Download

LoPAC™ Family
PFC Mini, PFC Micro, PFC MicroS
Power Factor Corrected, AC-DC Switchers
Family Features
•
•
•
•
•
•
•
•
•
•
•
•
Near unity power factor
EN61000-3-2 harmonic current compliance
Low profile package
Output power to 1,500 W
Up to 6 user specifiable outputs
Universal AC input
Power density up to 11 W/in3
Integral cooling fans
Autosense
Safety agency approvals: CE Marked, cTÜVus
Vantage Line [a]
RoHS compliant
Overview
PFC Mini
12.20" x 6.00" x 1.72"
309,9 x 152,4 x 43,6 mm
Up to 1,500 W
1 to 6 Outputs
The PFC MicroS, PFC Micro and PFC Mini are
members of the low profile, high-density
LoPAC series of power factor corrected
AC-DC power supplies. Available as a one,
two or three slot package, respectively, each
LoPAC slot can be configured with standard
Vicor DC-DC converter modules enabling up
to six user specifiable isolated outputs in a
package only 1.72'' (43,6 mm) high with a
power density of 11 W/in3.
PFC Micro
10.40" x 5.06" x 1.86"
264,1 x 128,5 x 47,3 mm
Up to 800 W
1 to 6 Outputs
For maximum versatility and flexibility, the
LoPAC can be configured with VI-26x (full
brick), VI-J6x (half brick) or Maxi, Mini,
Micro V375 Series full, half and quarter brick
modules. These modules cover the entire range
of outputs from 1 to 100 Vdc and 25 to 600
Watts. The optimum solution can be factory
configured based on your exact voltage and
power requirements.
For conducted EMI, the LoPACs meet FCC
Class A and B. Certain configurations meet
EN55022 Class A and B (consult factory).
Harmonic current limits per EN61000-3-2 and
Surge Immunity per EN61000-4-5, in addition
to a wide variety of safety agency approvals,
further enhance the LoPAC flexibility.
PFC MicroS
7.95" x 5.06" x 1.86"
201,9 x 128,5 x 47,3 mm
Up to 600 W
1 to 3 Outputs
[a]
The Vantage Line is Vicor's affordable
power supply option. Minor variances in some
specifications between the Vantage Line and
the Standard Line apply. Contact factory for
more information.
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 1 of 8
03/2015
800 927.9474
PFC Mini, PFC Micro, PFC MicroS
DC Output Selections
The versatility of the LoPAC series is due, in large part, to the
wide array of Vicor modules available to be configured into the
different package formats. Slots can be populated with VI-200,
VI-J00 or Maxi, Mini, Micro modules in full, half or quarter
brick sizes. Vicor’s full VI-26x, VI-J6x and V375 standard
product matrices are available to choose from.
In addition, the full range of non-standard voltages and powers
from 1 to 100 Vdc and 10 to 600 W is also available for
inclusion. The table below is just a sampling of some of the
most popular standard outputs that can be configured into
LoPAC slots.
Available Power (W) per Package Size
Output
Voltage
Maxi
2Vdc
160
VI-200
Mini
80
60
100
VI-J00
Micro
40
30
50
3.3Vdc
264
132
99
150
66
50
75
5Vdc
400
200
150
200
100
75
100
12Vdc
600
200
150
300
100
75
150
15Vdc
600
200
150
300
100
75
150
24Vdc
600
200
150
300
100
75
150
28Vdc
600
200
150
300
100
75
150
48Vdc
600
200
150
300
100
75
150
LoPAC Slot Configurations
The DC-DC converter modules are used to populate each
LoPAC converter slot. Each slot can be configured in different
ways depending on module sizes and power limitations.
The following table summarizes the available slot
configurations for each of the three LoPAC packages.
Maximum Output Power
Model
Type
# Slots
@ 230 Vac
Total
@ 115 Vac
Modules per Slot
PFC Mini
PFC Micro
PFC MicroS
3
2
1
1,500 W
800 W
600 W
800 W
500 W
500 W
1 Full or 2 Half
1 Full or 2 Half or 3 Quarter
1 Full or 2 Half or 3 Quarter
Autosense Feature*
This feature is implemented in all converter slots in the LoPAC
family. If remote sense connections are not needed or are
inadvertently not made, no local sense connections are
necessary. Simply connect the output(s) to the load and the
*Applies
converter(s) will automatically operate in the local sense mode.
If remote sense connections are made, the unit will operate in
remote sense mode.
to converter slots utilizing Maxi or Mini size converters.
Part Numbering
PM
Product Prefix
PM PFC Mini
PC PFC Micro
PS PFC MicroS
*
X1
-
X2
X3
X4
Number of
VI-200 / VI-J00 module(s)
Number of
Output
Voltages
Number of
Maxi / Mini / Micro module(s)
Refer to Design Guide for more on the optional codes.
XXXX
Factory
Assigned
Optional Factory
Assigned
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 2 of 8
03/2015
800 927.9474
- X5
- X6
Optional Factory
Assigned
2 = FasTrak
G = RoHS
LL
QF
Optional Codes*
Low Leakage
Quiet Fan
(only available on PFC Mini)
PFC Mini, PFC Micro, PFC MicroS
Performance Specifications
The following are typical performance specifications at room
ambient temperature, nominal line voltage (115/230Vac) and
75% load on all outputs, unless specified otherwise. For detail
INPUT CHARACTERISTICS
Parameter
AC Input
Voltage
Frequency (Standard)
Frequency (Vantage)
DC Input
Line Regulation
Inrush Current
@ 115Vac
@ 230Vac
Ride Through Time
@ load
Conducted EMI/RFI
Power Factor
Harmonic Current Limits
Transient Burst Immunity
PFC Mini
PFC Micro
100 – 380
8.5
17
7
14
> 20
1,200
FCC Class A
EN55022 Class A
EN61000-4-4
Temperature Regulation
Long Term Drift
Output Ripple & Noise
≤10Vout
>10Vout
Voltage Trim Range
VI-200/VI-J00 Slots
Maxi, Mini, Micro Slots
Remote Sense Compensation
OVP Set Point
Current Limit
500
FCC Class A
EN55022 Class A (consult factory)
> 0.98
EN61000-3-2/A14
EN61000-4-4
Units
Vac
Hz
Hz
Vdc
%
2,121
4,242
750
PFC Mini
Notes
From low line to high line
A pk
A pk
ms
W
Certain configurations meet
FCC & EN Class B
>75% load
Class A
Level 3, Performance Criteria B
Installation Class 3,
Performance Criteria B
EN61000-4-5
Dielectric Withstand
Primary to Chassis GND
Primary to Secondary
Secondary to Chassis GND
Load Regulation
PFC MicroS
85 – 264
47 – 500
47 – 63
100 – 300
0.4
Surge Immunity
OUTPUT CHARACTERISTICS
Parameter
Setpoint Accuracy (Standard)
Setpoint Accuracy (Vantage)
specifications, consult the Design Guide for the LoPAC
configuration of interest. This is available on our
website (vicorpower.com).
Vdc
Vdc
Vdc
PFC Micro
PFC MicroS
1 % (Standard) 2% (Special)
2 % (Standard) 5% (Special)
0.05
0.2
0.005
0.02
Units
Notes
% of Vnom
%
%
%/°C
%/khr
10% to full load
No load to full load
– 20º to +65ºC
100
1.0
mV
% Vout
20 MHz bandwidth
20 MHz bandwidth
50 – 110
10 – 110
0.5
125
115
% Vout
% Vout
Vdc
% Vout
% Imax
±10% on 10 – 15 Vout
Preload may be required
Autosense (See page 2)
Not available on VI-J00 modules
Auto recovery
ENVIRONMENTAL CHARACTERISTICS
Parameter
PFC Mini
PFC Micro
PFC MicroS
Units
Notes
Storage Temperature
– 40 to +85
°C
Operating Temperature
Full Rated Power (Standard)
– 20 to +45
°C
50% Rated Power (Standard)
– 20 to +65
°C
Full Rated Power (Vantage)
0 to +45
°C
50% Rated Power (Vantage)
0 to +65
°C
Vibration
MIL-STD-810E, Category 10, Minimum integrity test (PFC Mini only)
Safety Approvals
CE Marked, cTÜVus
MECHANICAL CHARACTERISTICS
Parameter
PFC Mini
PFC Micro
PFC MicroS
Units
Notes
5.5
5.2
3.1
lbs
Weight
2,5
2,4
1,4
kg
12.20 x 6.00 x 1.72
10.40 x 5.06 x 1.86
7.95 x 5.06 x 1.86
in
LxWxH
Overall Dimensions
309,9 x 152,4 x 43,6 264,1 x 128,5 x 47,3 201,9 x 128,5 x 47,3 mm
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 3 of 8
03/2015
800 927.9474
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 4 of 8
03/2015
800 927.9474
4
3
REF DESIGNATION LEGEND
MB = MOTHER BOARD
S1 = (SLOT 1) DAUGHTERBOARD MODULES E/D 1.
S2 = (SLOT 2) DAUGHTERBOARD MODULES E/D 2.
S3 = (SLOT 3) DAUGHTERBOARD MODULES E/D 3.
A COMPLETE SET OF MATING CONNECTORS CAN
BE PURCHASED FROMWESTCOR BY SPECIFYING
CONNECTOR KIT P/N: 19-130047
2 WITH OPTIONAL BUSBAR.
1. INTERPRET DRAWING PER ANSI Y14.5-1994.
NOTES: UNLESS OTHERWISE SPECIFIED
MBJ1 INPUT CONNECTIONS
MBJ1-1 EARTH GROUND
MBJ1-2 L2 / NEUTRAL
MBJ1-3 L1
14 AWG WIRE
CLAMPING SCREWS
3
J3 INTERFACE CONNECTION
MATING HDWR: (AMP P/N: OR EQUIVALENT)
HOUSING: AMP P/N: 205204-4
TERMINALS: AMP P/N: 66506-9
SCREW LOCK: AMP P/N: 205980-4
CRIMP TOOL: AMP 58448-3
J3 INTERFACE PIN OUT
5 1
J3-1
E/D-1
J3-2
E/D-2
9 6
J3-3
E/D-3
J3-4
SIGNAL GROUND
J3-5
VCC +5V 300mA
J3-6
ACOK AC POWER OK
J3-7
GSD GENERAL SHUTDOWN
J3-8
SPARE
J3-9
SPARE
0.487 12.36
0.920 23.37
1.72 ±0.02 43.69 ±0.51
4.00 101.60
1.00 25.40
2.210 56.13
1.600 40.64
5.268 133.81
SCALE: 1:2
BOTTOM VIEW
8.00 203.20
8.00 203.20
12.03 305.56
12.16 308.86
2
0.47 11.94
2.00 50.80
6.00 152.40
FOUR OUTPUT UNIT PICTURED
(SEE PAGE 7 FOR DETAILED OUTPUT
CONNECTION INFORMATION .)
0.34 ±0.02 8.64 ±0.51
CUSTOMER MOUNTING HOLES:
2X #8-32 X 0.156 or M4 X 4mm MAX LG.
FROM OUTSIDE OF POWER SUPPLY
CUSTOMER MOUNTING HOLES:
4X #8-32 X .156 or M4 X 4mm MAX LG.
FROM OUTSIDE OF POWER SUPPLY
2.00 50.80
12.49 ±0.02 317.29 ±0.51
PFC MINI
PFC Mini, PFC Micro, PFC MicroS
Mechanical Drawing, PFC Mini
REF
SGND
PGR
ACOK
ED6
ED5
ED4
ED3
ED2
ED1
GSD
PGDV
Vcc
PIN
CBJ3-1
CBJ3-2
CBJ3-3
CBJ3-4
CBJ3-5
CBJ3-6
CBJ3-7
CBJ3-8
CBJ3-9
CBJ3-10
CBJ3-11
CBJ3-12
CBJ3 INTERFACE CONNECTOR
SIGNAL GROUND
POWER GOOD/READ
AC POWER OK
ENABLE/DISABLE S2M3
ENABLE/DISABLE S2M2
ENABLE/DISABLE S2M1
ENABLE/DISABLE S1M3
ENABLE/DISABLE S1M2
ENABLE/DISABLE S1M1
GENERAL SHUTDOWN
POWER GOOD/DATA VALID
+5V@40mA
DESCRIPTION
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 5 of 8
03/2015
800 927.9474
REFERENCE
MB
CB
S(x)
M(x)
A COMPLETE SET OF MA TING CONNECTORS I S AVAILABLE BY
SPECIFYING WESTCOR CONNECTOR KIT P/N: 19-130044
WITH OPTIONAL BUS BAR
DIMENSIONS SHOWN ARE FROM BOTTOM SURFACE.
MOUNTING PEMNUTS EXTEND .010 PAST BOTTOM SURFACE
2
3
4
DESIGNATIONS
MOTHER BOARD
CONTROL BOARD
SLOT NUMBER
MODULE NUMBER
FLOW
1.29 32,69
3
7.500 190,50
MOUNTING HOLES; 2 PLACES
USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH
FROM OUTSIDE OF UNIT
10.65±0.02 270,46±0,51
10.40 264,11
7.500 190,50
AIR
10.24 260,02
0.16 4,09
MOUNTING HOLES; 2 PLACES
USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH
FROM OUTSIDE OF UNIT
7.500 190,50
1.29 32,69
MBJ1 (5 PIN) MBJ1 A/C INPUT 2
MATING CONNECTOR:
L1
HOUSING: MOLEX (39-01-4051)
N/C
TERMINAL: MOLEX (39-00-0090)
L2/N
CRIMP TOOL: MOLEX (11-01-0199)
N/C
GND
PIN-1
CBJ3 (12 PIN)
1.29 32,69
1 S2
SIX OUTPUT UNIT PICTURED
(SEE PAGE 7 FOR DETAILED OUTPUT
CONNECTION INFORMATION . )
MOUNTING HOLES; 4 PLACES
USE 8-32 X 0.12 or M4 X 3MM MAX LENGTH
FROM OUTSIDE OF UNIT
0.71 18,03
3.500 88,90
3
1 S1
5.06 128,52
4 1.86 47,29
0.25±0.02 6,35±0,51
1.22 31,04 4
4
1.22 31,04
Mechanical Drawing, PFC Micro
1
NOTES: UNLESS OTHERWISE SPECIFIED
2 MATING CONNECTOR:
HOUSING: MOLEX (50-57-9412)
SOCKET CRIMP 24-30 AWG: MOLEX (16-02-0097)
CRIMP TOOL: MOLEX (11-01-0209)
1
PFC MICRO
PFC Mini, PFC Micro, PFC MicroS
SGND
PGR
ACOK
N/C
N/C
N/C
ED3
ED2
ED1
GSD
PGDV
Vcc
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 6 of 8
03/2015
800 927.9474
REFERENCE
MB
CB
S(x)
M(x)
A COMPLETE SET OF MATING CONNECTORS IS AVAILABLE
BY SPECIFYING WESTCOR CONNECTOR KIT P/N: 19-130044
DIMENSIONS SHOWN ARE FROM BOTTOM SURFACE.
MOUNTING PEMNUTS EXTEND .010 PAST BOTTOM SURFACE.
2
3
DESIGNATIONS
MOTHER BOARD
CONTROL BOARD
SLOT NUMBER
MODULE NUMBER
MBJ1 A/C INPUT
2
1.29 32,69
FLOW
AIR
0.16 4,09
1.29 32,69
1.29 32,82
MATING CONNECTOR:
L2/N HOUSING: MOLEX (39-01-4051)
TERMINAL: MOLEX (39-00-0090)
GND CRIMP TOOL: MOLEX (11-01-0199)
L1
1
N/C
PIN 1
MBJ1 (5 PIN)
CBJ3 (12 PIN)
N/C
SIGNAL GROUND
POWER GOOD/READ
AC POWER OK
N/C
N/C
N/C
ENABLE/DISABLE S1M3
ENABLE/DISABLE S1M2
ENABLE/DISABLE S1M1
GENERAL SHUTDOWN
POWER GOOD/DATA VALID
+5V@40mA
MATING CONNECTOR:
HOUSING: MOLEX (50-57-9412)
TERMINAL: MOLEX (16-02-0097)
CRIMP TOOL: MOLEX (11-01-0209)
CBJ3-1
CBJ3-2
CBJ3-3
CBJ3-4
CBJ3-5
CBJ3-6
CBJ3-7
CBJ3-8
CBJ3-9
CBJ3-10
CBJ3-11
CBJ3-12
CBJ3 E/D INTERFACE CONNECTOR
PIN
REF
DESCRIPTION
NOTES: UNLESS OTHERWISE SPECIFIED
2
1
PFC MICROS
5.100 129,54
MOUNTING HOLES; 2 PLACES
USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH
FROM OUTSIDE OF UNIT
5.100 129,54
7.95 201,88
MOUNTING HOLES; 2 PLACES
USE 8-32 X 0.25 or M4 X 6MM MAX LENGTH
FROM OUTSIDE OF UNIT
5.100 129,54
1.22 31,04
3
MOUNTING HOLES 4 PLACES
USE 8-32 X 0.12 or M4 X 3MM LENGTH
FROM OUTSIDE OF UNIT
0.71 18,03
1 S1
3 1.86 47,29
3
5.06 128,52
3.500 88,90
1.22 31,04
TRIPLE OUTPUT UNIT PICTURED
(SEE PAGE 7 FOR DETAILED OUTPUT
CONNECTION INFORMATION).
PFC Mini, PFC Micro, PFC MicroS
Mechanical Drawing, PFC MicroS
PFC Mini, PFC Micro, PFC MicroS
Output Connections for the PFC Mini, PFC Micro and PFC MicroS
A. OUTPUT STUDS - SINGLE OUTPUT
(when populated with Full Brick modules)
PFC Mini, PFC Micro and PFC MicroS
–V OUT
10-32 OUTPUT STUDS
SxJ2 REMOTE SENSE/TRIM
PIN CONNECTOR
– REMOTE SENSE
+ REMOTE SENSE
TRIM
3
2
1
+V OUT
MATING CONNECTOR:
HOUSING: MOLEX (50-57-9403)
TERMINAL FEMALE CRIMP 22-24 AWG: MOLEX (16-02-0103)
USE CRIMP TOOL: MOLEX (11-01-0208)
B. MOLEX CONNECTOR - SINGLE OR DUAL OUTPUT
(when populated with Half Brick modules)
PFC MINI 18 Pin Housing
PFC MICRO 18 Pin Housing
SxJ1 (18 PIN OUTPUT, REMOTE SENSE
AND TRIM PIN CONNECTOR)
SxJ1 (18 PIN OUTPUT, REMOTE SENSE
AND TRIM PIN CONNECTOR)
9 18
8 17
7 16
6 15
5 14
4 13
3 12
2 11
1 10
PIN
1
2
3
4
5
6
7
8
9
DESCRIPTION
+ V OUT M2
– V OUT M2
– V OUT M2
+ SENSE M2
– SENSE M2
TRIM M1
+ V OUT M1
+ V OUT M1
– V OUT M1
PIN
10
11
12
13
14
15
16
17
18
DESCRIPTION
+ V OUT M2
+ V OUT M2
– V OUT M2
+ SENSE M1
TRIM M2
– SENSE M1
+ V OUT M1
– V OUT M1
– V OUT M1
9 18
8 17
7 16
6 15
5 14
4 13
3 12
2 11
1 10
PIN
1
2
3
4
5
6
7
8
9
DESCRIPTION
+ V OUT M1
– V OUT M1
– V OUT M1
+ SENSE M1
– SENSE M1
TRIM M2
+ V OUT M2
+ V OUT M2
– V OUT M2
PIN
10
11
12
13
14
15
16
17
18
DESCRIPTION
+ V OUT M1
+ V OUT M1
– V OUT M1
+ SENSE M2
TRIM M1
– SENSE M2
+ V OUT M2
– V OUT M2
– V OUT M2
MATING CONNECTOR:
18 PIN HOUSING: MOLEX (39-01-2180)
TERMINAL FEMALE CRIMP 18-24 AWG: MOLEX 39-00-0039)
USE CRIMP TOOL: MOLEX (11-01-0197)
*PFC MicroS dual output slot configuration uses the
type A stud connection for both outputs.
3-pin connector designators are S1J1 and S1J2.
C. MOLEX CONNECTOR - SINGLE, DUAL OR TRIPLE OUTPUT
(when populated with Quarter Brick modules)
PFC Micro and PFC MicroS
SxJ1 (16 PIN OUTPUT, REMOTE SENSE
AND TRIM PIN CONNECTOR)
8 16
7 15
6 14
5 13
4 12
3 11
2 10
1 9
PIN
1
2
3
4
5
6
7
8
DESCRIPTION
+V OUT M3
–V OUT M3
TRIM M3
+V OUT M2
–V OUT M2
TRIM M2
+V OUT M1
–V OUT M1
PIN
9
10
11
12
13
14
15
16
DESCRIPTION
+V OUT M3
–V OUT M3
N/C
+V OUT M2
–V OUT M2
TRIM M1
+V OUT M1
–V OUT M1
The following accessories are available for the
LoPAC units:
Connector Kits
A complete set of mating hardware for all
combinations of input & output connections
PFC Mini
PFC Micro & PFC MicroS
MATING CONNECTOR:
16 PIN HOUSING: MOLEX (39-01-2160)
TERMINAL FEMALE CRIMP 18-24 AWG: MOLEX (39-00-0039)
USE CRIMP TOOL: MOLEX (11-01-0197)
Current Share Boards
Used for current sharing between identical LoPAC Models
for increased output power or redundancy
LoPACs with VI-200/VI-J00 Modules
LoPACs with Maxi, Mini, Micro Modules
19-130047
19-130044
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 7 of 8
03/2015
800 927.9474
CSB01
CSB02
PFC Mini, PFC Micro, PFC MicroS
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
LoPAC™ Family
Rev 2.4
vicorpower.com
Page 8 of 8
03/2015
800 927.9474