pdf

www.osram.com
Product Information
LEDSTAR® CLASSIC B25 frosted & clear sparkling
Benefits
Key Features
• Replacement for 25W Incandescent lamp
• Dimension comparable Classic B Incandescent
• Good thermal management
• 4W LED lamp as high-quality replacement for a 25W
incandescent candle lamp
• Non Dimmable
• E14 base
• Available in 2700K warm white and 4000K
• 15,000 hrs
• UV and NIR radiation free
• Mercury free
Product
Wattage
CCT
lm
Base Diameter
Length
Weight
Viewing
Angle
EAN10
EAN40
(ship.unit)
Ship.
unit
LEDSTAR CLASSIC B25
Clear Sparkling
4
2700
250
E14
38 mm
105 mm
52 g
200°
40502899232631
4052899232648
10
LEDSTAR CLASSIC B25
frosted
4
2700
250
E14
38 mm
105 mm
50 g
200°
40502899232655
4052899232662
10
4
4000
250
E14
38mm
105mm
55g
200°
4052899232778
4052899232785
10
LEDSTAR CLASSIC B25
frosted
¹With many common dimmers, see also www.osram.com/dim
2
Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical values given above for the
technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of an individual product; individual products may vary
from the typical values.
3 The average lifetime of LED lamps is defined as the number of hours when the light output of 50% of a large group of identical lamps goes below 70% of its initial luminous flux
(L70B50, IEC60969).The lifetime is estimated at room temperature (25°C), free air burning, base up burning position and at rated voltage.
LEDSTAR CLASSIC B Clear Sparkling &
Frosted
BU LP PPM Led Lamps
For internal use only
1
www.osram.com
Product Information
LEDSTAR® CLASSIC B25 advanced frosted & clear sparkling
Common Characteristics3
Average lifetime4
Switching cycles
Casing material
Starting time
Warm up time for
60% light
Power factor
15,000 hrs
(30s on, 30s off)
100,000
Plastic
<0.2 s
0.0 s
0.6
Lamp Current
Irush current
Tc temperature
max.5
CRI
Mercury max.
30 mA
2A
88°C
80
0.0 mg
TC
Disposal information
• Lamps with WEEE sign can be returned at specific collection points.
• LED lamps have to be disposed as special waste.
3
Typical values. All the technical parameters apply to the entire lamp. In view of the complex manufacturing process for light emitting diodes, the typical values given above for the
technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of an individual product; individual products may vary
from the typical values.
4 The average lifetime of LED lamps is defined as the number of hours when the light output of 50% of a large group of identical lamps goes below 70% of its initial luminous flux
(L70B50, IEC60969).The lifetime is estimated at room temperature (25°C), free air burning, base up burning position and at rated voltage.
5 The Tc is defined as the highest permissible temperature which may occur on the outer surface of the LED lamp (in the indicated position) under normal operating conditions and at
the rated voltage/current/power or the maximum of the rated voltage/current/power range (DIN EN 62031: 2009-01)
LEDSTAR CLASSIC B Frosted & Clear
Sparkling
BU LP PPM Led Lamps
For internal use only
2
www.osram.com
Product Information
LEDSTAR® CLASSIC B25 advanced frosted & clear sparkling
Application information
•
•
•
•
•
Suitable for indoor application.
For outdoor applications and operation in damp locations special approved fixture are required.
Input voltage: 220-240V
Storage temperature & humidity conditions (-20°C up to +40°C, at max. 95% relative humidity)
Operating temperature & humidity conditions (-20°C up to +40°C, at max. 95% relative humidity)
Lamp conformity
•
•
•
•
•
•
•
•
•
•
•
2004/108/EC Electromagnetic compatibility (EMC)
244/2009 Ecodesign requirements for non-directional household lamps
IEC/ PAS 62612 Self ballasted LED-lamps for general lighting services – Performance requirements
2009/125/EC Ecodesign requirements for energy related products
2011/65/EC Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
1907/2006 Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH Regulation)
2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE)
EN 62471 Photobiological safety of lamps and lamp systems
EN 55015 Limits and methods of measurement of radio disturance
EN 61000-3-2 Electromagnetic compatibility – Limits for harmonic current emission
EN 61000-3-3 Electromagnetic compatibility – Limitation of voltage changes, voltage fluactuations, flicker in public low
voltage supply systems
• EN61547 Electromagnetic compatibility immunity requirements
• 1194/2012 Eco design requirement for directional lamps, light emitting diode lamps and related equipment (DIM II)
• IEC 62560 self-ballasted LED-lamps for general lighting services by voltage >50V – Safety specifications
• 874/2012/EU Energy labeling of electrical lamps and luminaires
LEDSTAR CLASSICB25 Frosted & Clear
Sparkling
BU LP PPM Led Lamps
For internal use only
3