ACmaxx GreenTech EC-compact fans - ebm

Information
DC axial fans
ACmaxx / EC fans
183
Representatives
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
184
187
188
192
194
196
200
2016-01
Technical information about ACmaxx
Overview
ACmaxx axial fans
GreenTech EC-compact fans
Energy-saving axial fans
EC axial fans
ACmaxx in-line duct fan
ACmaxx / EC fans
Technical information
about ACmaxx / GreenTech EC-compact fans
AC
Progress made by ebm-papst
The best example: The ACmaxx fans from ebm-papst, which, thanks to an
ingenious yet simple improvement over conventional AC fans, provide
substantial benefits.
The aim in developing the new ACmaxx series was to raise the technology
standard of the conventional AC fan significantly and, in the process,
facilitate the transition to the new technology by retaining the overall
mounting dimensions. In short, to ensure the fans can be replaced 1:1
without any peripheral changes or changes to the voltage situation.
ebm-papst offers two generations of ACmaxx products that meet
different needs.
2016-01
What ACmaxx and GreenTech EC-compact fan have in common:
Energy efficiency
The drive concept is based on state-of-the-art GreenTech EC technology
with outstanding motor efficiency. Compared to AC fans of the same size,
ACmaxx energy consumption is up to 77% lower–for higher cooling
capacity! Just the energy savings means that the products pay for
themselves after only a few months. The savings over the entire service
life, especially in systems with multiple fans, is considerable.
184
ACmaxx
ACi
Independent of mains frequency and mains voltage
The ACmaxx and GreenTech EC-compact fans are prepared for direct
connection to wide ranges of AC voltages and frequencies. The speed,
and thus
important properties of the fan such as air flow and noise, are
independent of the power frequency and do not change, even within
the defined voltage range. Voltage fluctuations in the power system are
automatically compensated for.
Long service life
The efficiency of ACmaxx and GreenTech EC-compact fan motors is up to
75% higher than that of conventional AC fan variants. This not only saves
energy, it also means less self-heating in the motor. The reduced
heating has a direct, positive effect on the bearing system, which is why
the fans have a service life that is up to 85% longer! This also extends
the service and maintenance intervals significantly. The expense of
replacement fans, and even more expensive downtimes, are kept to a
manageable minimum.
Information
DC centrifugal fans
DC axial fans
ACmaxx / EC fans
Technical information
about ACmaxx / GreenTech EC-compact fans
ACi
ACmaxx / EC fans
GreenTech EC-compact fan is more efficient!
ACmaxx saves energy, and the GreenTech EC-compact fan generation
saves even more. While an AC fan at 50 Hz can barely reach an overall
efficiency of 5-6%, the ACmaxx makes it to approx. 20-25%. With the new
GreenTech EC-compact fans ACi 4400, a remarkable level of up to 30% is
reached. This is the result of the optimisation of the entire package made
up of drive, electronics, AC/DC conversion and aerodynamics. Thus the
new GreenTech EC-compact fans series boasts energy savings of almost
75% compared to the corresponding AC fan, thus providing significantlyhigher savings than the 40% level of the old AC 4300 generation.
ACmaxx
ACi
AC centrifugal fans
Accessories
GreenTech EC-compact fan is quieter!
The GreenTech EC-compact fan ACi 4400 is quieter! Quieter than AC fans
and quieter than the existing ACmaxx generation. The reason for this are
the optimised aerodynamics and the drive, which is optimised for minimum structure-borne noise. Thus the fan is only half as loud at comparable air performance, and is up to 6 dB(A) quieter at some operating points.
Speed independent of voltage and frequency
For the GreenTech EC-compact fans ACi 4400, the speed, and thus the air
flow and operating noise, are independent of the supply voltage and
power frequency.
Versions are available for 115 VAC with a voltage range from 85 to
132 VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage
fluctuations and frequency differences in the power system are
compensated for automatically.
185
2016-01
Particular design features of the GreenTech EC-compact fan (ACi 4400):
GreenTech EC-compact fan is more compact!
As large as existing AC fans – and not a bit larger. This is the most
outstanding feature of the new GreenTech EC-compact fans ACi 4400.
Even in the hub area, the fan does not differ from typical
119 x 119 x 38 mm AC fans. Out with the AC, in with the GreenTech
EC-compact fans ACi 4400 – it's that simple.
AC axial fans
Ambient influences
AC fans are extremely common and are used in a wide variety of
applications. In control cabinet cooling, beer coolers, cooling cabinets,
wood-burning stoves, medical devices – all have different requirements
for resistance to ambient influences. ACmaxx and GreenTech EC-compact
fans offer the same features for Humidity protection, splash water and
rough ambient conditions.
Representatives
Safety
• Safety certifications: UL, CSA and VDE 0805 / EN60950.
VDE 0700 / EN60335 on request.
• Our fans have the CE mark of conformity.
• EMC protection:
> EN61000-4-4 Level 1 (1 kV or 2 kV)B
> EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV
> EN61000-4-3
> EN61000-4-6
> EN61000-4-8
> EN55022 Class B
ACmaxx
DC fans - specials
AC
ACmaxx / EC fans
Technical information
about ACmaxx / GreenTech EC-compact fans
AC
Particular design features of the ACmaxx:
Prepared for all common AC voltages
These types have a very wide voltage range from 85 to 265 VAC – the
global voltage range, so to speak. This enables the fan to be used around
the world, opening up large savings potentials. In addition to reduced
logistics effort and stock-keeping, worldwide availability is key. ACmaxx is
compatible with every supply voltage–no switching needed. From 85 to
265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations
in the power system are automatically compensated for.
Higher performance
Unlike conventional AC technology, the state-of-the-art drive concept of
this fan series is not linked to a fixed power frequency. This allows the
motor speed to be increased over a wide range. Thus ACmaxx provides
significantly higher air flow and significantly increased pressure.
2016-01
Higher flexibility
The flexibility of ACmaxx is one-of-a-kind. With its intelligent features,
ACmaxx can be individually adapted to the specific application: standby
mode, overload mode at peak times or night reduction all the way to
temperature-controlled quiet operation are all possible. From speed
186
ACmaxx
ACi
setting to long-term function checks using an alarm or speed signal
outputs, ACmaxx offers optional interfaces that allow you to monitor
operation quickly and easily.
You can find further information about these fan options in the
"Specialised fans" chapter, starting on page 161.
Or you can simply contact our application engineers to discuss your ideal
ACmaxx or GreenTech EC-compact fan.
Information
Fans for AC operation
AC 8300
92 x 38
AC 3200 J
c
119 x 25
c
119 x 32
c
119 x 38
30
50
40
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000 2500
80
188
144
109
189
AC 4400 FN
205
110
190
AC 4300
204
18
191
ACi 4400
100...175
192
350
193
194
Ø 172 x 51
AC 6200 N
Ø 130
W1G 130
220...370
Ø 200
W3G 200
560...1000
196
Ø 250
W3G 250
900...1700
198
40...135
200
Ø 98,5 x 130 AC 100
Subject to alterations
tion
rotec
AC axial fans
fog p
Page
Salt
Go-
d sig
nal
earin
Spee
eve b
c sle
Sinte
VDE
Dim
ensi
, UL,
on
CSA
gs / b
all be
/ No
Go-a
larm
Alarm
with
limit
spee
d
Exte
rnal
temp
eratu
Inter
nal t
re se
emp
nsor
e
ratu
PWM
re se
cont
nsor
rol in
Anal
put
og c
ontr
ol in
Mult
put
i-op
tion
cont
rol in
Hum
put
idity
prot
ectio
IP >
n
= 54
IP 68
aring
s
ACmaxx / EC fans
Overview of technically feasible designs
ACmaxx / ACi axial fans
Series
c
80 x 32
AC 8300
yes
•
•
•
•
•
•
•
–
•
•
– •
188
c
92 x 38
AC 3200 J
no
•
•
•
•
•
•
•
–
•
•
– •
189
c
119 x 25
AC 4400 FN
yes
•
•
•
•
•
•
•
–
•
–
– –
190
c
119 x 32
AC 4300
yes
•
•
•
•
•
•
•
–
•
•
• •
191
c
119 x 38
ACi 4400
yes
–
–
–
–
–
–
–
–
•
•
– •
192
AC 6200 N
yes
•
•
•
•
•
•
•
–
•
•
– •
193
*
–
–
–
–
–
–
–
–
•
•
– –
200
Ø 98,5 x 130 AC 100
p.
AC centrifugal fans
mm
Ø 172 x 51
OPTIONAL
Subject to alterations
– not yet available
• available
DC centrifugal fans
80 x 32
c
20
Sleeve bearings
Ball bearings
Accessories
* Partially granted, partially in registration stage.
187
2016-01
Please note that these special versions are not possible for all voltages and speeds, and not in all combinations.
The special versions are designed for specific customers and projects. As a rule they are not available off the
shelf and are tied to minimum volumes.
Please consult your customer support representative about the feasibility of your special variant.
Representatives
c
10
DC fans - specials
3 3
mm
/h/h
mm
DC axial fans
Page
Air flow
Series
Dimension
Overview of air performance
max.
80 m /h
ACmaxx axial fans
3
 80 x 32 mm
Housing: GRP1) (PBTP)
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via single wires AWG 22,
TR 64
Highlights:
Universally usable for all
mains voltages between 85
and 265 VAC
Mass:
325 g
– Material:
–
–
–
–
–
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go- / NoGo-alarm
- Alarm with limit speed
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54
80
47 115 / 230 50 / 60 85 ... 265
dB(A) Bel(A)
48
6,2
°C
Hours
Hours
8,3
5 000
-20...+75
55 000 / 20 000
92 500
Subject to alterations
Speed variants available on request.
5
22
32 + 0,3
64 + 0,5
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
188
Guard grilles
p. 244
tin-p
lated
Curve
rpm
Life expectancy L10IPC
(40 °C) see page 17
Watts
Service life L10 (Tmax)
ebm-papst Standard
/
Service life L10 (40 °C)
ebm-papst Standard
VAC
Temperature range
Hz
Nominal speed
VAC
Input power
Voltage range
cfm
Sound power level
Frequency
m3/h
Sintec sleeve bearings
Ball bearings
AC 8300 H
Nominal voltage
Type
Air flow
Nominal data
Air flow
Series AC 8300
Sound pressure level
1) Fibreglass-reinforced plastic
➀
Information
144 m /h
ACmaxx axial fans
3
 92 x 38 mm
–
–
–
–
–
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go- / NoGo-alarm
- Alarm with limit speed
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54
DC axial fans
Housing: GRP1) (PBTP)
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via single wires AWG 22,
TR 64
Highlights:
Universally usable for all
mains voltages between 85
and 265 VAC
Mass:
325 g
– Material:
DC centrifugal fans
max.
55
6,4
rpm
°C
Hours
Hours
12
6 800
-20...+70
70 000 / 35 000
117 500
DC fans - specials
85 115 / 230 50 / 60 85 ... 265
Watts
Curve
144
/
Life expectancy L10IPC
(40 °C) see page 17
AC 3200 JH
dB(A) Bel(A)
Service life L10 (Tmax)
ebm-papst Standard
VAC
Service life L10 (40 °C)
ebm-papst Standard
Hz
Temperature range
Voltage range
VAC
Nominal speed
Frequency
cfm
Input power
Nominal voltage
m3/h
Sintec sleeve bearings
Ball bearings
Air flow
Type
Nominal data
Sound power level
Air flow
Series AC 3200 J
Sound pressure level
1) Fibreglass-reinforced plastic
➀
Subject to alterations
6+ 0.3
AC centrifugal fans
61.7+ 0.2
54.2 + 0.15
AC axial fans
ACmaxx / EC fans
Speed variants available on request.
6+ 0.3
38 + 0.5
70.7 + 0.8
0.3
Accessories
ted
Guard grilles
p. 244
189
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Representatives
tin-pla
max.
205 m /h
ACmaxx axial fans
3
 119 x 25 mm
Housing: GRP1) (PBTP)
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via single wires AWG 22,
TR 64
Highlights:
Universally usable for all
mains voltages between
85 and 265 VAC
Mass:
370 g
– Material:
–
–
–
–
–
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go- / NoGo-alarm
- Alarm with limit speed
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
121 115 / 230 50 / 60 85 ... 265
53
6,2
Watts
rpm
°C
Hours
Hours
12
4 850
-20...+70
60 000 / 30 000
102 500
Subject to alterations
Speed variants available on request.
25.4 + 0.15
57.9 + 0.5
tin-pla
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
190
Guard grilles
p. 244
ted
Curve
205
/
Life expectancy L10IPC
(40 °C) see page 17
AC 4400 FNN
dB(A) Bel(A)
Service life L10 (Tmax)
ebm-papst Standard
VAC
Service life L10 (40 °C)
ebm-papst Standard
Hz
Temperature range
Voltage range
VAC
Nominal speed
Frequency
cfm
Input power
Nominal voltage
m3/h
Sintec sleeve bearings
Ball bearings
Air flow
Type
Nominal data
Sound power level
Air flow
Series AC 4400 FN
Sound pressure level
1) Fibreglass-reinforced plastic
➀
Information
3
 119 x 32 mm
Housing: GRP1) (PBTP)
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via single wires AWG 22,
TR 64
Highlights:
Universally usable for all
mains voltages between
85 and 265 VAC
Mass:
325 g
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go- / NoGo-alarm
- Alarm with limit speed
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
– Material:
–
–
–
–
–
51
6,4
rpm
°C
Hours
Hours
12
3 400
-20...+70
45 000 / 22 500
75 500
DC fans - specials
120 115 / 230 50 / 60 85 ... 265
Watts
Curve
204
/
Life expectancy L10IPC
(40 °C) see page 17
AC 4300 H
dB(A) Bel(A)
Service life L10 (Tmax)
ebm-papst Standard
VAC
Service life L10 (40 °C)
ebm-papst Standard
Hz
Temperature range
Voltage range
VAC
Nominal speed
Frequency
cfm
Input power
Nominal voltage
m3/h
Sintec sleeve bearings
Ball bearings
Air flow
Type
Nominal data
Sound power level
Air flow
Series AC 4300
Sound pressure level
1) Fibreglass-reinforced plastic
DC axial fans
ACmaxx axial fans
204 m /h
DC centrifugal fans
max.
➀
Subject to alterations
AC centrifugal fans
O
O
54
52,7
AC axial fans
Rotor protusion
Rotorüberstand
max. 0,4
mm
max.
0,4 mm
ACmaxx / EC fans
Speed variants available on request.
22
ted
191
Representatives
Guard grilles
p. 244
tin-pla
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
64 + 0,6
max.
175 m /h
GreenTech EC-Compact fans
3
 119 x 38 mm
– Possible special versions:
(See chapter DC fans - specials)
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54
Housing: GRP1) (PBT)
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
via 2 flat plugs 2,8 x 0,5 mm
flying leads optional
Highlights:
Fully integrated converter
and fan electronics
Mass:
250 g
– Material:
–
–
–
–
–
4,1
1,7
1 850
-20...+75
65 000 / 25 000
110 000
4,9
2,8
2 700
-20...+75
65 000 / 25 000
110 000
39
5,1
3,2
3 000
-20...+75
65 000 / 25 000
110 000
42
5,3
4,6
3 300
-20...+75
65 000 / 25 000
110 000
➀
➁
➂
➃
42
5,3
4,4
3 300
-20...+75
65 000 / 25 000
110 000
➃
Air flow
Nominal voltage
Frequency
Voltage range
Hz
VAC
ACi 4420 ML
100
59
230
50 / 60 195...265
25
ACi 4420 N
147
86
230
50 / 60 195...265
36
ACi 4420 H
160
94
230
50 / 60 195...265
ACi 4420 HH
175
103
230
50 / 60 195...265
ACi 4410 HH
175
103
115
50 / 60
85...132
dB(A) Bel(A)
Subject to alterations
38 +0,5
6 +0,3
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
192
Guard grilles
p. 244
Connection cables
p. 255
6 +0,3
Curve
Hours
VAC
Life expectancy L10IPC
(40 °C) see page 17
Temperature range
Hours
cfm
Service life L10 (Tmax)
ebm-papst Standard
Nominal speed
°C
m3/h
Service life L10 (40 °C)
ebm-papst Standard
Input power
rpm
Type
Nominal data
Sound power level
Watts
Sound pressure level
/
Air flow
Series ACi 4400
Sintec sleeve bearings
Ball bearings
1) Fibreglass-reinforced plastic
350 m /h
Information
max.
ACmaxx axial fans
3
Ø 172 x 51 mm
–
–
–
DC centrifugal fans
–
–
Housing: Die-cast aluminium
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Counter clockwise, seen
on rotor
Connection:
Via single wires AWG 22,
TR 64
Highlights:
Universally usable for all
mains voltages between
85 and 265 VAC, 50-60 Hz
Housing with grounding lug
for screw M4 x 8 (Torx)
Mass:
900 g
DC axial fans
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go- / NoGo-alarm
- Alarm with limit speed
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54
– Material:
50
5,7
rpm
°C
Hours
Hours
14
2 850
-20...+70
80 000 / 40 000
135 000
DC fans - specials
206 115 / 230 50 / 60 85 ... 265
Watts
Curve
350
/
Life expectancy L10IPC
(40 °C) see page 17
AC 6200 NM
dB(A) Bel(A)
Service life L10 (Tmax)
ebm-papst Standard
VAC
Service life L10 (40 °C)
ebm-papst Standard
Hz
Temperature range
Voltage range
VAC
Nominal speed
Frequency
cfm
Input power
Nominal voltage
m3/h
Sintec sleeve bearings
Ball bearings
Air flow
Type
Nominal data
Sound power level
Air flow
Series AC 6200 N
Sound pressure level
1) Fibreglass-reinforced plastic
➀
Subject to alterations
ACmaxx / EC fans
Speed variants available on request.
AC centrifugal fans
74
63,7
7,5
10
0,8
0,8
7,5
AC axial fans
166
83,3 +0,6
ted
2016-01
ep
193
Representatives
de
Guard grilles
p. 244
tin-pla
8,2
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
15 30,5 +0,2
max.
370 m /h
Energy-saving axial fans
3
Ø 130 mm
(1)
Subject to alterations
Curves:
Mass
M1G 055-AI
Perm. amb. temp.
W1G130-AA25 -01
Max. back-pressure
M1G 055-AI
Max. current draw(1)
W1G130-AA49 -01
Max. input power(1)
Motor
Speed / rpm(1)
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Wall ring: Plastic PP, fibreglass-reinforced
Blades: Plastic PA, fibreglass-reinforced
7
"V", exhaust over struts
Counter-clockwise, seen on rotor
IP 54
"B"
Any
None
Continuous operation (S1)
Maintenance-free ball bearings
VAC
Hz
rpm
W
A
Pa
°C
kg
Electrical connections
– Material:
A
1~ 115
50/60
3 200
24
0,38
90
-30..+60
0,75
p. 264 / J7)
B
1~ 230
50/60
3 200
24
0,19
90
-30..+70
0,75
p. 264 / J7)
Nominal data in operating point with maximum load and 115 or 230 VAC
A
B
2016-01
Air performance measured as per: ISO 5801, Installation category A, in ebm-papst full nozzle and without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
194
n
rpm
Ped
W
I
A
L WA
dB(A)
A
1
3 200
23
0,38
63
A
2
3 200
24
0,38
61
A
3
3 200
24
0,38
60
A
4
3 200
24
0,38
63
A
5
2 800
16
0,26
60
A
6
2 800
16
0,26
58
A
7
2 800
16
0,26
57
A
8
2 800
16
0,26
60
B
1
3 200
23
0,19
63
B
2
3 200
24
0,19
61
B
3
3 200
24
0,19
60
B
4
3 200
24
0,19
63
B
5
2 800
16
0,13
60
B
6
2 800
16
0,13
58
B
7
2 800
16
0,13
57
B
8
2 800
16
0,13
60
Information
Via electronics and TOP
Plug-in connection on motor side
II
DC axial fans
Motor protection:
Electrical connection:
Protection class:
Product conforming
to standards:
– Approvals:
– Speed:
CE; EN 60335-1
VDE, GOST (are available); UL, CSA (are applied for)
Using the programming unit 2 speeds between nmin and nmax can be programmed
❮ "V"
Connection leads
p. 256
Handheld Programmer
p. 256
Electrical connections
p. 264
195
2016-01
Connection lead (total length 450 mm)
is fitted ex works and can be detached.
Representatives
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
–
–
–
–
max.
1 000 m /h
EC axial fans
3
Ø 200 mm
(1)
Pa
Curves:
100
Hz
rpm
W
A
Pa
°C
kg
A
1~ 200-240 50/60 2 900
54
0,55
96
-25..+60
1,6
p. 260 / H3)
B
1~ 200-240 50/60 2 900
54
0,55
96
-25..+60
1,6
p. 261 / H4)
70
60
0,32
0,36
4
A
Step 1
8
0,28
80
3
0,16
20
0,08
10
0,04
30
2
0,12
40
6
pfs
5
0
qV
100
200
200
300
400
400
600
500
800
1
cfm
m3/h
2016-01
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under
the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup,
the specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
196
Ped
W
I
A
L WA
dB(A)
A
1
2 970
50
0,49
65
A
2
2 890
54
0,53
64
A
3
2 830
58
0,56
65
A
4
2 900
54
0,55
70
A
5
2 645
36
0,37
62
A
6
2 575
39
0,40
61
A
7
2 530
42
0,42
62
A
8
2 500
43
0,43
67
B
1
2 970
50
0,49
65
B
2
2 890
54
0,53
64
B
3
2 830
58
0,56
65
B
4
2 900
54
0,55
70
0,20
7
50
n
rpm
A
0,24
Speed-controlled
Not suitable for permanent outdoor use, special version available on request.
B
Step 2
90
(2)
Nominal data in operating point with maximum load and 230 VAC
2 Speed stages
A
B
VAC
0,40 in H2O
Subject to alterations
Mass
M3G 055-BD
Perm. amb. temp.
W3G200-HD01 -03
Max. back-pressure
M3G 055-BD
Max. current draw(1)
W3G200-HD01 -01
Max. input power(1)
Motor
Speed / rpm(1)
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Wall ring: Die-cast aluminium
Blades: Plastic PP
Rotor: Thick layer passivated
7
"V", exhaust over struts
Counter-clockwise, seen on rotor
Depending on installation and position(2)
"B"
Any
None, open rotor
Continuous operation (S1)
Maintenance-free ball bearings
Technical features
and electrical
connection
– Material:
Information
See electrical connections p. 260/61
<= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4)
Via terminal strip
I (if customer has provided connection for protective earth)
DC axial fans
Technical features:
Touch current:
Electrical connection
Protection class:
Product conforming
to standards:
– Approvals:
EN 60335-1, CE
VDE, cURUS
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
–
–
–
–
–
A
Ø4.5 (8x)
Accessories
AC centrifugal fans
22
5
AC axial fans
B
Ø240
Ø260
4
4
Guard grilles
p. 245
Electrical connections
p. 260/261
"V" ›
197
2016-01
"V" ›
Representatives
80±0.3
max.
1 700 m /h
EC axial fans
3
Ø 250 mm
(1)
Pa
100
rpm
W
A
Pa
°C
kg
A
1~ 200-240 50/60 2 330
83
0,72
100
-25...+60
2,1
p. 260 / H3)
B
1~ 200-240 50/60 2 330
83
0,72
100
-25...+60
2,1
p. 261 / H4)
(2)
Nominal data in operating point with maximum load and 230 VAC
Not suitable for permanent outdoor use, special version available on request.
B
A
Step 2
0,32
70
40
30
Step 1
8
2
0,08
10
0,04
6
20
pfs
5
0
qV
100
200
200
400
300
400
600
500
800
600
1000
700
1200
800
1400
900
1600
1
1000 cfm
m3/h
2016-01
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
198
Ped
W
I
A
L WA
dB(A)
A
1
2 465
67
0,59
69
A
2
2 410
75
0,65
69
A
3
2 375
80
0,68
68
A
4
2 330
83
0,72
69
A
5
1 900
33
0,33
63
A
6
1 880
37
0,37
63
A
7
1 860
40
0,38
62
A
8
1 850
42
0,40
63
B
1
2 465
67
0,59
69
B
2
2 410
75
0,65
69
B
3
2 375
80
0,68
68
B
4
2 330
83
0,72
69
0,20
7
0,16
50
3
0,12
60
A
0,24
80
0,28
Speed-controlled
0,36
90
n
rpm
4
2 Speed stages
A
B
Hz
0,40
Curves:
VAC
in H2O
Subject to alterations
Mass
M3G 055-CF
Perm. amb. temp.
W3G250-HH07 -03
Max. back-pressure
M3G 055-CF
Max. current draw(1)
W3G250-HH07 -01
Max. input power(1)
Motor
Speed / rpm(1)
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Wall ring: Die-cast aluminium
Blades: Plastic PP
Rotor: Thick layer passivated
7
"V", exhaust over struts
Counter-clockwise, seen on rotor
Depending on installation and position(2)
"B"
Any
None, open rotor
Continuous operation (S1)
Maintenance-free ball bearings
Technical features
and electrical
connection
– Material:
Information
See electrical connections p. 260/261
<= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4)
Via terminal strip
I (if customer has provided connection for protective earth)
DC axial fans
Technical features:
Touch current:
Electrical connection
Protection class:
Product conforming
to standards:
– Approvals:
EN 60335-1, CE
VDE, cURUS
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
–
–
–
–
–
A
B
7
7
80
"V" ›
Guard grilles
p. 245
Electrical connections
p. 260/261
"V" ›
199
Representatives
Ø5.5+0.2(8x)
Ø295
Ø320
L
2016-01
Ø4.4+0.2(8x)
N
Accessories
PE
AC centrifugal fans
Ø2
90
28
0
AC axial fans
15°
20°
max.
135 m /h
ACmaxx in-line duct fan
3
Ø 98,5 x 130 mm
boost
max.
nominal
boost
nominal
boost
85...265
105
62
79
115/230
50-60
Type high pressure
m3/h
cfm
VAC
Hz
40
23
62
36
115/230
50-60
85...265
115/230
50-60
85...265
53
31
39
at T max
85...265
66
Service life L10
at 40 °C
50-60
135
AC 100 NR-017
Temperature range
115/230
AC 100 HR*
AC 100 MR*
Nominal speed
85...265
47
Hours
4,5
1,8
2 050
5,0
3,8
3 150
4,7
2,5
2 750
35
50-60
80
Input power
AC 100 NR
Hours
40
115/230
32
53
°C
33
Hz
55
rpm
Bel(A)
VAC
90
Sintec sleeve bearings
Ball bearings
AC 100 MR
Watts
dB(A)
cfm
VAC
1) Fibreglass-reinforced plastic
/
VAC
Frequency
nominal
m3/h
Nominal voltage
boost
Type high flow
Air flow
nominal
Nominal data
Air flow
Series AC 100
Sound power level
–
Sound pressure level
–
Voltage range
–
–
–
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- PWM control input
- Analog control input 0…10 VDC
- Humidity protection
- Degree of protection: IP 44 (IP 45
possible depending on mounting
position)
42
5,3
4,5
3 500
tbd
tbd
7,0
4 500
dB(A)
Bel(A)
Watts
rpm
31
4,2
tbd
2 050*
38
4,7
tbd
3 150*
33
4,4
2,8
2 680
40
5,0
3,5
3 300
/
Curve
–
Housing: GRP1) (PBT)
Impeller: GRP1) (PA)
Direction of air flow: Intake over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via 3-pin terminal strip Europa
max. 1,5 mm2
Highlights:
Universally usable for all main
voltages between 85 and 265
VAC, 50-60 Hz, Boost function
Vibration-isolated motor
Optional: new impeller for high
pressure
Two speeds over jumper adjustable
Mass:
400 g
– Material:
-10...+55
70 000 / 50 000
➀
➂
-10...+55
70 000 / 50 000
➁
➃
-10...+55
tbd
➄
°C
Hours
Hours
-10...+55
70 000 / 50 000
➅
➇
-10...+55
70 000 / 50 000
➆
➈
Subject to alterations
* on request
Impeller
Type
high flow
AC 100 MR
high flow
AC 100 NR
high pressure
high pressure
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
200
Boost off,
Jumper low
Boost off,
Jumper high
Boost on
1 250
2 050
3 150
2 200*
2 750
3 500
AC 100 MR*
1 250*
2 050*
3 150*
AC 100 NR-017
2 180
2 680
3 300
Information
DC centrifugal fans
DC axial fans
Highest energy efficiency: 0.03 - 0.045 W/m3/h free air (Specific fan power).
Boost speed setting:
2 speed settings possible via boost function.
Vibration isolation:
Reduced transmission of vibrations from motor to
housing.
Intelligence:
Speed settings and control outputs optional.
Connection
L
Example 3:
Simple connection,
nominal speed
without switching.
DC fans - specials
N
SL
L
N
N
L
L
AC axial fans
Example 4:
Simple connection, boost
speed without switching.
AC centrifugal fans
Jumper Jumper
Low
High
SL
ACmaxx / EC fans
N
Example 2:
Nominal speed via light
switch, separate boost
switch.
201
2016-01
Accessories
Scope of delivery
Representatives
Example 1:
Continuous operation at
nominal speed boost
speed via light switch.
2016-01