G3TB I/O Solid State Relay I/O SSR Used as Interface between Logic Circuitry and Load • A variety of AC/DC input and output modules are classified by color. • Operation can be monitored easily by LED indicator. • Dielectric strength of 4,000 V between input and output terminals. • Lineup includes models with UL and CSA certification (model numbers ending in “-US”). Refer to "Solid State Relays Common Precautions". RoHS Compliant ■List of Models • Input Modules Isolation Indicator Logic level Supply voltage Logic level Supply current Rated input voltage Model Minimun packing unit Photocoupler Yes 4 to 32 VDC 25 mA 100 to 240 VAC 5 to 24 VDC G3TB-IAZR02P G3TB-IDZR02P 20 pcs Rated input voltage Model Minimun packing unit 5 to 24 VDC 4 to 24 VDC 5 to 24 VDC 4 to 24 VDC 5 to 24 VDC 4 to 24 VDC 5 to 24 VDC 4 to 24 VDC G3TB-OA203PZ G3TB-OA203PZM G3TB-OA203PL G3TB-OA203PLM G3TB-ODX03P G3TB-ODX03PM G3TB-OD201P G3TB-OD201PM 20 pcs • Output Modules Isolation Zero cross function Yes No Photocoupler − Indicator Rated output voltage Yes No Yes No Yes No Yes No 3 A at 100 to 240 VAC 3 A at 5 to 48 VDC 1.5 A at 48 to 200 VDC G 3 T B ■Ratings • Input Module Input Output Item Model G3TB-IAZR02P G3TB-IDZR02P Rated voltage Operating voltage Input current 100 to 240 VAC 5 to 24 VDC 80 to 264 VAC 4 to 32 VDC 5 mA max. 5 mA max. Voltage level Must operate Must release voltage voltage 80 VAC max. 10 VAC min. 4 VDC max. 1 VDC min. Item Model G3TB-IAZR02P Output Output Logic level breakdown current supply voltage voltage 4 to 32 VDC G3TB-IDZR02P 4 to 32 VDC 32 VDC max. 25 mA max. • Output Module Input Item Model G3TB-OA203PZ G3TB-OA203PZM G3TB-OA203PL G3TB-OA203PLM G3TB-ODX03P G3TB-ODX03PM G3TB-OD201P G3TB-OD201PM Rated voltage Operating voltage Input current 5 to 24 VDC 4 to 24 VDC 5 to 24 VDC 4 to 24 VDC 5 to 24 VDC 4 to 24 VDC 5 to 24 VDC 4 to 24 VDC 4 to 32 VDC 3 to 32 VDC 4 to 32 VDC 3 to 32 VDC 4 to 32 VDC 3 to 32 VDC 4 to 32 VDC 3 to 32 VDC 5 mA max. Voltage level Must operate Must release voltage voltage 4 VDC max. 3 VDC max. 4 VDC max. 3 VDC max. 1 VDC min. 4 VDC max. 3 VDC max. 4 VDC max. 3 VDC max. Output Item Model G3TB-OA203PZ G3TB-OA203PZM G3TB-OA203PL G3TB-OA203PLM G3TB-ODX03P G3TB-ODX03PM G3TB-OD201P G3TB-OD201PM Applicable load Rated load voltage Load voltage range Load current 100 to 240 VAC 75 to 264 VAC 0.05 to 3 A *1, 2 Inrush current 45 A (60 Hz, 1 cycle) 5 to 48 VDC 4 to 60 VDC 0.01 to 3 A *1, 2 18 A (10 ms) 48 to 200 VDC 40 to 200 VDC 0.01 to 1.5 A *1, 2 9 A (10 ms) *1. *2. The minimum current value is measured at 10°C min. The applicable output load current varies depending on the ambient temperature.Refer to reference data the "Load Current vs. Ambient Temperature" rating characteristic for details. 1 G3TB I/O Solid State Relay ■Characteristics • Input Module Model • Output Module G3TB-IAZR02P G3TB-IDZR02P Operate time 20 ms max. 1 ms max. Release time 20 ms max. 1 ms max. Item Output ON voltage drop 0.4 V max. 100 μA max. Leakage current 100 MΩ min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between input and output Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5mm double amplitude) 1,000 m/s2 Shock resistance Ambient operating temperature Model G3TBOA203PZ G3TBG3TBOA203PZM OA203PL G3TBOA203PLM G3TB ODX03P Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current Insulation resistance Storage temperature Item G3TBODX03PM 1 ms max. G3TB OD201P G3TBOD201PM 0.5 ms max. 2 ms max. 1.6 V max. 5 mA max. (at 200 VAC) 2.5 V max. 1 mA max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between input and output Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5mm double amplitude) 1,000 m/s2 Shock resistance –30°C to 100°C (with no icing or condensation) Storage temperature –30°C to 100°C (with no icing or condensation) –30°C to 80°C (with no icing or condensation) Ambient operating temperature –30°C to 80°C (with no icing or condensation) Minimum load current: 10 to 80°C Refer to the Load Current - Ambient Temperature Rating for the minimum load current. Ambient operating humidity Ambient operating humidity 45% to 85%RH Weight Approx. 22 g 45% to 85%RH Weight Approx. 32 g ■Engineering Data 4 4 3 3 2 2 1 0.1 0.05 0 -30 G3TB-OD201P G3TB-OD201PM Load current (A) Load current (A) Load current (A) • Load Current vs. Ambient Temperature Characteristics G3TB-OA203PZ G3TB-OA203PLM G3TB-ODX03P G G3TB-OA203PZM 3 G3TB-OA203PL G3TB-ODX03PM T 5 5 B 1.5 1 0.5 1 Minimum load current -20 0 10 20 40 60 80 100 2 0.1 Minimum load current 0.01 0 -30 -20 0 10 20 Ambient temperature (°C) 40 60 80 100 0.1 Minimum load current 0.01 0 -30 -20 0 10 20 40 60 80 100 Ambient temperature (°C) Ambient temperature (°C) 50 40 30 20 10 0 10 30 50 100 200 500 1,000 5,000 Energized time (ms) 2 Inrush current (A. Peak) Inrush current (A. Peak) Inrush current (A. Peak) • One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3TB-OA203PZ G3TB-OA203PL G3TB-ODX03P G3TB-OD201P G3TB-OA203PZM G3TB-OA203PLM G3TB-ODX03PM G3TB-OD201PM 30 28 26 24 22 20 18 15 14 13 12 11 10 9 16 8 14 7 12 6 10 5 8 4 6 3 4 2 2 0 10 1 0 10 30 50 100 300 500 1,000 3,000 Energized time (ms) 30 50 100 300 500 1,000 3,000 Energized time (ms) G3TB I/O Solid State Relay ■Circuit Configuration Circuit White Yes Yes Black AC output G3TB-OA203PZM G3TB-OA203PLM No G3TB-ODX03P G3TB-OD201P Yes DC output Red G3TB-ODX03PM G3TB-OD201PM No • Example of Logic Output Circuit Example 1. G3TB-I Example 2. G3TB-I 4 to 32 VDC 3.3K 4 (−) +3 SW (+) Sequential circuit or CPU SW (+) +3 −5 3.3K 4 (−) −5 G 3 T B Load G3TB-OA203PZ G3TB-OA203PL Amplification circuit G3TB-IDZR02P Zero-cross circuit DC input Amplification circuit Yes Constant-current circuit Yellow Constant-current circuit G3TB-IAZR02P Constant-current Rectification circuit circuit AC input Amplification circuit Indicator Drive circuit Case color Constant-current circuit Model Rectification circuit Type Example: Relay with built-in inrush absorption diode 4 to 32 VDC Note: AC- and DC-input versions are available. Logic circuitry Note: AC- and DC-input versions are available. ■Dimensions (Unit: mm) Input SSR G3TB-I PCB Dimensions (Bottom View) 2.54 Five, 1.3-dia. holes 2.54 10 max. 6.05 20.5 max. 23.2 10.16 12.7 5.08 5.08 Terminal Arrangement (Bottom View) 0.6 1 + External input Output 2 − 3 + 4 5 − Vcc 1 ~ Output 2 ~ 3 + 4 5 − Vcc Logic circuit 6.6 Load 33.02±0.1 43.5 max. 0.8 Load 10.16±0.1 22.86±0.1 27.94±0.1 External input Logic circuit 6.05±0.1 3 G3TB I/O Solid State Relay Output SSR G3TB-I PCB Dimensions (Bottom View) 2.54 Four, 1.2-dia. holes 2.54 10 max. 6.05 5.08 12.7 Terminal Arrangement (Bottom View) 29.5 30.5 max. 33.2 External AC output 1 ~ 0.8 43.5 max. 6.6 Logic input 3 + External DC output 4 − 1 + 2 − Logic input 3 + 4 − Z2 0.6 Z1 Load 10.16±0.1 22.86±0.1 27.94±0.1 2 ~ Load 6.05±0.1 10.16 Note. Connect the varistor to the Z1 or Z2. Note. Connect the diode in parallel with the load. ■Safety Precautions ●Please refer to “Solid State Relays Common Precautions” for correct use. Precautions for Correct Use • SSR for I/O classification by the color is as follows: G 3 T B AC equipment 100 to 240 VAC DC equipment 5 to 24 VDC AC equipment 100 to 240 VAC 3 A Yellow G3TB-IAZR02P AC input module White G3TB-IDZR02P DC input module G3TB-OA203PZ G3TB-OA203PZM G3TB-OA203PL G3TB-OA203PLM Black 5 to 24 VDC 5 to 24 VDC 5 to 24 VDC (4 to 24 VDC) AC output module DC equipment 4 to 60 VDC/40 to 200 VDC 3 A * With 1.5-A output. G3TB-ODX03P G3TB-ODX03PM * G3TB-OD201P * G3TB-OD201PM Red DC output module • When mounting more than one output module, make a distance of 5 mm minimum between adjacent SSRs. Up to 16-point, 3-A load switching is possible. 4 Output module 5 mm min. 5 to 24 VDC (4 to 24 VDC) PLC or logic circuitry G3TB I/O Solid State Relay G 3 T B • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K077-E1-05 1014(0207)(O) 5