Family data sheet

Product family datasheet
High-voltage krypton lamps, road traffic
Areas of application
_ Road traffic signalling systems
__
Product benefits
_ Excellent optical efficiency thanks to a small cradle diameter
_ High luminous efficacy from krypton as filler gas
_ Max. premature failure rate: 2 % up to 3,000 h (related to lamp failures only)
_ High resistance to shock and vibration thanks to nine supports for the filament
Product features
_ Lamp base resistant to corrosion
_ Long average lamp lifetime: 8,000 h
_ Maintenance intervals up to four months possible (depending on installation)
June 23, 2016, 08:35:44
High-voltage krypton lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 4
Product family datasheet
Product line drawing
__
June 23, 2016, 08:35:44
High-voltage krypton lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 4
Product family datasheet
Technical data
Electrical data
Photomet
rical data
Dimensions & weight
Capabilities
Product description
Nominal
wattage
Nominal
voltage
Test voltage
Nominal
luminous
flux
Diameter
Overall length
Light
center
length
(LCL)
Burning position
SIG 1541
60.00 W
230…240 V
235 V
380 lm
62.0 mm
91.0 mm
69.0 mm 1)
s105
2)
SIG 1543
75.00 W
230…240 V
235 V
520 lm
62.0 mm
91.0 mm
69.0 mm 1)
s105
2)
1)
s105
2)
SIG 1546
100.00 W
230…240 V
235 V
830 lm
62.0 mm
101.0 mm
79.0 mm
Country specific
categorizations
__
Product description
Order reference
SIG 1541
SIG 1541 CL 60W
SIG 1543
SIG 1543 CL 75W
SIG 1546
SIG 1546 CL 100
1) Distance from the coil to the top of base
2) Only the permissible burning position may be used otherwise the lamp will fail prematurely
June 23, 2016, 08:35:44
High-voltage krypton lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 4
Product family datasheet
Safety advice
Use only in signal equipment/luminaires that are specially designed for the purpose.
Protect the lamps against moisture during operation and installation.
Application advice
For more detailed application information and graphics please see product datasheet.
Legal advice
Correspond to DIN 49842 part 1 and 3
Meet luminous intensity requirements of DIN 67527-1/EN 12368 (depending on installation)
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
June 23, 2016, 08:35:44
High-voltage krypton lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 4