MA-COM SMD050

PolySwitch®
PTC Devices
Tyco / Electronics
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025
Phone: 800-227-4856
Fax: 800-227-4866
PRODUCT: SMD050
DOCUMENT: SCD 21828
PCN: 744611
REV LETTER: F
REV DATE: MAY 31, 2002
PAGE NO.: 1 OF 1
Overcurrent Protection Device
Specification Status: Released
Maximum Electrical Ratings
Operating Voltage / Interrupt Current
60V / 10A
12V / 60A
5V / 125A
Marking:
050
Manufacturer’s Mark
Part Identification
Notes:
1. All metal surfaces are tin plated.
2. Devices cannot be wave soldered.
3. Drawing not to scale.
TABLE I. DIMENSIONS:
A
MIN
MAX
mm: 6.73
7.98
in*: (0.265) (0.314)
B
MIN
---
C
D
E
F
G
H
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
3.18
4.8
5.44
0.56
0.71
0.20
0.30
2.16
2.41
0.66
1.37
0.43
(0.125) (0.19) (0.214) (0.022) (0.028) (0.008) (0.012) (0.085) (0.095) (0.026) (0.054) (0.017)
*Rounded off approximation
TABLE II. PERFORMANCE RATINGS:
CURRENT RATINGS**
AMPS
AT 0°C
HOLD TRIP
0.55
1.10
AMPS
AT 20°C
HOLD TRIP
0.50
1.00
TIME TO
TRIP**
AMPS
SECONDS AT
AT 60°C
20°C, 2.5A
HOLD TRIP
MAX
0.33
0.66
4
RESISTANCE
VALUES
OHMS
AT 20°C
MIN
MAX*
0.35
1.4
TRIPPED-STATE
POWER
DISSIPATION**
WATTS AT
20°C
MAX
1.7
* Maximum resistance is measured 1 hour after reflow.
** Values specified were determined using PCB’s with 0.070”X1.5 ounce copper traces.
Reference Documents:
Precedence:
Effectivity:
CAUTION:
PS300, E.N. SMD 1.0x
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.