Datasheet

G6D
PCB Power Relay
Slim, Miniature Relay, Capable
of Relaying Programmable
Controller and Temperature
Controller Outputs
• Reduced board space, ideal for high-density mounting (45%.
(6.5 mm (W) × 17.5 mm (L) × 12.5 mm (H))
• Small, yet switches 5 A at 250 VAC/30 VDC.
• Allows 300,000 operations with a 2A load at 250 VAC or
30 VDC.
RoHS Compliant
■Model Number Legend
■Application Examples
G6D- @ @- @- @
—— — —
• Ideal for output applications of control
equipments.
1 2 3 4
1. Number of Poles
1: 1-pole
3. Contact Material
ASI: Silver alloy
(cadmium-free)
2. Contact Form
A: SPST-NO (1a)
■Characteristics
4. Contact surface
AP: Au plated
■Ordering Information
Enclosure rating
Contact form
Terminal shape
Model
Rated coil voltage
Minimun packing
unit
5 VDC
12 VDC
24 VDC
12 VDC
24 VDC
25 pcs/tube
G6D-1A-ASI
Fully sealed
SPST-NO (1a)
PCB terminals
G6D-1A-ASI-AP
Note. When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked
as @@ VDC.
●Connecting Socket
Applicable relay
G6D-1A-ASI
Model
P6D-04P
Minimun packing unit
25 pcs
■Ratings
●Coil
Item
Rated voltage
5 VDC
12 VDC
24 VDC
Rated
current
(mA)
Coil
resistance
(Ω)
40
16.7
8.3
125
720
2,880
Must operate Must release
Max.
voltage
voltage
voltage
(V)
(V)
(V)
% of rated voltage
70% max.*
10% min.
160%
(at 23 C)
Power
consumption
(mW)
Approx. 200
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
●Contacts
Item
Contact Type
Load
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
G
6
D
Resistive load
Single
Ag-Alloy (Cd free)
(Ag-alloy (Cd free) and Au plated)*
5 A at 250 VAC
5 A at 30 VDC
5A
250 VAC, 30 VDC
5A
* The content indicated in
parentheses ( ) are for
the G6D-1A-ASI-AP
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between coil
and contacts
Dielectric Between
strength
contacts of
the same
polarity
Impulse withstand voltage
(between coil and contacts)
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min.
3,000 VAC, 50/60 Hz for
1 min
750 VAC, 50/60 Hz for
1 min
6 kV (1.2 x 50 μs)
10 to 55 to 10 Hz, 0.75 mm
single amplitude (1.5 mm
double amplitude)
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm
Malfunction
single amplitude
(1.5 mm double amplitude)
Destruction
1,000 m/s2
Shock
resistance Malfunction
100 m/s2
20,000,000 operations min.
Mechanical
(at 18,000 operations/hr)
70,000 operations min.
(5 A at 250 VAC, resistive
load)
70,000 operations min.
(5 A at 30 VDC, resistive
Durability
load)
Electrical
300,000 operations min.
(2 A at 250 VAC, resistive
load)
300,000 operations min.
(2 A at 30 VDC, resistive
load)
(at 1,800 operations/hr)
Failure rate (P level)
10 mA at 5 VDC
(reference value *3)
(1 mA at 5 VDC) *4
Ambient operating
-25 C to 70 C (with no icing
temperature
or condensation)
Ambient operating humidity 5% to 85%
Weight
Approx. 3 g
Destruction
Note. The data given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Measurement conditions: The insulation
resistance was measured with a 500 VDC
megohmmeter at the same locations as the
dielectric strength was measured.
*3. This value was measured at a switching
frequency of 120 operations/min.
*4. The values indicated in parentheses ( ) are
for the G6D-1A-ASI-AP.
1
G6D
PCB Power Relay
■Engineering Data
●Durability
30
10
AC resistive load
5
3
●Ambient Temperature vs.
Maximum Coil Voltage
500
Maximum coil voltage (%)
50
Durability (x104 operations)
Switching current (A)
●Maximum Switching Capacity
300
100
250 VAC/30 VDC resistive load
50
30
200
180
160
140
DC resistive load
1
120
AC inductive
load
cosφ=0.4
DC inductive load
0.5
10
100
5 250 VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
3
0.3
80
0.1
0
3
5
10
30
100
0
250 500 1,000
1
2
3
4
5
6
7
8
9
60
10
0
23
30
40
50
Switching current (A)
Switching voltage (V)
60
70
80
90
Ambient temperature (°C)
Note. The maximum coil voltage is the maximum
voltage that can be applied to the relay coil.
G
6
D
Must operate and must release voltage (ratio of rated voltage) (%)
●Ambient Temperature vs. Must
Operate and Must Release
Voltages
G6D-1A-ASI (-AP)
100
●Shock Malfunction
G6D-1A-ASI (-AP)
Y
Sample: G6D-1A-ASI
Number of Relays:
5 pcs
Must Operating voltage
Must Recovery voltage
80
600
X
Z
400
max.
200
X
60
1,000
800
min.
206
40
Z'
max.
X
min.
20
X'
Shock direction
X
X'
De-energized
Y
0
-40
Z
Z'
Unit: m/s2
Energized Y'
Y'
-20
0
20
40
60
80
Coil terminals
Sample: G6D-1A-ASI 24 VDC
Number of Relays: 5 pcs
Test conditions: Impose a shock in the ±X, ±Y, and ±Z
directions three times each with the Relay energized to
check the shock values that cause the Relay to
malfunction.
Ambient temperature (°C)
■Dimensions
PCB Mounting Holes
(Bottom View)
G6D-1A-ASI (-AP)
0.5
Terminal Arrangement/
Internal Connections
(Bottom View)
6.5 max.
(6.4)*
17.5 max.
(17.3)*
2.54
Four, 1.1-dia.
(0.71)
12.5 max.
(12.4)*
5.08
3.5
0.5
2.54
0.8
7.62
5.08
(1.13)
(No coil polarity)
5.08
10.16
Note: Orientation marks are indicated as follows:
* Average value
Socket
P6D-04P
13
0.3
5.08
5
1
2.54
PCB Mounting Holes
(Bottom View)
19.7 max.
(19.5)*
6.9 max.
(6.7)*
2.54
Four, 1.1-dia.
(0.86)
10.8
6±0.1
2.54
5.08
3.6
0.3
0.65
2.54
7.62
5.08
* Average value
2
(2.18)
10.16
5.08
7
G6D
PCB Power Relay
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this datasheet.
UL Recognized
(File No. E41515)
Model
Number of
poles
Coil ratings
G6D-1A-ASI (-AP)
1
5 to 24 VDC
CSA Certified
Contact ratings
Number of test
operations
5 A, 250 VAC 40°C
5 A, 30 VDC 40°C
6,000
(File No. LR31928)
Model
Number of
poles
Coil ratings
G6D-1A-ASI (-AP)
1
5 to 24 VDC
EN/TÜV Certified
Contact ratings
Number of test
operations
5 A, 250 VAC (Resistive) 40°C
5 A, 30 VDC (Resistive) 40°C
6,000
(Registration No. R50167084)
Model
Number of
poles
Coil ratings
G6D-1A-ASI (-AP)
1
5, 12, 24 VDC
Contact ratings
Number of test
operations
5 A, 250 VAC (cosφ=1.0) 70°C
5 A, 30 VDC (0 ms) 40°C
70,000
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
• More than two relays can be closely
mounted right side up as shown in the
following illustration.
Upper side
6.5 mm
Current flow: 5 A max.
G
6
D
●Socket Mounting Height
18.5 mm max.
Upper side
1.12 mm 7.62 mm in the
upside-down direction
Current flow: 2 A max.
Note. The space between each relay required for
heat radiation may vary with operating
conditions. Contact your OMRON
representative for details.
●Mounting to a P6D
• The P6D is flux-resistive. Do not wash
the P6D with water.
• Dismount the relay from the socket
before soldering the socket to a PCB.
• Use Surge Killer Diode when switching
a DC inductive load in micro load
(about 10 to 100 mA).
(Carbon deposition may decrease the
contact reliability.)
3
G6D
PCB Power Relay
G
6
D
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. K127-E1-04
0316(0207)(O)