PhMKDg..., Triangular, LVAC www.vishay.com Vishay ESTA ESTAdry D-Type, LVAC Power Capacitors FEATURES • Self-healing technology • Over pressure tear-off fuse • Smallest available height for 50 kvar units: 210 mm (+ 68 mm for terminals) • Excellent heat dissipation • Screw-on terminal with M10 bolts • Resin filling provides thermal conductivity similar to that of oil-filled capacitors • Aluminum case is welded and hermetically sealed • No paint required for OUTDOOR applications • UL and cUL approved APPLICATIONS • Areas with dust and moisture, which require a high degree of protection and high creepage distances. Also for OUTDOOR applications • Free-standing, fixed individual PFC (e.g. motors, lighting, transformers) • Automatic central PFC (e.g. group of loads) • Harmonic trap (e.g. UPS, frequency drives, converter) • Pole-mounted PFC QUICK REFERENCE DATA Series PhMKDg…, triangular PhMKDgF…, triangular ESTAdry D-type, LVAC power capacitors dry - INDOOR, IP00 ESTAdry D-type, LVAC power capacitors dry - OUTDOOR, IP00 Capacitors, fixed, low voltage Capacitors, fixed, low voltage MKP, metallized polypropylene film MKP, metallized polypropylene film 1000 1000 Capacitance min. (μF) 3-phase D: 3 x 115.5, 3-phase Y: 3 x 140.1 3-phase D: 3 x 115.5, 3-phase Y: 3 x 140.1 Capacitance max. (μF) 3-phase D: 3 x 331.6, 3-phase Y: 3 x 334.3 3-phase D: 3 x 331.6, 3-phase Y: 3 x 334.3 Output min. (kvar) 30 30 Output max. (kvar) 56.2 56.2 Description Type Technology Voltage max. (V) Revision: 04-Feb-16 Document Number: 13007 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PhMKDg..., Triangular, LVAC www.vishay.com CAPACITORS IN TRAINGULAR CASING Vishay ESTA 3-PHASE CAPACITOR, INDOOR DESCRIPTION The PhMKDg series capacitor in a triangular aluminum case with a standard rating of 50 kvar, augments Vishay ESTA broad line of reliable three-phase power capacitors. The PhMKDg series is preceded by our PhMKP and the ESTAdry PhMKPg series in aluminum tubular casings, with outputs up to 37 kvar, depending on their rated voltage. The standard PhMKDg series capacitor is designed for indoor application, with externally arranged discharge resistors (U 50 V/60 s). For outdoor application, the discharge resistors can be incorporated internally (U 75 V/180 s). Also, the pure aluminum welded cases render these capacitors perfectly suitable for outdoor use. The PhMKDg capacitor can be used for both controlled equipment and for stationary or mobile fixed compensation, e.g. for induction-motor-operated conveyor belts in the mining industry. The indoor capacitor can be supplied with the option of a small protective cover for each individual connection or with an IP53-type overall protective cover. The triangular case and corresponding triangular arrangement of the winding elements allows for simple connection in parallel of several units (IN-LINE). The joint insulation created by means of a solid ceramic terminal base with high surface-creepage resistance and very long tracking paths establishes an additionally superior mechanical stability for the three solid connector bolts. With a resin filled pure aluminum case offering superior mechanical stability, low profile design, excellent thermal conductance, easy paralleling and a complete three-phase tear-off fuse system incorporated into the PhMKDg design, this series is the ideal first choice for new designs and applicable retrofit requirements. Revision: 04-Feb-16 Single bolt protection IP53 3-PHASE CAPACITOR, OUTDOOR Document Number: 13007 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PhMKDg..., Triangular, LVAC www.vishay.com Vishay ESTA ESTAdry D-TYPE PhMKDg, INDOOR TECHNICAL DATA STANDARDS IEC 60831-1 + 2, EN 60831-1 + 2, UL810 LATEST EDITION UL / ULC FILE # E97723 Overvoltages (in accordance with the above standards) Ucn + 10 % (up to 8 h daily) Ucn + 15 % (up to 30 min daily) Ucn + 20 % (up to 5 min, only 200 times in the life of the capacitor) Ucn + 30 % (up to 1 min, only 200 times in the life of the capacitor) Please also refer to “Terms and Definitions”. Overcurrent (in accordance with the above standards) 1.3 x In, 1.43 x In with 10 % overvoltages, 10 % over capacitance and harmonics included, continuous operation Please also refer to “Terms and Definitions”. Tolerance on capacitance - 5 % / + 10 % in accordance with the standards ± 5 % as Vishay ESTA standard Test voltage, terminal / terminal 2.15 x Ucn, VAC, 2 s (routine test) Test voltage, terminal / casing 6000 VAC, 2 s (routine test) Inrush current 300 times rated current In Losses 0.4 W/kvar to 0.5 W/kvar (without discharge resistors) Statistical life expectancy (2) > 130 000 operating h (ESTAdry) Degree of protection IP00 (terminal cover for higher protection class upon request), indoor Ambient temperature category -25 / D (max. 55 °C), (-40 / D on request) Permitted casing temperature Max. 65 °C (measured on top of the can) Cooling Naturally air-cooled Permissible relative humidity Maximum 95 % Maximum allowed altitude 2000 m above sea level Mounting position Vertical and horizontal Mounting and grounding Threaded M12 stud at the bottom of the container Safety features All-phase overpressure tear-off fuse, self-healing Casing Aluminum can, welded top Dielectric Polypropylene film, self-healing Filling agent Resin-filled (ESTAdry), non-PCB, non-toxic Terminals Threaded studs M10 3-PHASE CAPACITORS IN TRAINGULAR CASING, INDOOR ARTICLE NO. (1) RATED VOLTAGE V RATED OUTPUT kvar CAPACITANCE μF CURRENT A (50 Hz) WEIGHT kg HEIGHT H mm PhMKDg400.3.50,00-K 5345-44814-xx 400 50 3 x 331.6 72.2 4.0 210 PhMKDg440.3.50,00-K 5345-44804-xx 440 50 3 x 274.0 65.6 4.0 210 PhMKDg440.3.56,20-K 5345-44805-xx 440 / 415 56.2 / 50 3 x 308.0 73.7 / 69.6 4.0 210 PhMKDg460.3.50,00-K 5345-44803-xx 460 50 3 x 250.7 62.8 4.0 210 PhMKDg525.3.50,00-K 5345-44824-xx 525 50 3 x 192.5 55.0 4.0 210 PhMKDg690.2.50,00-K 5345-44807-xx 690 50 3 x 334.3 Y 41.8 4.0 210 PhMKDg760.2.50,00-K 5345-44808-xx 760 50 3 x 275.5 Y 38.0 4.0 210 TYPE ORDERING INFORMATION Packing units 1 piece per carton Notes • Other voltage ratings, outputs, and frequencies on request. (1) Version no. xx may differ as it respects small changes, e.g. on the label (2) Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of quality or durability. Revision: 04-Feb-16 Document Number: 13007 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PhMKDg..., Triangular, LVAC www.vishay.com Vishay ESTA DIMENSIONS, INDOOR M10 Screw bolt M10 brass blank Hexagonal nut M10 DIN 934 steel hot dip galvaniced Spring washer wave B10 DIN 137 steel hot dip galvaniced Hexagonal nut M10 DIN 934 steel hot dip galvaniced Hexagon thin nut M10 DIN 439 A2 35 + 1 51 ± 2 68 ± 2 25 Required space for bulging 15.8 + 1 H±1 Screw bolt M8x15 steel hot dip galvaniced Toothed lock washer Hexagonal nut M12 M12 172 78 160 70 Drawing 6 DISCHARGE RESISTORS Δ Y RECOMMENDED TORQUES STYLE RECOMMENDED TORQUE Terminals M8 6 Nm Terminals M10 (new K-type PhMKDg...-K) 20 Nm M12 mounting stud 10 Nm Revision: 04-Feb-16 Document Number: 13007 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PhMKDg..., Triangular, LVAC www.vishay.com Vishay ESTA ESTAdry D-TYPE PhMKDgF, LVAC POWER CAPACITORS, OUTDOOR TECHNICAL DATA STANDARDS Overvoltages (in accordance with the above standards) Overcurrent (in accordance with the above standards) Tolerance on capacitance Test voltage, terminal / terminal Test voltage, terminal / casing Inrush current Losses Statistical life expectancy (1) Degree of protection Ambient temperature category Permitted casing temperature Cooling Permissible relative humidity Maximum allowed altitude Mounting position Mounting and grounding Safety features Casing Dielectric Filling agent Terminals IEC 60831-1 + 2, EN 60831-1 + 2, LATEST EDITION Ucn + 10 % (up to 8 h daily) Ucn + 15 % (up to 30 min daily) Ucn + 20 % (up to 5 min, only 200 times in the life of the capacitor) Ucn + 30 % (up to 1 min, only 200 times in the life of the capacitor) Please also refer to “Terms and Definitions”. 1.3 x In, 1.43 x In with 10 % overvoltages, 10 % over capacitance and harmonics included, continuous operation Please also refer to “Terms and Definitions”. - 5 % / + 10 % in accordance with the standards ± 5 % as Vishay ESTA standard 2.15 x Ucn, VAC, 2 s (routine test) 6000 VAC, 2 s (routine test) 300 times rated current In 0.4 W/kvar to 0.5 W/kvar (without discharge resistors) > 130 000 operating h (ESTAdry) IP00 outdoor -25 / D (max. 55 °C), (-40 / D on request) Max. 65 °C (measured on top of the can) Naturally air-cooled Maximum 95 % 2000 m above sea level Vertical and horizontal Threaded M12 stud at the bottom of the container All-phase overpressure tear-off fuse, self-healing Aluminum can, welded top Polypropylene film, self-healing Resin-filled (ESTAdry), non-PCB, non-toxic Threaded studs M10 Available types same as for indoor use, different type designation “F”. For example: TYPE PhMKDgF460.3.50 RATED VOLTAGE V RATED OUTPUT kvar CAPACITANCE μF 460 50 3 x 250.7 CURRENT A (50 Hz) 62.8 WEIGHT kg 4.0 HEIGHT H mm 210 ORDERING INFORMATION Packing units 1 piece per carton RECOMMENDED TORQUES STYLE Terminals M8 Terminals M10 M12 mounting stud RECOMMENDED TORQUE 6 Nm 10 Nm 10 Nm Notes • Other voltage ratings, output, and frequencies upon request (1) Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of quality or durability. Revision: 04-Feb-16 Document Number: 13007 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PhMKDg..., Triangular, LVAC www.vishay.com Vishay ESTA +1 DIMENSIONS, OUTDOOR Hexagonal nut M12 Toothed lock washer +2 44 - 2 +2 68 - 2 H ±1 15.8 M12 Screw bolt M8 X 10 Slotted nut M10 Spring washer wave Hexagonal-nut M10 Screw bolt M10 M10 X 172 70 78 160 X: Drawing 7 ACCESSORIES: SUPPORT FOR POLE AND WALL MOUNTING A-A 200 A M16 A Revision: 04-Feb-16 Document Number: 13007 6 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000