P OWE R T RAN S FO R M E R CHASSIS MOUNT : Autotransformer N-2X Electrical Specifications (@25ºC) 1. Maximum Power: 100 VA 2. Input Voltage: 230 V, 50 / 60 Hz 3. Output Voltage 115V, + 5% 4. Full Secondary Load 0.87 Amps RMS 5. Temperature Rise: 60C TYP ( 85C MAX allowed) from 25º C, Ambient Construction: Single winding on a double wall, nylon bobbin. This chassis mount design comes in a channel frame with .187” diameter holes in the mounting ears. Three leads exit the transformer, the black lead is the tap. Description: Secondary coil is a fraction of the entire winding for voltage step-down. This causes part of the power to be transferred conductively through the windings, rather than all of the power being transferred by induction. .187 DIA. 2 HOLES Safety: These units are designed with 1500V isolation between the winding and the core. Materials and construction are rated for Class B insulation system. 4.0 RE F 3.562 +/-.030 E50476 A. Dimensions: Unit: In inches H W D A B C T MW ML 2.562 4.0 1.93 2-5/16 1-1/8 5/16 3/16 3.562 - B. RE F 1.93 Lead Connections: Red Primary (230V) to Red Wht N-2X Black RE F 2.562 Secondary (115V) Wht to Black White C. Weight : 2.1 lbs W H T BLK R E D RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing,this document is considered”uncontrolled”.Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: May 11, 2015