EN

Photoelectric sensors
FLDM 170C1011/S42
Copy counters
dimension drawing
70
64
30
17
158
M16 x 0,75
Display and
keypad
47°
Laser
beam
Interface
connector
Main
connector
68
35 23,5
6
M6
ø 6,4
170
13
12
general data
photo
measuring distance Sd
0 ... 90 mm
optimum operating distance
70 mm
counting rate
< 3000000 copies/h
object speed
5 m/sec
object cycle distance
> 1 mm
sensitivity
single sheet/edge thickness 0,1 mm
sync. input
yes
measuring point
visible red laser line 6 mm
light source
pulsed red laser diode
wave length
670 nm
laser class
2
edge indicator
LED yellow
power on indication
LED green
false pulse suppression
4 program options
direct gap detection
yes
sensitivity adjustment
4 preset levels or level set by customer
connection diagram
(3)
(1)
electrical data
200mA 10 Ω
polyfuse
voltage supply range +Vs
10 ... 30 VDC
current consumption max. (no load)
230 mA
(2)
output circuit
opto isolated
(6)
output pulse length
0,3 ... 100 ms selectable
short circuit protection
yes
reverse polarity protection
yes
interface
serial for ScaDiag software
+VS
output
output
ground
laser warning
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 620...680nm
Max. av. Output: < 1mW
IEC 60825-1, Ed. 2, 2007
CLASS 2 LASER PRODUCT
mechanical data
width / diameter
30 mm
type
rectangular
housing material
die-cast zinc
connector base (main connector)
DIN 45322, 6 pin
connector base (interface)
DIN 45326, 8 pin
front (optics)
glass
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007
A software package called ScaDiag allows
to control all functions and settings.
ambient conditions
operating temperature
0 ... +50 °C
protection class
IP 54
FLDM 170C1011/S42
Also the software allows to record
and display measurement sequences
speeding up troubleshooting.
www.baumer.com