d c60

Panel Mount
Datasheet
DC60 Series
• Ratings from 3A to 7A @ 60 VDC
• Bi-polar transistor output
• UL Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC and DC control
• Epoxy Free Design
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage
3.5-32 VDC
90-280 VAC/VDC
3A
5A
7A
DC60S3
DC60SA3
DC60S5
DC60SA5
DC60S7
DC60SA7
AVAILABLE OPTIONS
Series
DC60
*
Required for valid part number
For options only and not required for valid part number
Not all part number conbinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
Termination
Blank: Screws & clamps
K: Installed standoffs with Output Type
screws for PC Board
Blank: Normally Open
mounting (1)
-B: Normally Closed (for DC control only)
Control Voltage
S: 3.5-32 VDC
SA: 90-280 VAC/DC
SA
3
K
H
Rated Load Current
3: 3 Amps
5: 5 Amps
7: 7 Amps
-B
Thermal Pad
Blank: Not Included
H: Included
OUTPUT SPECIFICATIONS (2)
Description
Recommeded Operating Voltage [Vdc]
Absolute Maximum Rating [Vdc]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum Load Current [Adc] (3)
Minimum Load Current [mA]
Maximum Surge Current (10 msec)[Adc]
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Minimum heat sink @ Ambient (for max current= °C/W & Ta)
3A
5A
7A
3-48
60
0.1
3
20
6
1
2
5 @ 60°C
3-48
60
0.1
5
20
10
1.2
2
5 @ 60°C
3-48
60
0.1
7
20
14
1.3
2
5 @ 40°C
INPUT SPECIFICATIONS (2)
Description
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage (4)
Must Turn-Off Voltage (5)
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impedance [Ohms]
Maximum Turn-On Time [msec] (6)
Maximum Turn-Off Time [msec] (7)
Do not forget to visit us at: www.crydom.com
DC Control
AC Control
3.5-32 VDC
-32 VDC
3.5 VDC
1 VDC
2.2 mA
25 mA
1500
0.1
0.3
90-280 VAC/VDC
90 VAC/VDC
10 VAC/VDC
2 mA
5.5 mA
60K
10
40
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
GENERAL SPECIFICATIONS (2)
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
Baseplate Material
Input Terminal Screw Torque Range (in-lb/Nm)
Load Terminal Screw Torque Range (in-lb/Nm)
SSR Mounting Screw Torque Range (in-lb/Nm)
Input/Load Terminal Screw Torque Range (in-lb/Nm) (1)
Humidity
MTBF (Mean Time Between Failures) at 40°C ambient temperature (8)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (8)
4000 Vrms
109 Ohm
8 pF
-30 to 80°C
-40 to 125 °C
2.46 oz (70 g)
UL94 V-0
Aluminum
13-15 /1.5-1.7
18-20 / 2-2.2
18-20 / 2-2.2
w/”K” option 8-10 / 0.9-1.13
85% non-condensing
21,395,130 hours (2,441 years)
11,545,504 hours (1,317 years)
WIRING DIAGRAM
* Inductive loads must be diode suppresed.
+
+
-
Load
V
+
* Load
*
V
-
+
Recommended Wire Sizes
Wire Size
(Solid / Stranded)
Terminals
+1
2
OUTPUT
+1
S O L I D S TAT E R E L AY
S O L I D S TAT E R E L AY
4
4
+3
INPUT
Input
2
OUTPUT
24 AWG (0.2 mm2) / 0.2 [minimum]
10 [44.5]
2 x 12 AWG (3.3 mm2) / 3.3 [maximum]
90 [400]
20 AWG (0.5
+3
INPUT
Output
2 x 8 AWG (8.4 mm2) / 8.4 [maximum]
90 [400]
INPUT
3
1 +DC
Control
Circuit
Trigger
Circuit
4
Input Current (mA)
25
2
4
Converter
10
5
0
5
10
-DC
15
20
25
30
35
Input Current vs Input Voltage
Standard Regulated AC Input
5
4.5
1 +DC
AC/DC
15
DC Input Voltage
Trigger
Circuit
2
-DC
Input Current (mA)
INPUT
3
20
0
DC60 Series AC Control
AC/DC
30 [133]
110 [490]
Input Current vs Input Voltage
Standard Regulated DC Input
DC60 Series DC Control
AC/DC
/ 0.518 [minimum]
2 x 10 AWG (5.3 mm2) / 5.3
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
-DC
mm2)
+
V
-
+
V
-
+DC
Wire Pull-Out
Strength (lb)[N]
4
3.5
3
2.5
2
1.5
1
0.5
0
0
50
100
150
AC Input Voltage
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
200
250
300
Panel Mount
Datasheet
MECHANICAL SPECIFICATIONS (1)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Screw Termination
1.1
[27.9]
0.49
[12.4]
+1
1.88
[47.6]
OUTPUT
INPUT
1.1
[27.9]
0.49
[12.4]
0.89
[22.6]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
2
+1
1.7
[43.2]
S O L I D S TAT E R E L AY
4
Hex Standoff Termination (“K” Option) (1)
2.25
[57.3]
1.88
[47.6]
+3
OUTPUT
Mounting
Hole/Slot
0.19 [4.9]
DIA.
2
INPUT
1.0
[25.4]
1.0
[25.4]
1.75
[44.5]
1.75
[44.5]
+3
GENERAL NOTES
(1) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm).
(2) All parameters at 25°C unless otherwise specified.
(3) Heat sinking required, see derating curves.
(4) Maximum turn-on voltage for -B, DC control is 1VDC.
(5) Must turn-off voltage for -B, DC control is 3.5VDC.
(6) Turn-on time for -B version is 300µsec.
(7) Turn-off time for -B version is 100µsec.
(8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(9) For single surge pulse Tc=25°C; Tj=150°C.
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
2.25
[57.3]
1.7
[43.2]
S O L I D S TAT E R E L AY
4
1.04
[26.4]
(2 places)
0.93
[23.6]
(4 places)
1.0
[25.4]
(2 places)
Panel Mount
Datasheet
SURGE CURRENT INFORMATION
DC60Sx3
15
10
5
0
0.1
1
10
100
15
10
5
0
1000
Surge Duration (msec)
0.1
1
10
Surge Duration (msec)
100
1000
DC60Sx7
20
Surge Current (Amp)
DC60Sx5
20
Surge Current (Amp)
20
Surge Current (Amp)
Single Pulse (9)
15
10
5
0
0.1
1
10
Surge Duration (msec)
100
1000
THERMAL DERATE INFORMATION
(i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air.
DC60Sx3
5°C/W
DC60Sx5
5°C/W
No Heat Sink(i)
Load Current (Amps)
Load Current (Amps)
2.5
2
1.5
1
0.5
0
No Heat Sink(i)
5
3
20
30
40
50
60
70
4
3
2
1
0
80
20
30
Ambient Temperature (ºC)
40
50
60
Ambient Temperature (ºC)
DC60Sx7
5°C/W
No Heat Sink(i)
Load Current (Amps)
7
6
5
4
3
2
1
0
20
30
40
50
60
Ambient Temperature (ºC)
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
70
80
70
80
Panel Mount
Datasheet
AGENCY APPROVALS
EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
E116950
ACCESORIES
Recommended Accessories
New Accessories!
Protective Cover & Hardware Kits
Protective Cover
Part number: KS101
Clear plastic cover compatible with all new
S1 designs. Safety covers provide added
protection from electric shock when
installing or checking equipment.
Cover
Hardware
Kit
KS101
HK1
HS501DR
5.0
TRM1
HSP-1
HK4
HS301 / HS301DR
3.0
TRM6
HSP-2
HS251
2.5
HS201 / HS201DR
2.0
HS202 / HS202DR
2.0
HS172
1.7
HS151 / HS151DR
1.5
HS122 / HS122DR
1.2
HS103 / HS103DR
1.0
HS101
1.0
HS073
0.7
HS072
0.7
HS053
0.5
HS033
0.36
HS023
0.25
Hardware Kit
Part number: HK4
Bag with 2 square brass accessories and 2
screw 8-32 x 5/8 for output. Used to mount
TMR1 lug terminals.
Heat Sink
Part No.
Thermal Resistance Lug Terminal Thermal Pad
[ºC/W]
Rev. 060216
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
• Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
存在电击、
爆炸或电弧
闪烁危险
•
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
Failure to follow these instructions can result in des lésions corporelles graves ou des
serious injury, or equipment damage.
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
材料损坏和高温外壳的危险性
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
Panel Mount
Datasheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
铅
汞
镉
有毒有害物质或元素
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr (VI))
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
(PBB)
多溴二苯醚
(PBDE)