OMRON G5Q-1A4-DC24

G5Q
PCB Power Relay
A Miniature Power Relay with
1-pole 10A Switching Capacity
• Compact single pole relay.
• Excellent switching performance for a variety of loads.
• Small, yet provide 8-kV impulse withstand voltage (between coil
and contacts).
RoHS Compliant
■Model Number Legend
■Application Examples
G 5 Q -@ @ @
———
1 2 3
1. Number of
Poles
1: 1-pole
• Ideal for output applications of control equipments.
2. Contact Form
None : SPDT (1c)
A : SPST-NO (1a)
3. Enclosure rating
None : Flux protection
4 : Fully-sealed
G
5
Q
■Ordering Information
Terminal
Shape
Classification
Enclosure
rating
Contact
form
SPST-NO
(1a)
PCB
terminals
Flux protection
Model
G5Q-1A
Standard
SPDT
(1c)
G5Q-1
Fully-sealed
Rated coil
voltage
5 VDC
9 VDC
12 VDC
24 VDC
5 VDC
9 VDC
12 VDC
24 VDC
Model
G5Q-1A4
G5Q-14
Rated coil
voltage
5 VDC
9 VDC
12 VDC
24 VDC
5 VDC
9 VDC
12 VDC
24 VDC
Minimum
packing unit
40 pcs/
tube
Note. When ordering, add the rated coil voltage to the
model number.
Example: G5Q-1A 5 VDC
Rated coil voltage
■Ratings
●Coil
Contact form
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage
(V)
Must release
voltage
(V)
% of rated voltage
5 VDC
125
40
9 VDC
405
22.2
SPST-NO (1a)
12 VDC
720
16.7
24 VDC
2880
8.3
75% max.
5% min.
5 VDC
63
80
9 VDC
202
44.4
SPDT (1c)
12 VDC
360
33.3
24 VDC
1440
16.7
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Max. voltage
(V)
Power
consumption
(mW)
Approx. 200
190%
(at 23°C)
Approx. 400
●Contacts
Load
Item
SPST-NO (1a)
Contact Type
Single
Contact material
Ag-Alloy (Cd free)
Rated load
(resistive)
Rated carry current
Max. switching
voltage
Max. switching
current
10 A at 125 VAC
3 A at 125 VAC
3 A at 250 VAC
5 A at 30 VDC
Resistive load
SPDT (1c)
10 A at 125 VAC (NO)
3 A at 125 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
10 A (NO)/3 A (NC)
277 VAC, 30 VDC
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
1
G5Q
PCB Power Relay
■Characteristics
Item
Classification
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance *2
Dielectric
strength
1,000 MΩ min.
Between coil
and contacts
4,000 VAC, 50/60 Hz for 1 min
Between
contacts of the
same polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage
(between coil and contacts)
8 kV (1.2 x 50 μs)
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock
resistance
Destruction
1,000 m/s2
Malfunction
100 m/s2
Durability
Mechanical
10,000,000 operations (18,000 operations per hour)
Electrical
• NO
50,000 operations: 10 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec)
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 5 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
• NC
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
Failure rate (P level)
(reference *3)
10 mA at 5 VDC
Ambient operating
temperature
-40°C to 85°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 6.5 g
Note. The data shown above are initial values.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.
*3. This value was measured at a switching frequency of 120 operations/min.
■Engineering Data
●Ambient Temperature VS.
Maximum Coil Voltage
100
AC resistive load (NO)
10
DC resistive load (NO)
AC resistive load (NC)
Maximum coil voltage (% of rated)
●Maximum Switching Capacity
Switching current (A)
G
5
Q
Standard model
Contact resistance *1
●Shock Malfunction
Y
200
1,000
180
160
X
1,000
140
Z
1,000
120
NC
NO Contact
300 Contact
100
80
1,000
Z'
60
300
1,000
X'
40
DC resistive load (NC)
1
1
10
100
1000
Switching voltgate (V)
2
1,000
Y'
20
0
-40
-20
0
20 23 40
60
80 85 100 120
Ambient temperature (°C)
Unit: m/s2
Shock direction
Sample: G5Q-14 12 VDC
X
X'
Number of Relays: 5 pcs
Y
Test conditions: Shock is applied
Z
in ±X, ±Y, and ±Z directions three
Z'
times each with without
energizing the Relays to check Y'
the number of malfunctions.
Requirement: None malfuction
100 m/s2
G5Q
PCB Power Relay
■Dimensions
(Unit: mm)
G5Q-1A
G5Q-1A4
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3MAX
(10.0)*
20.3MAX
(20.0)*
.
.1
(1.18)
3
-1.
±0
dia
Terminal Arrangement/
Internal Connections
(Bottom View)
4
(1.19)
1
2
3
7.62±0.1
15.8MAX
(15.5)*
5
(No coil polarity)
7.62±0.1
0.4
0.27
MAX
3.4
10.16±0.1
1
0.4 x 0.4
7.62
10.16
* Average value
7.62
G5Q-1
G5Q-14
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3MAX
(10.0)*
20.3MAX
(20.0)*
(1.18)
.
.
5-1
0.1
3±
(1.19)
15.8MAX
(15.5)*
d ia
Terminal Arrangement/
Internal Connections
(Bottom View)
1
2
3
7.62±0.1
5
0.4
0.27
MAX
3.4
0.4 x 0.4
2.54±0.1
1
5.08
(No coil polarity)
5.08±0.1
7.62
10.16
4
2.54
10.16±0.1
G
5
Q
* Average value
■Approved Standards
UL Recognized:
CSA Certified:
Model
(File No. E41515)
(File No. LR31928)
Contact form
Coil ratings
Contact ratings
10 A 250 VAC N.O. only (Resistive) 40•C
10 A 30 VDC N.O. only (Resistive) 40•C
G5Q
SPST-NO (1a)
SPDT (1c)
5 to 48 VDC
4 A 120 VAC N.O. only (Resistive) 40•C
3 A 250 VAC N.C. only (Resistive) 40•C
3 A 30 VDC N.C. only (Resistive) 40•C
EC/IEC, VDE
Number of test
operations
6,000
100,000
6,000
(Certified/No.40009467)
Model
Contact form
Coil ratings
G5Q
SPST-NO (1a)
SPDT (1c)
5, 9, 12, 24 VDC
Contact ratings
10 A 250 VAC (cosφ=1) (N.O.) 105•C
5 A 30 VDC (0 ms) (N.O.) 105•C
3 A 30 VDC (0 ms) (N.C.) 105•C
Number of test
operations
10,000
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
3
G5Q
PCB Power Relay
G
5
Q
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. J155-E1-03
0812(0207)(O)
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
G5Q-1A4-DC5 G5Q-1A4-DC12 G5Q-14-DC5 G5Q-1A4-DC24 G5Q-14-DC12 G5Q-14-DC24 G5Q-1-DC5 G5Q1A-DC5 G5Q-1-DC12 G5Q-1-DC24 G5Q-1A-DC12 G5Q-1A-DC24 G5Q-1 DC22 G5Q-14 DC18 G5Q-1A4 DC9