XY2B-0002 XC6D/XC6H Press-fit Tools

■ XC6D/XC6H Press-fit
Tools (unit: mm)
Press-fit Tool
XY2B-0002
Attachment
XY2B-1005
Use the Press-fit Tool (XY2B-0002) with the XY2B1005 Attachment.
Model
XY2B-0002
XY2B-1005
■ Flat Cables (unit: mm)
1.27-mm Pitch/Flat Cables for XC6D
Connectors
XY3A-6401
Standard Cable
XY3A-6402
Folding Cable
XY3A-6403
Color-coded Cable
Contact area
Non-contact area
Core No.
Cable mark
Ordering Information (Order in 1-roll (61.0 m) units)
No. of cores
64
Standard
Cable
XY3A-6401
Folding Cable Color-coded
Cable
XY3A-6402
XY3A-6403
Applicable
Connector
XC6D-6421
Insulation
color
Core No.
Insulation
color
1
Brown
6
Blue
2
Red
7
Purple
3
Orange
8
Gray
4
Yellow
9
White
5
Green
10
Black
Note: The colors above repeat again from 11 cores.
Ratings and Characteristics
Item
XY3A-6401
XY3A-6402
XY3A-6403
Standard Cable Folding Cable Color-coded Cable
UL file No.
UL2651
UL20012
Max. operation voltage
300 V
150 V
UL20028
150 V
Max. operation current
105°C
80°C
105°C
Max. conductor
resistance
224 Ω/km (at 20°C)
Conductor
AWG28 (7/0.127), tin plated,
soft copper wire
Dielectric strength
2,000 VAC 50/60 HZ for one min
Insulation
Heat-resistant vinyl
Materials
Min. insulation resistance 5 MΩ-km (at 20°C)
0.847-mm Pitch/Flat Cable for XC6H
Connectors
XY3A-9605
Ratings and Characteristics
Orange
Light gray
Ordering Information (Order in 1-roll
(61.0 m) units)
UL file No.
UL20028
Max. operation
voltage
150 V
Max. operation
current
105°C
Max. conductor
resistance
354 Ω/km (at 20°C)
2,000 VAC 50/60 HZ
for one min
No. of cores Model
Applicable
Connector
Dielectric
strength
96
XC6H-9621
Min. insulation re- 5 MΩ-km (at 20°C)
sistance
XY3A-9605
Materials
4
DIN Connectors (Cable Connecting) XC6
Conductor
AWG30 (7/0.102), tin plated,
soft copper wire
Insulation
Heat-resistant vinyl