Electrical Specifications (@25ºC)
1. Maximum Power:
250 VA
2. Input Voltage:
115 V, 50 / 60 Hz
3. Output Voltage:
230V + 5%
4. Full Secondary Load: 1.10 Amps RMS
Description:
The N-250MG is part of the line of Auto-Transformers that are single winding
transformers in which the primary coil is a fraction of the entire winding for
voltage step-up. This causes part of the power to be transferred conductively
through the windings, rather than all of the power being transferred by
induction.
A
Safety:
These units are designed with 1500V isolation between the winding and the
core. Materials and construction are rated for Class B insulation system.
C
Dimensions:
Unit: In inches
A
B
C
D
E
3.875
3.250
3.687
2.50
2.437
Weight: 6.60 lbs
Mounting Holes: .203 x .375
Connection: 6 ft. long cord with NEMA 5-15P Plug, 1 ft. long cord with NEMA
6-15P socket.
B
Schematic:
D
BLK
FN
BLK
115 V
WHT
WHT
E
230 V
GRN
ST
GRN
RoHS Compliance: As of manufacturing date February 2005, all standard products