MSE1PB, MSE1PD, MSE1PG, MSE1PJ www.vishay.com Vishay General Semiconductor Surface Mount ESD Capability Rectifier FEATURES • • • • ® eSMP Series • • Top View Bottom View • • MicroSMP Very low profile - typical height of 0.65 mm Available Ideal for automated placement Oxide planar chip junction Low forward voltage drop, low leakage current ESD capability Meets MSL level 1, per J-STD-020, LF maximum peak of 260 °C AEC-Q101 qualified Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 TYPICAL APPLICATIONS General purpose, polarity protection, and rail-to-rail protection in both consumer and automotive applications. PRIMARY CHARACTERISTICS IF(AV) 1.0 A VRRM 100 V, 200 V, 400 V, 600 V IFSM 20 A VF at IF = 1.0 A 0.925 V IR 1 μA TJ max. 175 °C Package MicroSMP Diode variations Single die MECHANICAL DATA Case: MicroSMP Molding compound meets UL 94 V-0 flammability rating Base P/N-M3 - halogen-free, RoHS-compliant, and commercial grade Base P/NHM3 - halogen-free, RoHS-compliant, and automotive grade Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD 22-B102 M3 suffix meets JESD 201 class 1A whisker test, HM3 suffix meets JESD 201 class 2 whisker test Polarity: Color band denotes the cathode end MAXIMUM RATINGS (TA = 25 °C, unless otherwise noted) PARAMETER SYMBOL Device marking code MSE1PB MSE1PD MSE1PG MSE1PJ SB SD SG SJ 100 200 400 600 UNIT Max. repetitive peak reverse voltage VRRM Max. average forward rectified current (fig. 1) IF(AV) 1.0 A Peak forward surge current 10 ms single half sine-wave superimposed on rated load IFSM 20 A TJ, TSTG -55 to +175 °C Operating junction and storage temperature range V ELECTRICAL CHARACTERISTICS (TA = 25 °C, unless otherwise noted) PARAMETER TEST CONDITIONS IF = 0.5 A Max. instantaneous forward voltage IF = 1.0 A IF = 0.5 A IF = 1.0 A Max. reverse current Rated VR SYMBOL TA = 25 °C VF (1) TA = 125 °C TA = 25 °C TA = 125 °C IR (2) TYP. MAX. 0.940 - 1.016 1.1 0.834 - 0.925 0.98 - 1.0 3.7 50 UNIT V μA Typical reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 780 - ns Typical junction capacitance 4.0 V, 1 MHz CJ 5 - pF Notes (1) Pulse test: 300 μs pulse width, 1 % duty cycle (2) Pulse test: Pulse width 40 ms Revision: 19-Feb-16 Document Number: 89067 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 MSE1PB, MSE1PD, MSE1PG, MSE1PJ www.vishay.com Vishay General Semiconductor THERMAL CHARACTERISTICS (TA = 25 °C, unless otherwise noted) PARAMETER SYMBOL Typical thermal resistance MSE1PB MSE1PD MSE1PG RJA (1) 110 RJL (1) 30 RJC (1) 40 MSE1PJ UNIT °C/W Note (1) Thermal resistance from junction to ambient and junction to lead mounted on PCB with 6.0 mm x 6.0 mm copper pad areas. R JL is measured at the terminal of cathode band. IMMUNITY TO ELECTRICAL STATIC DISCHARGE TO THE FOLLOWING STANDARDS (TA = 25 °C, unless otherwise noted) STANDARD TEST TYPE TEST CONDITIONS SYMBOL CLASS VALUE AEC-Q101-001 Human body model (contact mode) C = 100 pF, R = 1.5 k H3B > 8 kV AEC-Q101-002 Machine model (contact mode) C = 200 pF, R = 0 M4 > 400 V JESD22-A114 Human body model (contact mode) C = 100 pF, R = 1.5 k 3B > 8 kV JESD22-A115 Machine model (contact mode) C = 200 pF, R = 0 C > 400 V Human body model (contact mode) C = 150 pF, R = 330 4 > 8 kV Human body model (air-discharge mode) (1) C = 150 pF, R = 330 4 > 15 kV IEC 61000-4-2 (2) VC Notes (1) Immunity to IEC 61000-4-2 air discharge mode has a typical performance > 30 kV (2) System ESD standard ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE MSE1PJ-M3/89A 0.006 89A 4500 7" diameter plastic tape and reel MSE1PJHM3/89A (1) 0.006 89A 4500 7" diameter plastic tape and reel Note (1) AEC-Q101 qualified 1.2 1.2 1.0 1.0 D = 0.8 Average Power Loss (W) Average Forward Rectified Current (A) RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 0.8 0.6 0.4 TL Measured at the Cathode Band Terminal 0.2 D = 0.5 0.8 D = 0.3 D = 1.0 D = 0.2 0.6 D = 0.1 T 0.4 0.2 0 D = tp/T tp 0.8 1.0 0 95 105 115 125 135 145 155 165 175 0 0.2 0.4 0.6 1.2 Lead Temperature (°C) Average Forward Current (A) Fig. 1 - Forward Current Derating Curve Fig. 2 - Forward Power Loss Characteristics Revision: 19-Feb-16 Document Number: 89067 2 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 MSE1PB, MSE1PD, MSE1PG, MSE1PJ www.vishay.com Vishay General Semiconductor 10 Junction Capacitance (pF) Instantaneous Forward Current (A) 10 TJ = 175 °C 1 TJ = 25 °C TJ = 50 °C TJ = 150 °C TJ = 75 °C 0.1 TJ = 100 °C TJ = 125 °C 1 0.01 0 0.4 0.8 1.2 1.6 2.0 2.4 0.1 10 100 Reverse Voltage (V) Fig. 3 - Typical Instantaneous Forward Characteristics Fig. 5 - Typical Junction Capacitance 1000 Transient Thermal Impedance (°C/W) 100 Instantaneous Reverse Current (μA) 1 Instantaneous Forward Voltage (V) TJ = 175 °C TJ = 150 °C 10 TJ = 125 °C TJ = 100 °C 1 TJ = 75 °C 0.1 TJ = 25 °C 0.01 20 30 40 50 60 70 80 90 100 10 1 0.01 0.001 10 Junction to Ambient 100 0.1 1 10 100 1000 Percent of Rated Peak Reverse Voltage (%) t - Pulse Duration (s) Fig. 4 - Typical Reverse Leakage Characteristics Fig. 6 - Typical Transient Thermal Impedance PACKAGE OUTLINE DIMENSIONS in inches (millimeters) MicroSMP 0.059 (1.50) 0.043 (1.10) Cathode Band 0.055 (1.40) 0.047 (1.20) 0.030 (0.75) 0.022 (0.55) 0.039 (0.98) 0.031 (0.78) 0.091 (2.30) 0.083 (2.10) 0.106 (2.70) 0.091 (2.30) 0.030 (0.75) 0.022 (0.55) Mounting Pad Layout 0.079 (2.00) 0.029 (0.73) 0.025 (0.63) 0.043 (1.10) 0.011 (0.27) 0.005 (0.12) 0.032 (0.80) 0.032 (0.80) 0.020 (0.50) Revision: 19-Feb-16 Document Number: 89067 3 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000