Family data sheet

Product family datasheet
Halogen lamps, current-controlled, single-ended
Areas of application
_ Airfield lighting
__
Product benefits
_ Reduced operation and maintenance costs due to long lifetime
_ Instant and constant light output over the lamp life
_ Flicker-free operation
_ Mercury-free
Product features
_ Dimmable
_ Infrared radiation output that provides light in the worst of conditions
June 3, 2016, 18:54:18
Halogen lamps, current-controlled, single-ended
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 4
Product family datasheet
Product line drawing
Product line drawing
__
June 3, 2016, 18:54:18
Halogen lamps, current-controlled, single-ended
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 4
Product family datasheet
Technical data
Electrical data
Photomet
rical data
Dimensions & weight
Lifespan
Additional
product data
Capabilities
Product description
Nominal
wattage
Lamp current
Nominal
luminous
flux
Diameter
Length
Light
center
length
(LCL)
Lifespan
Base
(standard
designation)
Burning position
64322
30.00 W
6.6 A
400 lm
13.5 mm
44.5 mm
25.4 mm
1500 h
GY9.5
s90
64311
36.00 W
6.0 A
11.0 mm
47.0 mm
33.0 mm
1500 h
G6.35
s90
64321
45.00 W
6.6 A
900 lm
11.5 mm
47.0 mm
33.0 mm
1500 h
G6.35
s90
64320
45.00 W
6.6 A
875 lm
11.5 mm
44.5 mm
25.4 mm
1500 h
GZ9.5
s90
64346
100.00 W
6.6 A
13.5 mm
47.0 mm
33.0 mm
1200 h
G6.35
s90
64386
200.00 W
6.6 A
13.5 mm
47.0 mm
33.0 mm
1500 h
G6.35
s90
58750
200.00 W
6.6 A
13.0 mm
65.0 mm
39.1 mm
1300 h
GY9.5
Any
64354
150.00 W
6.6 A
13.5 mm
65.0 mm
39.1 mm
1500 h
GY9.5
s90
4700 lm
1)
__
Country specific categorizations
Product description
ANSI code
64322
EXL
64311
J1/59
64321
64320
LIF
J1/57
EXM
64346
J1/58
64386
J1/39
58750
EZL
64354
EWR
1) Despite transverse filament, can be inclined at any angle in s90 position
June 3, 2016, 18:54:18
Halogen lamps, current-controlled, single-ended
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 4
Product family datasheet
Safety advice
To prevent personal injury or damage to property, halogen lamps may only be operated in suitable luminaires designed with
suitable mechanisms (protective shields, grids, etc.) to ensure that in the event of a lamp bursting no parts/shards can escape
and that during operation no ultraviolet radiation can escape. There must also be a warning sign to indicate that the lamps
give off high levels of heat. Detailed information is available on request.
Application advice
For more detailed application information and graphics please see product datasheet.
References / Links
For more information on airfield lamps see the brochure:
"The reliable guiding stars - Effective solutions for airfield lighting: Tungsten halogen lamps and LED light sources".
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
June 3, 2016, 18:54:18
Halogen lamps, current-controlled, single-ended
© 2016, OSRAM GmbH. All rights reserved.