data sheet - family

Photoelectric sensors
FLDM 170 (Laser, Scatec-15)
Copy counters
sample drawing
30
70
64
17
158
M16 x 0,75
Display and
keypad
61
Interface
connector
°
59
35 23,5
6
M6
ø 6,4
170
13
Main
connector
Laser
beam
12
general data
sample picture
measuring distance Sd
0 ... 120 mm
optimum operating distance
100 mm
counting rate
< 3000000 copies/h
object speed
5 m/sec
object cycle distance
> 1 mm
sensitivity
single sheet/edge thickness 0,15 mm
sync. input
yes
measuring point
visible red laser line 8 mm
light source
pulsed red laser diode
wave length
670 nm
laser class
2
edge indicator
LED yellow
power on indication
LED green
false pulse suppression
4 program options
direct gap detection
yes
sensitivity adjustment
4 preset levels or level set by customer
laser warning
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 620...680nm
Max. av. Output: < 1mW
IEC 60825-1, Ed. 2, 2007
electrical data
voltage supply range +Vs
10 ... 30 VDC
current consumption max. (no load)
230 mA
output pulse length
0,3 ... 100 ms selectable
short circuit protection
yes
reverse polarity protection
yes
interface
serial for ScaDiag software
CLASS 2 LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007
mechanical data
width / diameter
30 mm
type
rectangular
housing material
die-cast zinc
connector base (main connector)
DIN 45322, 6 pin
connector base (interface)
DIN 45326, 8 pin
front (optics)
glass
ambient conditions
operating temperature
0 ... +50 °C
protection class
IP 54
1
www.baumer.com
11/11/2015
Photoelectric sensors
FLDM 170 (Laser, Scatec-15)
Copy counters
order reference
output circuit
FLDM 170C1030/S42
opto isolated
FLDM 170G1030/S42
push-pull
2
www.baumer.com
11/11/2015