Download

4W DC-DC Converter P4Z-Series
●
●
●
●
●
●
●
Wide 4:1 input range
Full SMD technology
Up to 3500 VDC isolation
MTBF > 0.96 MHours
Continuous short circuit protection
Low profile metal package available
Mobile / battery driven applications,
Distributed power networks,
Data communications equipments,
Telecommunication instruments,
Process / machine control equipments
Model selection guide
Typ
Input nominal
voltage
[VDC]
Single output
P4Z243R3S4
9...36
P4Z2405S4
9...36
P4Z2409S4
9...36
P4Z2412S4
9...36
P4Z2415S4
9...36
P4Z2418S4
9...36
P4Z2424S4
9...36
P4Z483R3S4
18...72
P4Z4805S4
18...72
P4Z4809S4
18...72
P4Z4812S4
18...72
P4Z4815S4
18...72
P4Z4818S4
18...72
P4Z4824S4
18...72
Dual output
P4Z243R3D4
9...36
P4Z2405D4
9...36
P4Z2409D4
9...36
P4Z2412D4
9...36
P4Z2415D4
9...36
P4Z2418D4
9...36
P4Z2424D4
9...36
P4Z483R3D4
18...72
P4Z4805D4
18...72
P4Z4809D4
18...72
P4Z4812D4
18...72
P4Z4815D4
18...72
P4Z4818D4
18...72
P4Z4824D4
18...72
Output voltage
[VDC]
Output current
[mA]
Efficiency typ.
[%]
3.3
5.0
9.0
12.0
15.0
18.0
24.0
3.3
5.0
9.0
12.0
15.0
18.0
24.0
1200
800
445
333
267
223
167
1200
800
445
333
267
223
167
77
80
80
83
83
80
81
77
80
82
81
81
81
82
±3.3
±5.0
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±18.0
±24.0
±600
±400
±223
±167
±134
±112
±84
±600
±400
±223
±167
±134
±112
±84
76
78
80
82
80
80
80
75
79
81
82
81
80
80
Input voltage range reach from 9V to 72V and the output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
4W DC-DC Converter P4Z-Series
Specifications
Input :
Voltage range
General:
Efficiency
Switching frequency
Environmental:
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
24 VDC, 9…36 VDC
48 VDC, 36…72 VDC
Pi Network
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output:
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
± 1%, max.
± 1%
Cooling
Physical :
Dimensions
Weight
60 mVp-p, max.
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
72% to 78%
260 kHz, typ.
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
31.75x20.32x10.16 mm
26 g metal, standard,
21.5 g plastic suffix “P”
Standard, nickel-coated
copper metal
Case material
Dimensions
27.94
31.75
0.5
1
P4Z2405D4
PHI-CON
20.32
12
24
All dimensions in mm
Tolerance ±0.25 mm
Pin connections
Pin
Standard
Single
Dual
1 +V Input
+V Input
2 N.C.
-V Output
3 N.C.
Common
9 Omitted
Omitted
10 -V Output Common
11 +V Output +V Output
12 -V Input
-V Input
13 -V Input
-V Input
14 +V Output +V Output
15 -V Output Common
16 Omitted
Omitted
22 N.C.
Common
23 N.C.
-V Output
24 +V Input
+V Input
15.24
bottom view
3.5KVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output +V Output
Omitted
Omitted
-V Output Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
0.5
13
2.54
10.16
3.05 min.
Life Support Policy: HY-LINE does not authorize the use of
any of its products for use in life support devices or
systems without the express written approval of an officer
of the Company. Life support systems are devices which
support or sustain life, and whose failure to perform, when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 5.05 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]