Download

3W DC-DC Converter P3C-Series
●
●
●
●
●
●
●
●
●
●
Wide 4:1 input range
Up to 3500 VDC isolation
Continuous short circuit protection
Low profile metal package available
Mobile / battery driven applications
Distributed power networks
Data communications equipments
Telecommunication instruments
Process / machine control equipments
MTBF >1.03 MHours
Model selection guide
Typ
Input nominal
Output voltage
voltage
[VDC]
[VDC]
Single output
P3C243R3S3
9…36
3.3
P3C2405S3
9…36
5.0
P3C2409S3
9…36
9.0
P3C2412S3
9…36
12.0
P3C2415S3
9…36
15.0
P3C2418S3
9…36
18.0
P3C2424S3
9…36
24.0
P3C483R3S3
18…72
3.3
P3C4805S3
18…72
5.0
P3C4809S3
18…72
9.0
P3C4812S3
18…72
12.0
P3C4815S3
18…72
15.0
P3C4818S3
18…72
18.0
P3C4824S3
18…72
24.0
Dual output
P3C243R3D3
9…36
±3.3
P3C2405D3
9…36
±5.0
P3C2409D3
9…36
±9.0
P3C2412D3
9…36
±12.0
P3C2415D3
9…36
±15.0
P3C2418D3
9…36
±18.0
P3C2424D3
9…36
±24.0
P3C483R3D3
18…72
±3.3
P3C4805D3
18…72
±5.0
P3C4809D3
18…72
±9.0
P3C4812D3
18…72
±12.0
P3C4815D3
18…72
±15.0
P3C4818D3
18…72
±18.0
P3C4824D3
18…72
±24.0
Notes: Suffix “H” 3500 VDC instead of 1500 VDC isolation.
Output current
[mA]
Efficiency typ.
[%]
900
600
334
250
200
167
125
900
600
334
250
200
167
125
75
78
79
81
81
81
81
76
79
79
80
80
81
80
±450
±300
±167
±125
±100
±84
±63
±450
±300
±167
±125
±100
±84
±63
76
79
79
80
80
81
80
76
81
82
81
82
81
81
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
3W DC-DC Converter P3C-Series
Specifications
Input
Voltage range
General
Efficiency
Switching frequency
Environmental
Operating temperature
(ambient)
Case temperature
Storage temperature
Derating
Humidity
24 VDC, 9..36 VDC
48 VDC, 18..72 VDC
Pi Network
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
± 1%, max.
± 1%
Cooling
Physical
Dimensions
Weight
60 mVp-p, max.
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
72% to 78%
260 kHz, typ.
-25 °C to +85 °C
100 °C, max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
31.75x20.32x10.16 mm
16.3 g metal, standard,
14.5 g plastic suffix “P”
Standard, nickel-coated
copper metal
Case material
Dimensions
27.94
31.75
0.5
P3C2405D3
PHI-CON
1
12
bottom view
20.32
24
15.24
13
All dimensions in mm
Tolerance ±0.25 mm
Pin connections
Pin
Standard
Single
Dual
1 +V Input
+V Input
2 N.C.
-V Output
3 N.C.
Common
9 Omitted
Omitted
10 -V Output Common
11 +V Output +V Output
12 -V Input
-V Input
13 -V Input
-V Input
14 +V Output +V Output
15 -V Output Common
16 Omitted
Omitted
22 N.C.
Common
23 N.C.
-V Output
24 +V Input
+V Input
0.5
3.5 kVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output +V Output
Omitted
Omitted
-V Output Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
2.54
10.16
3.05 min.
Life Support Policy: HY-LINE does not authorize
the use of any of its products for use in life support
devices or systems without the express written
approval of an officer of the Company. Life support
systems are devices which support or sustain life,
and whose failure to perform, when properly used
in accordance with instructions for use provided in
the labeling, can be reasonably expected to result
in significant injury to the user. Rev: 5.05 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]