pdf

www.osram.com
LED STAR PAR16 35 36° 827 GU10
Product description
Product Offering
Type reference
Wattage
CCT
PAR16 35 36°
4,4W
2700K
lm
CRI
230lm
>80
• Compact mains voltage LED reflector lamp in PAR16
shape
• GU10 base for easy replacement
• Equipped with high-efficiency patented LEDs, quality
assured
• Shockproof and vibration-proof
1. Key Features and Benefits
• LED PAR16 lamp as replacement for Halopar 35W lamp
• Voltage: 100 – 240V
• GU10 base
• Warm white color (2700K)
• conform to 1194/2012 EU
• reduces energy consumption > 85%
• Energy Class A+
• shock-proof and vibration-proof
• 15.000 hours lifetime
• Non dimmable1
• UV and NIR radiation free
• Mercury free
• 3 years Osram Guarantee2
1
2
See www.osram.com/dim
See www.osram.com/guarantee
Edition May 2013
subject to alteration
1
3
2. Common Characteristics
Average lifetime4
Switching cycles
Casing material
Starting time
(30s on, 30s off)
15,000h
>100,000
plastic
Mercury
max.
Base Type
Length
Diameter
0.0mg
GU10
53mm
50mm
3. Characteristic Range
Type reference
68g
<0.5s
Tc temperature
max.5
70°C
Power factor
<1s
0.42
Nominal current
(110-230V/50Hz)
Max 69mA
Beam angle
36°
3
Wattage
Luminous
flux
PAR16 35 36°
Weight
Warm up time
for 60% light
4,4W
230lm
Luminous
intensity
650cd
Correlated colour
temperature
2700
SDCM
CRI
>6
>80
4. Mounting information
Tc
3
Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical
values given above for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of an
individual product; individual products may vary from the typical values.
4
The average lifetime of LED lamps is defined as the number of hours when the light output of 50% of a large group of identical lamps goes below 70% of its
initial luminous flux (L70B50, IEC60969).The lifetime is estimated at room temperature (25°C), free air burning, base up burning position and at rated voltage.
To achieve a full lifetime a good heat exchange for the electronic components is required.
5
The Tc is defined as the highest permissible temperature which may occur on the outer surface of the LED lamp (in the indicated position) under normal
operating conditions and at the rated voltage/current/power or the maximum of the rated voltage/current/power range (DIN EN 62031: 2009-01)
5. Disposal information
WEEE-lamps can be returned at specific collection points.
LED lamps have to be disposed as special waste.
Edition May 2013
subject to alteration
2
6. Application Information
Applications
• hotels
• restaurant
• commercial areas
• residentials
• art galleries and museum
• office space
Application Notes
1. Suitable for indoor application.
2. For outdoor applications and operation
in damp locations special approved
fixture are required.
3. Input voltage: AC: 100-240V
4. Operating temperature range between
-20°C and 40°C
7. Cost savings: example
Reference product
description
Similar halogen product
Watts saved
PAR16 35
HALOPAR 35W
30,4W
Cost saved
after 2 year
Cost saved
after 5 years
9,41€
Cost saved
after 15 years
40€
98,50€
Based on the assumption of 2.7hours/day on and an energy cost of 0.21€/kWh
8. Ordering Guide
Type reference
LED STAR PAR16 35 36°
Product Number – 1pcs
Product Number – 1 shipping unit
Number of pcs / ship. unit
4052899910348
4052899910447
6
9. Lamp conformity
2004/108/EC Electromagnetic compatibility (EMC)
2011/65/EC Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
1907/2006 Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH Regulation)
2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE)
EN 62471 Photobiological safety of lamps and lamp systems
IEC/TR 62471-2 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to
non-laser optical radiation safety
EN 55015 Limits and methods of measurement of radio disturbance
EN 61000-3-2 Electromagnetic compatibility – Limits for harmonic current emission
EN 61000-3-3 Electromagnetic compatibility – Limitation of voltage changes, voltage fluctuations, flicker in public low voltage supply
systems
EN61547 Electromagnetic compatibility immunity requirements
Edition May 2013
subject to alteration
3