Information DC axial fans ACmaxx / EC fans 183 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans 184 187 188 192 194 196 200 2016-01 Technical information about ACmaxx Overview ACmaxx axial fans GreenTech EC-compact fans Energy-saving axial fans EC axial fans ACmaxx in-line duct fan ACmaxx / EC fans Technical information about ACmaxx / GreenTech EC-compact fans AC Progress made by ebm-papst The best example: The ACmaxx fans from ebm-papst, which, thanks to an ingenious yet simple improvement over conventional AC fans, provide substantial benefits. The aim in developing the new ACmaxx series was to raise the technology standard of the conventional AC fan significantly and, in the process, facilitate the transition to the new technology by retaining the overall mounting dimensions. In short, to ensure the fans can be replaced 1:1 without any peripheral changes or changes to the voltage situation. ebm-papst offers two generations of ACmaxx products that meet different needs. 2016-01 What ACmaxx and GreenTech EC-compact fan have in common: Energy efficiency The drive concept is based on state-of-the-art GreenTech EC technology with outstanding motor efficiency. Compared to AC fans of the same size, ACmaxx energy consumption is up to 77% lower–for higher cooling capacity! Just the energy savings means that the products pay for themselves after only a few months. The savings over the entire service life, especially in systems with multiple fans, is considerable. 184 ACmaxx ACi Independent of mains frequency and mains voltage The ACmaxx and GreenTech EC-compact fans are prepared for direct connection to wide ranges of AC voltages and frequencies. The speed, and thus important properties of the fan such as air flow and noise, are independent of the power frequency and do not change, even within the defined voltage range. Voltage fluctuations in the power system are automatically compensated for. Long service life The efficiency of ACmaxx and GreenTech EC-compact fan motors is up to 75% higher than that of conventional AC fan variants. This not only saves energy, it also means less self-heating in the motor. The reduced heating has a direct, positive effect on the bearing system, which is why the fans have a service life that is up to 85% longer! This also extends the service and maintenance intervals significantly. The expense of replacement fans, and even more expensive downtimes, are kept to a manageable minimum. Information DC centrifugal fans DC axial fans ACmaxx / EC fans Technical information about ACmaxx / GreenTech EC-compact fans ACi ACmaxx / EC fans GreenTech EC-compact fan is more efficient! ACmaxx saves energy, and the GreenTech EC-compact fan generation saves even more. While an AC fan at 50 Hz can barely reach an overall efficiency of 5-6%, the ACmaxx makes it to approx. 20-25%. With the new GreenTech EC-compact fans ACi 4400, a remarkable level of up to 30% is reached. This is the result of the optimisation of the entire package made up of drive, electronics, AC/DC conversion and aerodynamics. Thus the new GreenTech EC-compact fans series boasts energy savings of almost 75% compared to the corresponding AC fan, thus providing significantlyhigher savings than the 40% level of the old AC 4300 generation. ACmaxx ACi AC centrifugal fans Accessories GreenTech EC-compact fan is quieter! The GreenTech EC-compact fan ACi 4400 is quieter! Quieter than AC fans and quieter than the existing ACmaxx generation. The reason for this are the optimised aerodynamics and the drive, which is optimised for minimum structure-borne noise. Thus the fan is only half as loud at comparable air performance, and is up to 6 dB(A) quieter at some operating points. Speed independent of voltage and frequency For the GreenTech EC-compact fans ACi 4400, the speed, and thus the air flow and operating noise, are independent of the supply voltage and power frequency. Versions are available for 115 VAC with a voltage range from 85 to 132 VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage fluctuations and frequency differences in the power system are compensated for automatically. 185 2016-01 Particular design features of the GreenTech EC-compact fan (ACi 4400): GreenTech EC-compact fan is more compact! As large as existing AC fans – and not a bit larger. This is the most outstanding feature of the new GreenTech EC-compact fans ACi 4400. Even in the hub area, the fan does not differ from typical 119 x 119 x 38 mm AC fans. Out with the AC, in with the GreenTech EC-compact fans ACi 4400 – it's that simple. AC axial fans Ambient influences AC fans are extremely common and are used in a wide variety of applications. In control cabinet cooling, beer coolers, cooling cabinets, wood-burning stoves, medical devices – all have different requirements for resistance to ambient influences. ACmaxx and GreenTech EC-compact fans offer the same features for Humidity protection, splash water and rough ambient conditions. Representatives Safety • Safety certifications: UL, CSA and VDE 0805 / EN60950. VDE 0700 / EN60335 on request. • Our fans have the CE mark of conformity. • EMC protection: > EN61000-4-4 Level 1 (1 kV or 2 kV)B > EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV > EN61000-4-3 > EN61000-4-6 > EN61000-4-8 > EN55022 Class B ACmaxx DC fans - specials AC ACmaxx / EC fans Technical information about ACmaxx / GreenTech EC-compact fans AC Particular design features of the ACmaxx: Prepared for all common AC voltages These types have a very wide voltage range from 85 to 265 VAC – the global voltage range, so to speak. This enables the fan to be used around the world, opening up large savings potentials. In addition to reduced logistics effort and stock-keeping, worldwide availability is key. ACmaxx is compatible with every supply voltage–no switching needed. From 85 to 265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations in the power system are automatically compensated for. Higher performance Unlike conventional AC technology, the state-of-the-art drive concept of this fan series is not linked to a fixed power frequency. This allows the motor speed to be increased over a wide range. Thus ACmaxx provides significantly higher air flow and significantly increased pressure. 2016-01 Higher flexibility The flexibility of ACmaxx is one-of-a-kind. With its intelligent features, ACmaxx can be individually adapted to the specific application: standby mode, overload mode at peak times or night reduction all the way to temperature-controlled quiet operation are all possible. From speed 186 ACmaxx ACi setting to long-term function checks using an alarm or speed signal outputs, ACmaxx offers optional interfaces that allow you to monitor operation quickly and easily. You can find further information about these fan options in the "Specialised fans" chapter, starting on page 161. Or you can simply contact our application engineers to discuss your ideal ACmaxx or GreenTech EC-compact fan. Information Fans for AC operation AC 8300 92 x 38 AC 3200 J c 119 x 25 c 119 x 32 c 119 x 38 30 50 40 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 80 188 144 109 189 AC 4400 FN 205 110 190 AC 4300 204 18 191 ACi 4400 100...175 192 350 193 194 Ø 172 x 51 AC 6200 N Ø 130 W1G 130 220...370 Ø 200 W3G 200 560...1000 196 Ø 250 W3G 250 900...1700 198 40...135 200 Ø 98,5 x 130 AC 100 Subject to alterations tion rotec AC axial fans fog p Page Salt Go- d sig nal earin Spee eve b c sle Sinte VDE Dim ensi , UL, on CSA gs / b all be / No Go-a larm Alarm with limit spee d Exte rnal temp eratu Inter nal t re se emp nsor e ratu PWM re se cont nsor rol in Anal put og c ontr ol in Mult put i-op tion cont rol in Hum put idity prot ectio IP > n = 54 IP 68 aring s ACmaxx / EC fans Overview of technically feasible designs ACmaxx / ACi axial fans Series c 80 x 32 AC 8300 yes • • • • • • • – • • – • 188 c 92 x 38 AC 3200 J no • • • • • • • – • • – • 189 c 119 x 25 AC 4400 FN yes • • • • • • • – • – – – 190 c 119 x 32 AC 4300 yes • • • • • • • – • • • • 191 c 119 x 38 ACi 4400 yes – – – – – – – – • • – • 192 AC 6200 N yes • • • • • • • – • • – • 193 * – – – – – – – – • • – – 200 Ø 98,5 x 130 AC 100 p. AC centrifugal fans mm Ø 172 x 51 OPTIONAL Subject to alterations – not yet available • available DC centrifugal fans 80 x 32 c 20 Sleeve bearings Ball bearings Accessories * Partially granted, partially in registration stage. 187 2016-01 Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. Representatives c 10 DC fans - specials 3 3 mm /h/h mm DC axial fans Page Air flow Series Dimension Overview of air performance max. 80 m /h ACmaxx axial fans 3 80 x 32 mm Housing: GRP1) (PBTP) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via single wires AWG 22, TR 64 Highlights: Universally usable for all mains voltages between 85 and 265 VAC Mass: 325 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go- / NoGo-alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection - Salt fog protection - Degree of protection: IP 54 80 47 115 / 230 50 / 60 85 ... 265 dB(A) Bel(A) 48 6,2 °C Hours Hours 8,3 5 000 -20...+75 55 000 / 20 000 92 500 Subject to alterations Speed variants available on request. 5 22 32 + 0,3 64 + 0,5 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 188 Guard grilles p. 244 tin-p lated Curve rpm Life expectancy L10IPC (40 °C) see page 17 Watts Service life L10 (Tmax) ebm-papst Standard / Service life L10 (40 °C) ebm-papst Standard VAC Temperature range Hz Nominal speed VAC Input power Voltage range cfm Sound power level Frequency m3/h Sintec sleeve bearings Ball bearings AC 8300 H Nominal voltage Type Air flow Nominal data Air flow Series AC 8300 Sound pressure level 1) Fibreglass-reinforced plastic ➀ Information 144 m /h ACmaxx axial fans 3 92 x 38 mm – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go- / NoGo-alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection - Salt fog protection - Degree of protection: IP 54 DC axial fans Housing: GRP1) (PBTP) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via single wires AWG 22, TR 64 Highlights: Universally usable for all mains voltages between 85 and 265 VAC Mass: 325 g – Material: DC centrifugal fans max. 55 6,4 rpm °C Hours Hours 12 6 800 -20...+70 70 000 / 35 000 117 500 DC fans - specials 85 115 / 230 50 / 60 85 ... 265 Watts Curve 144 / Life expectancy L10IPC (40 °C) see page 17 AC 3200 JH dB(A) Bel(A) Service life L10 (Tmax) ebm-papst Standard VAC Service life L10 (40 °C) ebm-papst Standard Hz Temperature range Voltage range VAC Nominal speed Frequency cfm Input power Nominal voltage m3/h Sintec sleeve bearings Ball bearings Air flow Type Nominal data Sound power level Air flow Series AC 3200 J Sound pressure level 1) Fibreglass-reinforced plastic ➀ Subject to alterations 6+ 0.3 AC centrifugal fans 61.7+ 0.2 54.2 + 0.15 AC axial fans ACmaxx / EC fans Speed variants available on request. 6+ 0.3 38 + 0.5 70.7 + 0.8 0.3 Accessories ted Guard grilles p. 244 189 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Representatives tin-pla max. 205 m /h ACmaxx axial fans 3 119 x 25 mm Housing: GRP1) (PBTP) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via single wires AWG 22, TR 64 Highlights: Universally usable for all mains voltages between 85 and 265 VAC Mass: 370 g – Material: – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go- / NoGo-alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection 121 115 / 230 50 / 60 85 ... 265 53 6,2 Watts rpm °C Hours Hours 12 4 850 -20...+70 60 000 / 30 000 102 500 Subject to alterations Speed variants available on request. 25.4 + 0.15 57.9 + 0.5 tin-pla 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 190 Guard grilles p. 244 ted Curve 205 / Life expectancy L10IPC (40 °C) see page 17 AC 4400 FNN dB(A) Bel(A) Service life L10 (Tmax) ebm-papst Standard VAC Service life L10 (40 °C) ebm-papst Standard Hz Temperature range Voltage range VAC Nominal speed Frequency cfm Input power Nominal voltage m3/h Sintec sleeve bearings Ball bearings Air flow Type Nominal data Sound power level Air flow Series AC 4400 FN Sound pressure level 1) Fibreglass-reinforced plastic ➀ Information 3 119 x 32 mm Housing: GRP1) (PBTP) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via single wires AWG 22, TR 64 Highlights: Universally usable for all mains voltages between 85 and 265 VAC Mass: 325 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go- / NoGo-alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection - Salt fog protection - Degree of protection: IP 54 / IP 68 – Material: – – – – – 51 6,4 rpm °C Hours Hours 12 3 400 -20...+70 45 000 / 22 500 75 500 DC fans - specials 120 115 / 230 50 / 60 85 ... 265 Watts Curve 204 / Life expectancy L10IPC (40 °C) see page 17 AC 4300 H dB(A) Bel(A) Service life L10 (Tmax) ebm-papst Standard VAC Service life L10 (40 °C) ebm-papst Standard Hz Temperature range Voltage range VAC Nominal speed Frequency cfm Input power Nominal voltage m3/h Sintec sleeve bearings Ball bearings Air flow Type Nominal data Sound power level Air flow Series AC 4300 Sound pressure level 1) Fibreglass-reinforced plastic DC axial fans ACmaxx axial fans 204 m /h DC centrifugal fans max. ➀ Subject to alterations AC centrifugal fans O O 54 52,7 AC axial fans Rotor protusion Rotorüberstand max. 0,4 mm max. 0,4 mm ACmaxx / EC fans Speed variants available on request. 22 ted 191 Representatives Guard grilles p. 244 tin-pla 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Accessories 64 + 0,6 max. 175 m /h GreenTech EC-Compact fans 3 119 x 38 mm – Possible special versions: (See chapter DC fans - specials) - Humidity protection - Salt fog protection - Degree of protection: IP 54 Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: via 2 flat plugs 2,8 x 0,5 mm flying leads optional Highlights: Fully integrated converter and fan electronics Mass: 250 g – Material: – – – – – 4,1 1,7 1 850 -20...+75 65 000 / 25 000 110 000 4,9 2,8 2 700 -20...+75 65 000 / 25 000 110 000 39 5,1 3,2 3 000 -20...+75 65 000 / 25 000 110 000 42 5,3 4,6 3 300 -20...+75 65 000 / 25 000 110 000 ➀ ➁ ➂ ➃ 42 5,3 4,4 3 300 -20...+75 65 000 / 25 000 110 000 ➃ Air flow Nominal voltage Frequency Voltage range Hz VAC ACi 4420 ML 100 59 230 50 / 60 195...265 25 ACi 4420 N 147 86 230 50 / 60 195...265 36 ACi 4420 H 160 94 230 50 / 60 195...265 ACi 4420 HH 175 103 230 50 / 60 195...265 ACi 4410 HH 175 103 115 50 / 60 85...132 dB(A) Bel(A) Subject to alterations 38 +0,5 6 +0,3 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 192 Guard grilles p. 244 Connection cables p. 255 6 +0,3 Curve Hours VAC Life expectancy L10IPC (40 °C) see page 17 Temperature range Hours cfm Service life L10 (Tmax) ebm-papst Standard Nominal speed °C m3/h Service life L10 (40 °C) ebm-papst Standard Input power rpm Type Nominal data Sound power level Watts Sound pressure level / Air flow Series ACi 4400 Sintec sleeve bearings Ball bearings 1) Fibreglass-reinforced plastic 350 m /h Information max. ACmaxx axial fans 3 Ø 172 x 51 mm – – – DC centrifugal fans – – Housing: Die-cast aluminium Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counter clockwise, seen on rotor Connection: Via single wires AWG 22, TR 64 Highlights: Universally usable for all mains voltages between 85 and 265 VAC, 50-60 Hz Housing with grounding lug for screw M4 x 8 (Torx) Mass: 900 g DC axial fans – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go- / NoGo-alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection - Salt fog protection - Degree of protection: IP 54 – Material: 50 5,7 rpm °C Hours Hours 14 2 850 -20...+70 80 000 / 40 000 135 000 DC fans - specials 206 115 / 230 50 / 60 85 ... 265 Watts Curve 350 / Life expectancy L10IPC (40 °C) see page 17 AC 6200 NM dB(A) Bel(A) Service life L10 (Tmax) ebm-papst Standard VAC Service life L10 (40 °C) ebm-papst Standard Hz Temperature range Voltage range VAC Nominal speed Frequency cfm Input power Nominal voltage m3/h Sintec sleeve bearings Ball bearings Air flow Type Nominal data Sound power level Air flow Series AC 6200 N Sound pressure level 1) Fibreglass-reinforced plastic ➀ Subject to alterations ACmaxx / EC fans Speed variants available on request. AC centrifugal fans 74 63,7 7,5 10 0,8 0,8 7,5 AC axial fans 166 83,3 +0,6 ted 2016-01 ep 193 Representatives de Guard grilles p. 244 tin-pla 8,2 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Accessories 15 30,5 +0,2 max. 370 m /h Energy-saving axial fans 3 Ø 130 mm (1) Subject to alterations Curves: Mass M1G 055-AI Perm. amb. temp. W1G130-AA25 -01 Max. back-pressure M1G 055-AI Max. current draw(1) W1G130-AA49 -01 Max. input power(1) Motor Speed / rpm(1) Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Wall ring: Plastic PP, fibreglass-reinforced Blades: Plastic PA, fibreglass-reinforced 7 "V", exhaust over struts Counter-clockwise, seen on rotor IP 54 "B" Any None Continuous operation (S1) Maintenance-free ball bearings VAC Hz rpm W A Pa °C kg Electrical connections – Material: A 1~ 115 50/60 3 200 24 0,38 90 -30..+60 0,75 p. 264 / J7) B 1~ 230 50/60 3 200 24 0,19 90 -30..+70 0,75 p. 264 / J7) Nominal data in operating point with maximum load and 115 or 230 VAC A B 2016-01 Air performance measured as per: ISO 5801, Installation category A, in ebm-papst full nozzle and without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions 194 n rpm Ped W I A L WA dB(A) A 1 3 200 23 0,38 63 A 2 3 200 24 0,38 61 A 3 3 200 24 0,38 60 A 4 3 200 24 0,38 63 A 5 2 800 16 0,26 60 A 6 2 800 16 0,26 58 A 7 2 800 16 0,26 57 A 8 2 800 16 0,26 60 B 1 3 200 23 0,19 63 B 2 3 200 24 0,19 61 B 3 3 200 24 0,19 60 B 4 3 200 24 0,19 63 B 5 2 800 16 0,13 60 B 6 2 800 16 0,13 58 B 7 2 800 16 0,13 57 B 8 2 800 16 0,13 60 Information Via electronics and TOP Plug-in connection on motor side II DC axial fans Motor protection: Electrical connection: Protection class: Product conforming to standards: – Approvals: – Speed: CE; EN 60335-1 VDE, GOST (are available); UL, CSA (are applied for) Using the programming unit 2 speeds between nmin and nmax can be programmed ❮ "V" Connection leads p. 256 Handheld Programmer p. 256 Electrical connections p. 264 195 2016-01 Connection lead (total length 450 mm) is fitted ex works and can be detached. Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans – – – – max. 1 000 m /h EC axial fans 3 Ø 200 mm (1) Pa Curves: 100 Hz rpm W A Pa °C kg A 1~ 200-240 50/60 2 900 54 0,55 96 -25..+60 1,6 p. 260 / H3) B 1~ 200-240 50/60 2 900 54 0,55 96 -25..+60 1,6 p. 261 / H4) 70 60 0,32 0,36 4 A Step 1 8 0,28 80 3 0,16 20 0,08 10 0,04 30 2 0,12 40 6 pfs 5 0 qV 100 200 200 300 400 400 600 500 800 1 cfm m3/h 2016-01 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions 196 Ped W I A L WA dB(A) A 1 2 970 50 0,49 65 A 2 2 890 54 0,53 64 A 3 2 830 58 0,56 65 A 4 2 900 54 0,55 70 A 5 2 645 36 0,37 62 A 6 2 575 39 0,40 61 A 7 2 530 42 0,42 62 A 8 2 500 43 0,43 67 B 1 2 970 50 0,49 65 B 2 2 890 54 0,53 64 B 3 2 830 58 0,56 65 B 4 2 900 54 0,55 70 0,20 7 50 n rpm A 0,24 Speed-controlled Not suitable for permanent outdoor use, special version available on request. B Step 2 90 (2) Nominal data in operating point with maximum load and 230 VAC 2 Speed stages A B VAC 0,40 in H2O Subject to alterations Mass M3G 055-BD Perm. amb. temp. W3G200-HD01 -03 Max. back-pressure M3G 055-BD Max. current draw(1) W3G200-HD01 -01 Max. input power(1) Motor Speed / rpm(1) Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Wall ring: Die-cast aluminium Blades: Plastic PP Rotor: Thick layer passivated 7 "V", exhaust over struts Counter-clockwise, seen on rotor Depending on installation and position(2) "B" Any None, open rotor Continuous operation (S1) Maintenance-free ball bearings Technical features and electrical connection – Material: Information See electrical connections p. 260/61 <= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4) Via terminal strip I (if customer has provided connection for protective earth) DC axial fans Technical features: Touch current: Electrical connection Protection class: Product conforming to standards: – Approvals: EN 60335-1, CE VDE, cURUS ACmaxx / EC fans DC fans - specials DC centrifugal fans – – – – – A Ø4.5 (8x) Accessories AC centrifugal fans 22 5 AC axial fans B Ø240 Ø260 4 4 Guard grilles p. 245 Electrical connections p. 260/261 "V" › 197 2016-01 "V" › Representatives 80±0.3 max. 1 700 m /h EC axial fans 3 Ø 250 mm (1) Pa 100 rpm W A Pa °C kg A 1~ 200-240 50/60 2 330 83 0,72 100 -25...+60 2,1 p. 260 / H3) B 1~ 200-240 50/60 2 330 83 0,72 100 -25...+60 2,1 p. 261 / H4) (2) Nominal data in operating point with maximum load and 230 VAC Not suitable for permanent outdoor use, special version available on request. B A Step 2 0,32 70 40 30 Step 1 8 2 0,08 10 0,04 6 20 pfs 5 0 qV 100 200 200 400 300 400 600 500 800 600 1000 700 1200 800 1400 900 1600 1 1000 cfm m3/h 2016-01 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions 198 Ped W I A L WA dB(A) A 1 2 465 67 0,59 69 A 2 2 410 75 0,65 69 A 3 2 375 80 0,68 68 A 4 2 330 83 0,72 69 A 5 1 900 33 0,33 63 A 6 1 880 37 0,37 63 A 7 1 860 40 0,38 62 A 8 1 850 42 0,40 63 B 1 2 465 67 0,59 69 B 2 2 410 75 0,65 69 B 3 2 375 80 0,68 68 B 4 2 330 83 0,72 69 0,20 7 0,16 50 3 0,12 60 A 0,24 80 0,28 Speed-controlled 0,36 90 n rpm 4 2 Speed stages A B Hz 0,40 Curves: VAC in H2O Subject to alterations Mass M3G 055-CF Perm. amb. temp. W3G250-HH07 -03 Max. back-pressure M3G 055-CF Max. current draw(1) W3G250-HH07 -01 Max. input power(1) Motor Speed / rpm(1) Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Wall ring: Die-cast aluminium Blades: Plastic PP Rotor: Thick layer passivated 7 "V", exhaust over struts Counter-clockwise, seen on rotor Depending on installation and position(2) "B" Any None, open rotor Continuous operation (S1) Maintenance-free ball bearings Technical features and electrical connection – Material: Information See electrical connections p. 260/261 <= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4) Via terminal strip I (if customer has provided connection for protective earth) DC axial fans Technical features: Touch current: Electrical connection Protection class: Product conforming to standards: – Approvals: EN 60335-1, CE VDE, cURUS ACmaxx / EC fans DC fans - specials DC centrifugal fans – – – – – A B 7 7 80 "V" › Guard grilles p. 245 Electrical connections p. 260/261 "V" › 199 Representatives Ø5.5+0.2(8x) Ø295 Ø320 L 2016-01 Ø4.4+0.2(8x) N Accessories PE AC centrifugal fans Ø2 90 28 0 AC axial fans 15° 20° max. 135 m /h ACmaxx in-line duct fan 3 Ø 98,5 x 130 mm boost max. nominal boost nominal boost 85...265 105 62 79 115/230 50-60 Type high pressure m3/h cfm VAC Hz 40 23 62 36 115/230 50-60 85...265 115/230 50-60 85...265 53 31 39 at T max 85...265 66 Service life L10 at 40 °C 50-60 135 AC 100 NR-017 Temperature range 115/230 AC 100 HR* AC 100 MR* Nominal speed 85...265 47 Hours 4,5 1,8 2 050 5,0 3,8 3 150 4,7 2,5 2 750 35 50-60 80 Input power AC 100 NR Hours 40 115/230 32 53 °C 33 Hz 55 rpm Bel(A) VAC 90 Sintec sleeve bearings Ball bearings AC 100 MR Watts dB(A) cfm VAC 1) Fibreglass-reinforced plastic / VAC Frequency nominal m3/h Nominal voltage boost Type high flow Air flow nominal Nominal data Air flow Series AC 100 Sound power level – Sound pressure level – Voltage range – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - PWM control input - Analog control input 0…10 VDC - Humidity protection - Degree of protection: IP 44 (IP 45 possible depending on mounting position) 42 5,3 4,5 3 500 tbd tbd 7,0 4 500 dB(A) Bel(A) Watts rpm 31 4,2 tbd 2 050* 38 4,7 tbd 3 150* 33 4,4 2,8 2 680 40 5,0 3,5 3 300 / Curve – Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Intake over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 3-pin terminal strip Europa max. 1,5 mm2 Highlights: Universally usable for all main voltages between 85 and 265 VAC, 50-60 Hz, Boost function Vibration-isolated motor Optional: new impeller for high pressure Two speeds over jumper adjustable Mass: 400 g – Material: -10...+55 70 000 / 50 000 ➀ ➂ -10...+55 70 000 / 50 000 ➁ ➃ -10...+55 tbd ➄ °C Hours Hours -10...+55 70 000 / 50 000 ➅ ➇ -10...+55 70 000 / 50 000 ➆ ➈ Subject to alterations * on request Impeller Type high flow AC 100 MR high flow AC 100 NR high pressure high pressure 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 200 Boost off, Jumper low Boost off, Jumper high Boost on 1 250 2 050 3 150 2 200* 2 750 3 500 AC 100 MR* 1 250* 2 050* 3 150* AC 100 NR-017 2 180 2 680 3 300 Information DC centrifugal fans DC axial fans Highest energy efficiency: 0.03 - 0.045 W/m3/h free air (Specific fan power). Boost speed setting: 2 speed settings possible via boost function. Vibration isolation: Reduced transmission of vibrations from motor to housing. Intelligence: Speed settings and control outputs optional. Connection L Example 3: Simple connection, nominal speed without switching. DC fans - specials N SL L N N L L AC axial fans Example 4: Simple connection, boost speed without switching. AC centrifugal fans Jumper Jumper Low High SL ACmaxx / EC fans N Example 2: Nominal speed via light switch, separate boost switch. 201 2016-01 Accessories Scope of delivery Representatives Example 1: Continuous operation at nominal speed boost speed via light switch. 2016-01 202