4W DC-DC Converter P4Z-Series ● ● ● ● ● ● ● Wide 4:1 input range Full SMD technology Up to 3500 VDC isolation MTBF > 0.96 MHours Continuous short circuit protection Low profile metal package available Mobile / battery driven applications, Distributed power networks, Data communications equipments, Telecommunication instruments, Process / machine control equipments Model selection guide Typ Input nominal voltage [VDC] Single output P4Z243R3S4 9...36 P4Z2405S4 9...36 P4Z2409S4 9...36 P4Z2412S4 9...36 P4Z2415S4 9...36 P4Z2418S4 9...36 P4Z2424S4 9...36 P4Z483R3S4 18...72 P4Z4805S4 18...72 P4Z4809S4 18...72 P4Z4812S4 18...72 P4Z4815S4 18...72 P4Z4818S4 18...72 P4Z4824S4 18...72 Dual output P4Z243R3D4 9...36 P4Z2405D4 9...36 P4Z2409D4 9...36 P4Z2412D4 9...36 P4Z2415D4 9...36 P4Z2418D4 9...36 P4Z2424D4 9...36 P4Z483R3D4 18...72 P4Z4805D4 18...72 P4Z4809D4 18...72 P4Z4812D4 18...72 P4Z4815D4 18...72 P4Z4818D4 18...72 P4Z4824D4 18...72 Output voltage [VDC] Output current [mA] Efficiency typ. [%] 3.3 5.0 9.0 12.0 15.0 18.0 24.0 3.3 5.0 9.0 12.0 15.0 18.0 24.0 1200 800 445 333 267 223 167 1200 800 445 333 267 223 167 77 80 80 83 83 80 81 77 80 82 81 81 81 82 ±3.3 ±5.0 ±9.0 ±12.0 ±15.0 ±18.0 ±24.0 ±3.3 ±5.0 ±9.0 ±12.0 ±15.0 ±18.0 ±24.0 ±600 ±400 ±223 ±167 ±134 ±112 ±84 ±600 ±400 ±223 ±167 ±134 ±112 ±84 76 78 80 82 80 80 80 75 79 81 82 81 80 80 Input voltage range reach from 9V to 72V and the output voltage range reach from 3.3V to 24V Suffix: “H” for 3.5kV isolation voltage Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 4W DC-DC Converter P4Z-Series Specifications Input : Voltage range General: Efficiency Switching frequency Environmental: Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity 24 VDC, 9…36 VDC 48 VDC, 36…72 VDC Pi Network Filter Isolation: Rated voltage Resistance Capacitance Output: Voltage accuracy Voltage balance (dual outputs) Ripple and noise (at 20 MHz BW) Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient 1500 VDC, Standard 3500 VDC, Suffix “H” 109 Ω 390 pF, typ. ± 1%, max. ± 1% Cooling Physical : Dimensions Weight 60 mVp-p, max. Continuous Automatic ± 0.5%, max. ± 0.5%, max. ± 0.02% / °C 72% to 78% 260 kHz, typ. -40 °C to +85 °C 100 °C max. -40 °C to +125 °C None required Up to 90%, non-condensing Free-air convection 31.75x20.32x10.16 mm 26 g metal, standard, 21.5 g plastic suffix “P” Standard, nickel-coated copper metal Case material Dimensions 27.94 31.75 0.5 1 P4Z2405D4 PHI-CON 20.32 12 24 All dimensions in mm Tolerance ±0.25 mm Pin connections Pin Standard Single Dual 1 +V Input +V Input 2 N.C. -V Output 3 N.C. Common 9 Omitted Omitted 10 -V Output Common 11 +V Output +V Output 12 -V Input -V Input 13 -V Input -V Input 14 +V Output +V Output 15 -V Output Common 16 Omitted Omitted 22 N.C. Common 23 N.C. -V Output 24 +V Input +V Input 15.24 bottom view 3.5KVDC Single Dual Omitted Omitted -V Input -V Input -V Input -V Input Omitted Common Omitted Omitted N.C. -V Output Omitted Omitted Omitted Omitted +V Output +V Output Omitted Omitted -V Output Common +V Input +V Input +V Input +V Input Omitted Omitted 0.5 13 2.54 10.16 3.05 min. Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 5.05 f Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]