SP240 series

SP240
2 4 0 W S i n g l e O u t put Switching Power Supply with PFC
series
Universal AC input
Built-in active Power Factor Correction (PFC)
Protections: Short circuit / Overload / Over voltage / Over
temperature
Forced air cooling by built-in DC fan
Built in cooling FAN ON-OFF control
LED indicator for power on
Fixed switching frequency at 90KHz
Model Number Output Volts Output Amps OVP
Min Load DC Volt Adjust Efficiency Line Regulation
SINGLE OUTPUT
SP240-5
SP240-7.5
SP240-12
SP240-15
SP240-24
SP240-30
SP240-48
5 Volts(DC)
7.5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
30 Volts(DC)
48 Volts(DC)
WWW.ASTRODYNE.COM
45 Amps
32 Amps
20 Amps
16 Amps
10Amps
8 Amps
5 Amps
6.3~ 7.5Volt(DC)
9.4~ 10.9Volt(DC)
14.7 ~ 17.5Volt(DC)
19 ~ 22.5Volt(DC)
29.5 ~ 35Volt(DC)
34.7~ 41Volt(DC)
57.6~ 67.2Volt(DC)
0~45Amps
0~32Amps
0~20Amps
0~16Amps
0~10Amps
0~8Amps
0~5Amps
4~6Volt(DC)
79%
6~9Volt(DC)
83%
10~14Volt(DC) 86%
12~18Volt(DC)
86%
20~28Volt(DC)
87%
27~33Volt(DC)
88%
41~56Volt(DC)
89%
±0.5%
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SP240
2 4 0 W S i n g l e O u t put Switching Power Supply with PFC
INPUT SPECIFICATIONS
Input Voltage Range
88~264VAC; 124~370 Volts(DC)
Frequency Range
47-63 Hz
Inrush Current, typ: (cold start) 25 Amps/115VAC; 40 Amps/230VAC
Input Current
3.6 Amps/115VAC; 1.8Amps/230VAC
Leakage current
< 2mAmps / 240VAC
Min Load
See Selection Chart
Power Factor @ FL
> 0.95 / 230VAC
> 0.98 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Line Regulation
See Selection Chart
Load Regulation
±1%: 5 & 7.5V; ±0.5% 12-48V O/P
Voltage Tolerance (Note 2) ±2%: 5 & 7.5V; ±1% 12-48V O/P
Ripple/Noise (Note 1)
150mVpk-pk
Hold Up Time @ FL
20mS typ.
Setup/Rise Time @ FL
800/50mS @ 230VAC
1500/50mS @ 115VAC
Over Voltage Protection See Selection Chart
Shutdown, re-power
Over Current Protection 105~135% rated output power
Hiccup mode, auto recovers
Over Temp. Protection
90°C±5°C, 5 & 7.5V O/P
85°C±5°C, 12-48V O/P
DC Volt Adjust
See Selection Chart
Fan Control
RTH2≥ 40°C FAN ON
≤ 35°C FAN OFF, typ.
EMS
series
1500VAC Input - Ground
500VAC Output - Ground
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024
ENV50204, light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-20°C to +70°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20~90% RH non cond
±0.03% / °C (0-50°C) 284KHrs MIL-HDBK-217F(25°C)
10~500Hz, 2G 10min./1cycle
60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Weight
190x 93 x 50mm (7.48”x3.66 ”x1.97”)
28.22 oz (800g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
EMI
Harmonic Current
Efficiency
Isolation
UL60950-1, TUV EN60950-1 Approved
≥ 100MΩ / 500V / 25°C / 70% RH
Compliance to EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
See Selection Chart
3000VAC Input - Output
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
2 4 0 W S i n g l e O u t put Switching Power Supply with PFC
SP240
series
MECHANICAL DIMENSIONS
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458