Family data sheet

Product family datasheet
SIRIUS
Low-voltage halogen lamps with dichroic reflector, road traffic
Areas of application
_ Road and rail traffic signals
__
Product benefits
_ Fixed adjustment of halogen tube to reflector provides high luminous intensity
_ Nearly constant luminous intensity due to high quality reflector coating
_ Very long life due to the halogen tube
Product features
_ Connecting cables equipped with contacts/insulation widely resistant to corrosion and heat
June 13, 2016, 16:13:12
SIRIUS
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 4
Product family datasheet
Product line drawing
Product line drawing
__
June 13, 2016, 16:13:12
SIRIUS
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 4
Product family datasheet
Technical data
Electrical data
Product description
Nominal
wattage
Nominal
voltage
Test voltage
SIG 64002
20.00 W
12.0 V
12 V
SIG 64002/B
__
1)
Nominal
current
1.67 A
Lamp current
1.67 A
Photomet
rical data
Light technical data
Nominal
luminous
flux
Aperture window,
maximum
120 lm
10.2 mm
Dimensions
& weight
Focal
length
Diameter
51.0 mm
20.00 W
12.0 V
12 V
SIG 64004
50.00 W
10.0 V
10 V
120 lm
350 lm
10.2 mm
42.0 mm
51.0 mm
51.0 mm
SIG 64005
50.00 W
10.0 V
10 V
250 lm
10.2 mm
42.0 mm
51.0 mm
Lifespan
Capabilities
Country specific
categorizations
Product description
Base diameter
Overall length
Nominal lamp
life time
Burning position
Order reference
SIG 64002
24.5 mm
46.5 mm
2000 h 2)
p90
SIG 64002 CL 20
24.5 mm
46.5 mm
2000 h
2)
p90
SIG 64002/B CL
24.5 mm
46.5 mm
2000 h 2)
p90
SIG 64004 CL 50
46.5 mm
2)
p90
SIG 64005 FL CL
SIG 64002/B
1)
SIG 64004
SIG 64005
24.5 mm
6000 h
1) For rail signals
2) Average lifespan at test voltage/current
June 13, 2016, 16:13:12
SIRIUS
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 4
Product family datasheet
Safety advice
All halogen signal lamps operate at high temperature and pressure. They may therefore only be operated in signal
equipment/luminaires specially designed for the purpose. Make sure that the lamps are protected against moisture during
operation and in particular during relamping.
Application advice
For more detailed application information and graphics please see product datasheet.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
June 13, 2016, 16:13:12
SIRIUS
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 4