PS65 6 5 W S i n g l e O u t put Switching Power Supply series Universal AC input Protections:Short circuit/Over load/Over voltage Low leakage current <0.5mA Cooling by free air convention Fixed switching frequency at 65KHz Model Number Output Volts Output Amps OVP 3.3 Volts(DC) 5 Volts(DC) 7.5 Volts(DC) 12 Volts(DC) 13.5 Volts(DC) 15 Volts(DC) 24 Volts(DC) 27 Volts(DC) 48 Volts(DC) 12 Amps 12 Amps 8.0 Amps 5.2 Amps 4.7 Amps 4.2 Amps 2.7 Amps 2.4 Amps 1.35 Amps 3.8 ~ 4.46Volt(DC) 5.75 ~ 6.75Volt(DC) 8.63 ~ 10.1Volt(DC) 13.8 ~ 16.2Volt(DC) 15.5 ~ 18.2Volt(DC) 17.25 ~ 20.25Volt(DC) 27.6 ~ 32.4Volt(DC) 31~ 36.45Volt(DC) 55.2~ 64.8Volt(DC) Min Load DC Volt Adjust Load Reg Efficiency SINGLE OUTPUT PS65-3.3 PS65-5 PS65-7.5 PS65-12 PS65-13.5 PS65-15 PS65-24 PS65-27 PS65-48 WWW.ASTRODYNE.COM 0~15.2Amps 0~13.8Amps 0~9.6Amps 0~6.0Amps 0~5.4Amps 0~4.8Amps 0~3.0Amps 0~2.7Amps 0~1.5Amps 3.14~3.63Volt(DC) 4.75~5.5Volt(DC) 7.13~8.25Volt(DC) 11.4~13.2Volt(DC 12.8~14.9Volt(DC) 14.25~16.5Volt(DC) 22.8~26.4Volt(DC) 25.65~29.7Volt(DC) 45.6~52.8Volt(DC) ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% 69% 76% 79% 79% 79% 79% 80% 80% 80% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 PS65 6 5 W S i n g l e O u t put Switching Power Supply INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current Min Load 90 ~ 264VAC 127~370 Volts(DC) 47-440Hz 20Amps/115VAC; 40Amps/230VAC 1.2 Amps@115VAC 0.72 Amps@230VAC < 0.5mAmps / 240VAC See Selection Chart OUTPUT SPECIFICATIONS Voltage and Current Line Regulation Load Regulation Voltage Tolerance (Note 2) Ripple/Noise (Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Voltage Protection Over Current Protection DC Voltage Adjust See Selection Chart ±1.0% See Selection Chart 3.0%: 3.3~7.5Volts(DC) 2.0%: 12~48Volts(DC) 80mVpk-pk: 3.3Volts(DC) 100mVpk-pk: 5~48Volts(DC) 60mS 800mS, 20mS See Selection Chart Hiccup mode, auto recover 3.3Volts: 36~55W 5Volts: 70~105W 7.5~48Volts: 73~105W rated output power Hiccup mode, auto recover See Selection Chart series Harmonic Current Compliance to EN61000-3-2,-3 Efficiency See Selection Chart Isolation 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground EMS Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, ENV55024 light Industry Level, Criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -10°C to +60°C (See Derate Curve) -20°C to +85°C, 10~95% RH 20~90% RH non cond ±0.04% / °C (0-50°C) 300.7KHrs min,MIL-HDBK-217F(25°C) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Weight 127 x 76 x 42 mm (5”x 3”x 1.65”) 7.41 oz (210g) Note 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Mounting holes M1 and M2 should be grounded for EMI purposes. GENERAL SPECIFICATIONS Safety Insulation Resistance EMI UL60950, TUV EN60950-1 Approved ≥ 100MΩ / 500Volts(DC) Compliance to EN55022 (CISPR22) Class B All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 6 5 W S i n g l e O u t put Switching Power Supply WWW.ASTRODYNE.COM PS65 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 6 5 W S i n g l e O u t put Switching Power Supply WWW.ASTRODYNE.COM PS65 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458