Downloads for Autotransformer Power Transformers (N-150MG)

P OWE R T RAN S FO R M E R
CHASSIS MOUNT : Autotransformer
N-150MG
Electrical Specifications (@25ºC)
1. Maximum Power:
150 VA
2. Input Voltage:
115 V, 50 / 60 Hz
3. Output Voltage:
230V + 5%
4. Full Secondary Load: 0.65 Amps RMS
Description:
The N-150MG is part of the line of Auto-Transformers that are single winding
transformers in which the primary coil is a fraction of the entire winding for
voltage step-up. This causes part of the power to be transferred conductively
through the windings, rather than all of the power being transferred by
induction.
A
Safety:
These units are designed with 1500V isolation between the winding and the
core. Materials and construction are rated for Class B insulation system.
C
Dimensions:
Unit: In inches
A
B
C
D
E
3.594
2.968
3.312
2.250
2.125
Weight: 4.90 lbs
Mounting Holes: 0.375 x 0.187
Connection: 6 ft. long cord with NEMA 5-15P Plug, 1 ft. long cord with NEMA
6-15P socket.
B
Schematic:
D
BLK
FN
BLK
115 V
WHT
WHT
E
230 V
GRN
ST
GRN
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: May 11, 2015