Datasheet

UNISONIC TECHNOLOGIES CO., LTD
U74AC32
CMOS IC
QUADRUPLE 2-INPUT
POSITIVE-OR GATE

DESCRIPTION
The U74AC32 is a quad 2-input positive-OR gate. The device
performs the Boolean function Y=A+B or Y  A  B in positive
logic.

FEATURES
* Operation Voltage Range: 2~6V
* Inputs Accept Voltages to 6V
* Max tpd of 7.5 ns at 5V

ORDERING INFORMATION
Ordering Number
U74AC32G-S14-R
U74AC32G-P14-R

Package
SOP-14
TSSOP-14
Packing
Tape Reel
Tape Reel
MARKING
SOP-14
TSSOP-14
14 13 12 11 10 9
8
UTC
U74AC32G
1
www.unisonic.com.tw
Copyright © 2015 Unisonic Technologies Co., Ltd
2 3
4
5
6
7
Date Code
Lot Code
1 of 5
QW-R502-988.B
U74AC32


CMOS IC
PIN CONFIGURATION
FUNCTION TABLE(EACH GATE)
INPUTS
OUTPUT
A
B
Y
H
X
H
X
H
H
L
L
L
L: low voltage level; H: high voltage level; X: don’t care

LOGIC DIAGRAM,EACH GATE (POSITIVE LOGIC)
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 5
QW-R502-988.B
U74AC32

CMOS IC
ABSOLUTE MAXIMUM RATING (unless otherwise specified) (Note 2)
PARAMETER
SYMBOL
RATINGS
UNIT
Supply Voltage
VCC
-0.5~7.0
V
Input Voltage
VIN
-0.5~Vcc+0.5
V
Output Voltage
VOUT
-0.5~VCC+0.5
V
Input Clamp Current (VI<0 or VI>VCC )
IIK
±20
mA
Output Clamp Current (VO<0 or VO>VCC)
IOK
±20
mA
Output Current(VO=0 to VCC)
IOUT
±50
mA
Continuous current through VCC or GND
ICC
±200
mA
Storage Temperature
TSTG
-65 ~ +150
°C
Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied
2. The input and output voltage ratings may be exceeded if the input and output current ratings are
observed.

THERMAL DATA
PARAMETER
Junction to Ambient

SYMBOL
SOP-14
TSSOP-14
θJA
UNIT
°С/W
°С/W
RECOMMENDED OPERATING CONDITIONS
PARAMETER
Supply Voltage
Input Voltage
Output Voltage
Operating free-air temperature
Input Transition Rise or Fall Rate

RATINGS
86
113
SYMBOL
VCC
VIN
VOUT
TA
∆t/∆v
MIN
2
0
0
-40
TYP
MAX
6
Vcc
Vcc
85
8
UNIT
V
V
V
°C
ns/V
ELECTRICAL CHARACTERISTICS (TA=25°C, unless otherwise specified)
PARAMETER
SYMBOL
HIGH-level input voltage
VIH
LOW-lever output voltage
VIL
High-Level Output Voltage
VOH
Low-Level Output Voltage
VOL
Input Leakage Current
Quiescent Supply Current
Input Capacitance
II
ICC
CI
TEST CONDITIONS
VCC=3V
VCC=4.5V
VCC=5.5V
VCC=3V
VCC=4.5V
VCC=5.5V
VCC=3V, IOH=-50μA
VCC=4.5V, IOH=-50μA
VCC=5.5V, IOH=-50μA
VCC=3V, IOH=-12mA
VCC=4.5V, IOH=-24mA
VCC=5.5V, IOH=-24mA
VCC=3V, IOH=50μA
VCC=4.5V, IOH=50μA
VCC=5.5V, IOH=50μA
VCC=3V, IOH=12mA
VCC=4.5V, IOH=24mA
VCC=5.5V, IOH=24mA
VI=VCC or GND, VCC=5.5V
VI=GND or VCC, IO=0, VCC=5.5V
VI=VCC or GND, VCC=5V
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
2.1
3.15
3.85
TYP
MAX
UNIT
V
0.9
1.35
1.65
2.9
4.4
5.4
2.56
3.86
4.86
V
V
0.002
0.001
0.001
2.6
0.1
0.1
0.1
0.36
0.36
0.36
±0.1
2
V
μA
μA
pF
3 of 5
QW-R502-988.B
U74AC32

CMOS IC
DYNAMIC CHARACTERISTICS
(CL=50pF, RL=500Ω, TA=25°C, unless otherwise specified) (see Figure 1)
PARAMETER
SYMBOL
TEST CONDITIONS
VCC=3.3V±0.3V
tPLH
VCC=5V±0.5V
Propagation delay from
Input(A or B) to Output(Y)
VCC=3.3V±0.3V
tPHL
VCC=5V±0.5V

MIN
1.5
1.5
1.5
1.5
TYP
7
5.5
7
5
MAX
9
7.5
8.5
7
UNIT
ns
ns
ns
ns
MAX
UNIT
pF
OPERATING CHARACTERISTICS (VCC=5V,TA=25°C, unless otherwise specified)
PARAMETER
Power Dissipation Capacitance
SYMBOL
CPD
TEST CONDITIONS
CL=50pF, f =1MHz
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
TYP
40
4 of 5
QW-R502-988.B
U74AC32

CMOS IC
TEST CIRCUIT AND WAVEFORMS
Notes: 1. CL includes probe and jig capacitance.
2. All input pulses are supplied by generators having the following characteristics:
PRR≤1MHZ, ZO=50Ω, tr≤2.5ns,tf≤2.5ns.
3. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 5
QW-R502-988.B