Product data sheet

Product datasheet
OT 60/170…240/1A0 4DIMLT2 E
OPTOTRONIC | Constant current LED power supplies with 4DIM/DALI
Areas of application
_ Street and urban lighting
_ Industry
_ Suitable for outdoor applications in luminaires with IP >
54
_ Suitable for use in outdoor luminaires of protection class
I and II
__
Product benefits
_ 4DIM functionality in one device (StepDIM, AstroDIM, MainsDIM, DALI)
_ Very high efficiency and reliability
_ High surge protection: up to 10 kV (1 pulse) / 8 kV, in protection class I or II
_ Low luminous efficacy tolerance through low output current tolerance of ± 3 %
_ Great flexibility due to wide operating temperature range of -40…55 °C or 60 °C
_ Protection through double isolation between mains input and LED output
Product features
_ Available with different wattage: 40 W, 60 W, 90 W, 165 W
_ Input voltage: 120…277 V (40 W), 220…240 V (60 W, 90 W, 165 W)
_ Current output range: 70…1,050 mA
_ Flexible current setting with one additional wire (LEDset2)
_ AstroDIM for autonomous dimming with five independent levels (astro, time mode)
_ Allows for energy saving in twilight phases
_ MainsDIM function for dimming via reduction of line voltage amplitude
_ Isolated DALI interface for bidirectional telemanagement systems
_ Standby power consumption: < 0.5 W
_ Constant lumen function
_ Overtemperature protection via external NTC
June 17, 2016, 11:43:50
OT 60/170…240/1A0 4DIMLT2 E
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 6
Product datasheet
Technical data
Electrical data
__
Nominal voltage
220…240 V
Input voltage AC
170…264 V 1)
Nominal current
0.30 A 2)
Mains frequency
50…60 Hz
Nominal input voltage (SD port)
220…240 V 3)
Power factor λ
0.95/0.90
Total harmonic distortion
10 %
Device power loss
7.4 W 5)
Inrush current
53 A 6)
Max. ECG no. on circuit breaker 10 A (B)
7
Max. ECG no. on circuit breaker 16 A (B)
12
7)
Max. ECG no. on circuit breaker 25 A (B)
20
7)
Max. no. of ECGs on 16A MCB with EBN-OS
30
Surge capability (L/N-Ground)
8 kV 8)
Surge capability (L-N)
6 kV 9)
Surge capability (L/N – SD)
6 kV 9)
Surge capability (SD – Ground)
8 kV 8)
Nominal output power
60 W 10)
ECG efficiency
90.5 % 11)
Nominal output voltage
30…115 V 12)
U-OUT (working voltage)
120 V
Nominal output current
350…1050 mA
Output current tolerance
±3 %
Output ripple current (100 Hz)
15 %
Minimum output current
70 mA 13)
Galvanic isolation
SELV
4)
7)
1) Permitted voltage range
2) At 230 V
3) In relation to N / Active: input current > 2.0 mA
pk
4) Minimum/Full load at 230 V/Half load at 230 V
/ Inactive: input currrent < 0.5 mA
pk
/ Suitable for three phase System only for 220…240 V
AC
5) Maximum
6) t
width
7) Type B
= 200 µs (measured at 50 % I
)
peak
8) EQUI @ 12 Ohm acc. to EN 61547
9) @ 2 Ohm, acc. to EN61547
10) Partial load 11…60 W / Not dimmed
11) At full load and 230 V
12) 35…115 V for output current >700 mA
June 17, 2016, 11:43:50
OT 60/170…240/1A0 4DIMLT2 E
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 6
Product datasheet
13) Physical Minimum Dimming Current 70 mA
Dimensions & weight
__
Length
133.0 mm
Width
77.0 mm
Height
40.0 mm
Mounting hole spacing, length
122.5 mm
Mounting hole spacing, width
-
Product weight
280.00 g
Cable cross-section, input side
0.25…2.5 mm² 1)
Cable cross-section, output side
0.2…1.5 mm² 2)
Wire preparation length, input side
10…11 mm 3)
1) Flexible / Solid leads / Equipotential pole only 0.2…1.5 mm²
2) Flexible / Solid leads
3) Equipotential pole 8.5…9.5
Temperatures & operating conditions
Ambient temperature range
-40…+60 °C 1)
Maximum temperature at tc test point
85 °C 2)
Max.housing temperature in case of fault
120 °C
Permitted rel. humidity during operation
5…85 %
1) T (max) = 60°C I
≤ 700mA, T (max) = 55°C I >700mA
a
out
a
out
2) Maximum at the Tc-point
Lifespan
ECG lifetime
1) At T
case
85000 h 1)
= 75°C at T point / 10% failure rate
c
June 17, 2016, 11:43:50
OT 60/170…240/1A0 4DIMLT2 E
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 6
Product datasheet
Expected Lifetime
Product name
OT 60/170…240/1A0
4DIMLT2 E
ECG ambient temperature [ta]
60
50
47
Temperature at tc-point [°C]
85
75
72
1)
1)
100000 1)
Lifetime [h]
50000
85000
1) Max. 10% failure rate at tc max and input voltage 230 V
AC
Capabilities
__
Dimmable
Yes
Dimming interface
4DIM / DALI / StepDIM / AstroDIM / MainsDIM
Dimming range
10…100 % 1)
Suitable for fixtures with prot. class
I / II
Constant lumen function
Programmable
NTC input
Yes
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Max. cable length to lamp/LED module
2.0 m
2)
1) For ≥700mA nominal output current
2) Supports 15K, 5 %, NCP18XW153J03RB / Supports 15K, 3 %, NCP15XW153E03RC + 390 Ohm / Supports 10K, 5 %, NCP18XH103J03RB / EPCOS
B57423V2473H
Certificates & standards
1)
Type of protection
IP20
Standards
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN
62384/Acc. to EN 55015:2006 + A1:2007 +
A2:2009/Acc. to EN 61547/Acc. to IEC 61000-3-2/Acc.
to IEC 61000-3-3/Acc. to IEC 62386-101/Acc. to IEC
62386-102/Acc. to IEC 62386-207
Approval marks – approval
CE / ENEC 10 / VDE / VDE-EMC / CQC (in preparation)
1) IP Fixture rating > IP54
Logistical data
Temperature range at storage
June 17, 2016, 11:43:50
OT 60/170…240/1A0 4DIMLT2 E
-25…80 °C
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 6
Product datasheet
Wiring Diagram
Wiring diagram
__
Wiring diagram
Equipment / Accessories
_ DALI magic hardware for configuring 4DIM ECGs necessary
_ Programmable via Tuner4TRONIC software
Additional product information
_ Default output current is 700 mA without any resistor connected to the LEDset port. As soon as the driver detects one time a
resistor value within the resistor range of 2.37 kOhm (1050 mA) and 24.9 kOhm (200 mA) for more than 3 s, the driver
activates the LEDset2 mode.
_ The driver withstands an input voltage of up to 350 Vac for a maximum of two hours. Shut down of output load might occur in
case the supply voltage exceeds the declared input voltage range.
_ Shut down of output load happens if the input voltage of the load is below the allowed minimum output voltage of the driver.
The driver automatically tries to switch on the load cyclically.
_ In case the input voltage of the load exceeds the output voltage range of the driver, it automatically reduces the output
current to keep the output voltage controlled to the maximum allowed output voltage.
_ The driver automatically reduces the output current in case the maximum allowed output power is exceeded.
_ The driver automatically adjusts the output voltage to the maximum output voltage if no load is connected and switches off
the load after some seconds. Hot-plug of the load or external switching on the secondary side is not allowed.
_ The driver is protected against temporary overheating by automatic reduction of the output current down to 30 % and then
switches off.
_ The EQUI pin shall be connected to the heat sink of the LED module to improve the surge withstand capability of the system
and EMI in critical luminaires.
_ Several external NTCs are supported for temperature protection of the LED module or luminaire. The type of NTC can be
selected in the programming software in the temperature based mode. By default the resistor based mode is actived with
following values: start derating: 6.3 kOhm, end derating 5.0 kOhm, shut off: 4.3 kOhm, derating level 50 %.
June 17, 2016, 11:43:50
OT 60/170…240/1A0 4DIMLT2 E
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 6
Product datasheet
_ The default dimming mode is StepDIM / AstroDIM / DALI (wiring selection) with following values for:- StepDIM: 100 % on, 50
% dimming level if SD port is active, fade time 180 s- AstroDIM: 100 % on, 50 % dimming level, 6 h dimming duration, start of
dimming duration 2 h before the middle of the average switched-on time, fade time 180 s
_ The constant lumen feature is disabled by default.
_ For MainsDIM dimming mode and for 170 Vac input voltage condition the output power should not exceed 85 % of the
maximum declared output power.
_ For input voltage of 170…190 Vac, the maximum allowed output power is linear limited starting from 100 % at 190 Vac down
to 85 % at 170 Vac, except for the 40 W type.
_ If any output level is below the physical min level, the physical min level will be used.
_ In case the 3DIM and 4DIMLT2 devices are operated on one common control phase connected to SD input the 3DIM devices
needs to have a relay as described in the 3DIM application guide.
_ The SD port is suitable for three phase systems with 220…240 Vac, for other input voltages only single phase systems are
supported.
_ For further details please consult the 4DIMLT2 application guide.
Download Data
File
Brochures
Technical Application Guide 4DIMLT2 LED drivers (GB)
Brochures
Overvoltage protection for LED street lighting (EN)
Declarations of conformity
Synergrid Conformity 4DIMLT2
__
Declarations of conformity
EMC Certificate
Declarations of conformity
ENEC certificate
Declarations of conformity
Declaration of Conformity OT 4 DIM LT2 E
Logistical Data
Product code
Product description
Packaging unit (Pieces/Unit)
Dimensions (length x width x
height)
Volume
Gross weight
4052899925199
OT 60/170…240/1A0
4DIMLT2 E
Shipping carton box
20
495 mm x 330 mm x 140 mm
22.87 dm³
6478.00 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
June 17, 2016, 11:43:50