Family data sheet

Product family datasheet
Standard high-voltage longlife lamps, road traffic
Areas of application
_ Road traffic signalling systems
__
May 25, 2016, 17:21:50
Standard high-voltage longlife lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 4
Product family datasheet
Product line drawing
__
May 25, 2016, 17:21:50
Standard high-voltage longlife lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 4
Product family datasheet
Technical data
Electrical data
Photomet
rical data
Dimensions & weight
Capabilities
Product description
Nominal
wattage
Nominal
voltage
Test voltage
Nominal
luminous
flux
Diameter
Overall length
Light
center
length
(LCL)
Burning position
SIG 1534 LL 1)
40.00 W
235 V
235 V
200 lm
62.0 mm
107.0 mm
69.0 mm 2)
s135
3)
Country specific
categorizations
Product description
SIG 1534 LL
1)
Order reference
SIG 1534 LL CL
1) Not for new designs
__
2) Distance from the coil to the top of base
3) Only the permissible burning position may be used otherwise the lamp will fail prematurely
May 25, 2016, 17:21:50
Standard high-voltage longlife lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 4
Product family datasheet
Safety advice
Use only in signal equipment/luminaires that are specially designed for the purpose.
Protect the lamps against moisture during operation and installation.
Application advice
For more detailed application information and graphics please see product datasheet.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
May 25, 2016, 17:21:50
Standard high-voltage longlife lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 4