P OWER TRANS FOR MER CHASSIS MOUNT : Autotransformer N-1X Electrical Specifications (@25ºC) 1. Maximum Power: 50 VA 2. Input Voltage: 230 V, 50 / 60 Hz 3. Output Voltage: 115V + 5% 4. Full Secondary Load: 0.87 Amps RMS Construction: Single winding on a double wall, nylon bobbin. This chassis mount design comes in a channel frame with .187” diameter holes in the mounting ears. A Unit: In inches A B C D 2.281 3.687 2.00 3.125 RED Dimensions: BLK/RED Safety: These units are designed with 1500V isolation between the winding and the core. Materials and construction are rated for Class B insulation system. BLK Description: Secondary coil is a fraction of the entire winding for voltage step-down. This causes part of the power to be transferred conductively through the windings, rather than all of the power being transferred by induction. B D Weight: 1.5 lbs Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin 230V 115V OV .187 DIA (REF) Schematic: RED BLK/RED 2 HOLES C BLK For 230V input: Blk to Red For 115 output: Blk to Blk/Red RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013