΩ min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 × 50 μs) between coil and contacts
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
10,000,000 operations (18,000 operations per hour)
NO
50,000 operations: 10 A at 125 VAC resistive load (operations: ON for 1 sec, OFF for 3 sec.)
200,000 operations: 3 A at 125 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.)
100,000 operations: 3 A at 250 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.)
100,000 operations: 5 A at 30 VDC resistive load (operations: ON for 1 sec, OFF for 1 sec.)
NC
200,000 operations: 3 A at 125 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.)
100,000 operations: 3 A at 250 VAC resistive load (operations: ON for 1 sec, OFF for 1 sec.)
100,000 operations: 3 A at 30 VDC resistive load (operations: ON for 1 sec, OFF for 1 sec.)
Ambient temperature
Operating &
storage
−40°C to 105°C with no icing or condensation
Ambient humidity
Operating &
storage
5% to 85%
Weight
Note: 1.
2.
3.
4.
2
Approx. 6.5 g
The data shown above are initial values.
The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.
The electrical life data items shown are possible at 23°C
PCB Relay
G5Q
■ Approved Standard
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp = 40°C
Model
Contact Form
Coil ratings
Number of test
operations
Contact ratings
10 A 250 VAC N.O. only (resistive)
6,000
10 A 30 VDC N.O. only (resistive)
SPST-NO (1a)
SPDT (1c)
G5Q
5 to 48 VDC
4 A 120 VAC N.O. only (resistive)
100,000
3 A 250 VAC N.C. only (resistive)
6,000
3 A 30 VDC N.O. only (resistive)
EC/IEC, VDE (Certified / No.40003467) - - Ambient Temp = 105°C
Model
Contact Form
Coil ratings
Contact ratings
Number of test
operations
G5Q
SPST-NO (1a)
SPDT (1c)
5, 9, 12, 24 VDC
10 A 250 VAC (cosφ=1)(N.O.)
5 A 30 VDC (0 ms)(N.O.)
3 A 30 VDC (0 ms)(N.C.)
10,000
Engineering Data
Switching current (A)
100
AC resistive load (NO)
10
DC resistive load (NO)
AC resistive load (NC)
Maximum coil voltage (% of rated)
Ambient Temperature vs
Maximum Coil Voltage
Maximum Switching Capacity
Shock Malfunction
200
Y
1,000
180
160
X
1,000
140
Z
1,000
120
100
NC
NO Contact
300 Contact
80
300
1,000
Z
60
1,000
X
40
DC resistive load (NC)
20
1,000
Y
1
1
10
100
1000
Switching voltgate (V)
0
-40
-20
0
20 23 40
60
80 85 100 120
Ambient temperature (°C)
Unit: m/s2
Sample: G5Q-14 DC12
Shock direction
Number of Relays: 5 pcs
X
X
Y
Test Conditions: Shock is applied
Z
in ±X, ±Y and ±Z directions three
times each with without
Z
energizing the Relays to check
Y
the number of malfunctions.
Requirements: None malfunction
100 m/s2
PCB Relay
G5Q
3
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G5Q-1A
G5Q-1A4
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3MAX
(10.0)*
20.3MAX
(20.0)*
.
(1.18)
±
1.3
0.1
dia
4-
(1.19)
1
0.27
MAX
(No coil polarity)
10.16±0.1
1
0.4 x 0.4
7.62
10.16
* Average value
7.62
G5Q-1
G5Q-14
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3MAX
(10.0)*
20.3MAX
(20.0)*
(1.18)
.
.3
5-1
.1
±0
(1.19)
15.8MAX
(15.5)*
0.4
3.4
0.4 x 0.4
3
5
7.62±0.1
3.4
2
7.62±0.1
15.8MAX
(15.5)*
0.4
Terminal Arrangement/
Internal Connections
(Bottom View)
dia
Terminal Arrangement/
Internal Connections
(Bottom View)
1
2
3
7.62±0.1
5
0.27
MAX
2.54±0.1
1
5.08
2.54
(No coil polarity)
5.08±0.1
7.62
10.16
4
10.16±0.1
* Average value
Precautions
Be sure to read the precautions and information common to all Electromechanical Relays, contained in the Technical User’s Guide,
“Electromechanical Relays, Technical Information” for correct use.
4
PCB Relay
G5Q
MEMO
PCB Relay
G5Q
5
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.components.omron.com
847-882-2288
Cat. No. J155-E-04
6
PCB Relay
11/13
G5Q
Specifications subject to change without notice