G3DZ Solid State Relays SSR Identical to the G6D in Size with AC/DC dual-use type and DC-only Type Available for the Whole Product Line • 10-μA current leakage max. between open output terminals. • 2,500-VAC dielectric strength ensured between input and output terminals. • With or without input resistor incorporated models available. • Incorporated with overvoltage absorption circuit (models with AC/DC output only). • Full-wave rectified and half-wave rectified AC current switchable (excluding G3DZ-DZ02P(G)). • Standard models are available with UL and CSA certification. RoHS Compliant Refer to "Solid State Relays Common Precautions". ■Model Number Legend G 3 D Z -@ @ @@ @ @ — ——— — — — 1 2 G 3 D Z 3 4 5 2. Rated Load Current R5 : 0.5 A R6 : 0.6 A 02 : 2 A 1. Rated Load Power Supply Voltage 1 : 125 VAC 2 : 240 VAC DZ : 24 VDC 3. Terminal Type P: PCB terminals 4. Zero Cross Function (For AC/DC dual-use type only) L: Not equipped with zero cross function 5. Input Resistance None: With input resistance G : Without input resistance ■List of Models • With Input Resistance Isolation Zero cross function Indicator Rated output load 0.6 A 5 to 240 VAC 5 to 100 VDC Photo-voltage coupler No No 0.5 A 5 to 100 VAC 5 to 100 VDC Rated input voltage Model Minimum packing unit 5 VDC 12 VDC G3DZ-2R6PL 24 VDC 5 VDC 12 VDC G3DZ-1R5PL 25 pcs 24 VDC 5 VDC 2.0 A 5 to 24 VDC 12 VDC G3DZ-DZ02P 24 VDC • Without Input Resistance Isolation Zero cross function Photo-voltage coupler No Indicator Rated output load Max. input current No 0.5 A 3 to 125 VAC 3 to 125 VDC 50 mA (DC input) 2.0 A 3 to 26.4 VDC Model Minimum packing unit G3DZ-1R5PLG 25 pcs G3DZ-DZ02PG • Connecting Socket Applicable Relay Model G3DZ-@ P6D-04P 1 G3DZ Solid State Relays ■Ratings • With Input Resistance Item Input Rated Operating voltage voltage Model 5 VDC G3DZ-2R6PL 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 4 kΩ ±20% 19.2 VDC max. 750 Ω ±20% 4 to 6 VDC 12 VDC 9.6 to 14.4 VDC 24 VDC 19.2 to 28.8 VDC Load voltage range 5 to 240 VAC 5 to 100 VDC 3 to 264 VAC 3 to 125 VDC AC: 100 μ to 0.6 A 6 A (10 ms) DC: 10 μ to 0.6 A 5 to 100 VAC 5 to 100 VDC 3 to 125 VAC 3 to 125 VDC AC: 100 μ to 0.5 A 5 A (10 ms) DC: 10 μ to 0.5 A 5 to 24 VDC 3 to 26.4 VDC DC: 10 μ to 2.0 A Load current * Inrush current 4 VDC max. 2 kΩ ±20% 9.6 VDC max. 4 kΩ ±20% 19.2 VDC max. 750 Ω ±20% 4 to 6 VDC Rated load voltage Must release voltage 4 VDC max. 2 kΩ ±20% 5 VDC G3DZ-DZ02P Must operate voltage 12 VDC 9.6 to 14.4 VDC 5 VDC G3DZ-1R5PL Impedance 830 Ω ±20% 4 to 6 VDC Output Voltage level 1 VDC min. 4 VDC max. 12 VDC 9.6 to 14.4 VDC 2 kΩ ±20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 4 kΩ ±20% 19.2 VDC max. 20 A (10 ms) * The applicable output load current varies depending on the ambient temperature. Refer to reference data the "Load Current vs. Ambient Temperature" rating characteristic for details. • Without Input Resistance Item Symbol Max. input current Rated current Input G 3 D Z Output G3DZ-1R5PLG G3DZ-DZ02PG 50 mA max. IIN 6.25 mA (recommendation value) Must operate current IOP 4 mA max. Must release current IRE 0.6 mA max. Input release voltage VR 3V Foward voltage VF 1.4 V (TYP) Load voltage range 3 to 125 VAC 3 to 125 VDC 3 to 26.4 VDC Load current 100 μ to 0.5 A 100 μ to 2.0 A Inrush current 5 A (10 ms) 20 A (10 ms) ■Characteristics (at 25°C) Item Model G3DZ-2R6PL G3DZ-1R5PL G3DZ-1R5PLG Operate time * Release time * Output ON-resistance * Leakage current at OFF state G3DZ-DZ02P 10 ms max. 2.4 Ω max. 3.0 Ω max. 0.15 Ω max. 10 μA max. (at 125 VDC) 100 μA max. (at 200 VAC) 10 μA max. (at 125 VDC) 50 μA max. (at 100 VAC) 10 μA max. (at 26.4 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between input and output Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 1,000 m/s2 Shock resistance Storage temperature −30°C to 100°C (with no icing or condensation) Ambient operating temperature −30°C to 85°C (with no icing or condensation) Ambient operating humidity Weight G3DZ-DZ02PG 6 ms max. 45% to 85%RH Approx. 3.1 g Approx. 2.8 g Approx. 2.4 g Approx. 2.6 g Approx. 2.4 g * Measurement conditions:For G3DZ-2R6PL/-1R5PL/-DZ02P, the values are under the measurement conditions whereby rated voltages are applied to the input For G3DZ-1R5PLG/-DZ02PG, the values are measured with 6.25 mA current applied to the input. 2 G3DZ Solid State Relays ■Engineering Data Note: The following data is for ambient temperature at 25°C. 0.8 G3DZ-DZ02P(G) 1 Load current (A) 1 Load current (A) Load current (A) • Load Current vs. Ambient Temperature Characteristics G3DZ-2R6PL G3DZ-1R5PL(G) 0.8 3 2.5 2 0.6 0.6 0.4 0.4 1.5 1 0.2 0.2 0 −30 −20 0 20 40 60 0.5 0 −30 −20 80 85 100 0 20 Ambient temperature (°C) 40 60 0 −30 −20 80 85 100 0 20 Ambient temperature (°C) 40 60 80 85 100 Ambient temperature (°C) 8 6 10 Inrush current (A) 10 Inrush current (A. Peak) Inrush current (A. Peak) • Inrush Current Resistivity Non-repetiijve (Keep the inrush current to half the rated value if it occurs repetiijvely.) G3DZ-2R6PL G3DZ-1R5PL(G) G3DZ-DZ02P(G) 8 30 25 20 6 15 4 4 10 2 2 0 5 10 30 50 100 0 300 500 1,000 3,000 5,000 Energized time (ms) G 3 D Z 5 1 3 5 10 30 50 100 300 500 Energized time (ms) 0 1 3 5 10 30 50 100 300 500 Energized time (ms) 250 Operate time (µs)TYP. Operate time (µs)TYP. • Input Current vs. Operate Time Characteristics G3DZ-1R5PLG G3DZ-DZ02PG 200 150 100 80 30 100 40 50 20 0 0 10 20 30 40 0 0 50 10 20 30 Input current (mA) 40 50 Input current (mA) 3.20 Operate time (µs)TYP. Operate time (µs)TYP. • Input Current vs. Release Time Characteristics G3DZ-1R5PLG G3DZ-DZ02PG 3.15 1.2 1.15 3.10 1.1 3.05 1.05 3.00 0 10 20 30 40 50 Input current (mA) 1.0 0 10 20 30 40 50 Input current (mA) 3 G3DZ Solid State Relays ■Dimensions (Unit: mm) G3DZ-2R6PL G3DZ-1R5PL(G) G3DZ-DZ02P(G) Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 0.5 17.5 Four, 1.1 dia. holes 6.5 (1.13) Terminal Arrangement/ Internal Connections (BOTTOM VIEW) G3DZ-2R6PL/-1R5PL(G) 2.54 LOAD (0.71) − 5.08 Input voltage 12.5 max. 2.54 + 3.5 0.5 2.54 0.8 7.62 5.08 5 7 LOAD G3DZ-DZ02P(G) 15.24 0.3 1 − INPUT + 13 5.08 LOAD − The above diagram is a G3DZ-2R6PL Relay. Input voltage Note: Orientation marks are indicated as follows: The load can be connected to either the positive or negative side. ■Socket Load power supply + Load power supply −5 1 7 + − LOAD INPUT + 13 Use the socket P6D-04P. P6D-04P Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 19.7 max. 6.9 max. Socket Mounting Hight Four 1.1-dia. (2.18) 2.54 holes (0.86) 10.8 6±0.1 G 3 D Z 18.5 mm max. 5.08 2.54 3.6 0.65 2.54 15.24 0.3 7.62 5.08 ■Safety Precautions • Please refer to “Solid State Relays Common Precautions” for correct use. Precautions for Correct Use • Reversed Surge Voltage x If any reversed surge voltage is imposed on the input terminals, insert a diode in parallel to the input terminals. Do not impose a reversed voltage value of 3 V or more. • Representative Example of Relay Driver Circuit (For C-MOS) C-MOS +VCC R1 13 5 LOAD VF 1 7 1 − INPUT + 13 5 7 VIN VOL/OH LOAD • Terminals x Since terminals are made of materials with high heat conduction, complete soldering (automatic or manual) with 10 seconds at a temperature of 260°C. When fitting with a Socket, match properly and push straight down vertically. (For transistors) +VCC R1 10~100 kΩ 13 5 LOAD VF 1 7 VIN VOL/OH • Calculation of Input Resistance R1 = 4 VCC−VOL−VF (ON) 4~50 mA • SSR Mounting x Do not wash or solder the PCB while the SSR is mounted in the Socket. G3DZ Solid State Relays G 3 D Z • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K089-E1-07 0616(0207)(O) 5