2W DC-DC Converter P2Y-Series ● ● ● ● ● ● ● ● ● ● Wide 4:1 input range Up to 3500 VDC isolation Continuous short circuit protection Low profile metal package available Mobile / battery driven applications Distributed power networks Data communications equipments Telecommunication instruments Process / machine control equipments MTBF >1.03 MHours Model selection guide Typ Input voltage range Output voltage [VDC] [VDC] Single output P2Y243R3S2 9…36 3.3 P2Y2405S2 9…36 5.0 P2Y2409S2 9…36 9.0 P2Y2412S2 9…36 12.0 P2Y2415S2 9…36 15.0 P2Y2418S2 9…36 18.0 P2Y2424S2 9…36 24.0 P2Y483R3S2 18…72 3.3 P2Y4805S2 18…72 5.0 P2Y4809S2 18…72 9.0 P2Y4812S2 18…72 12.0 P2Y4815S2 18…72 15.0 P2Y4818S2 18…72 18.0 P2Y4824S2 18…72 24.0 Dual output P2Y243R3D2 9…36 ±3.3 P2Y2405D2 9…36 ±5.0 P2Y2409D2 9…36 ±9.0 P2Y2412D2 9…36 ±12.0 P2Y2415D2 9…36 ±15.0 P2Y2418D2 9…36 ±18.0 P2Y2424D2 9…36 ±24.0 P2Y483R3D2 18…72 ±3.3 P2Y4805D2 18…72 ±5.0 P2Y4809D2 18…72 ±9.0 P2Y4812D2 18…72 ±12.0 P2Y4815D2 18…72 ±15.0 P2Y4818D2 18…72 ±18.0 P2Y4824D2 18…72 ±24.0 Notes: Suffix “H” 3500 VDC instead of 1500 VDC isolation. Output current [mA] Efficiency typ. [%] 600 400 223 167 134 112 84 600 400 223 167 134 112 84 72 75 76 76 78 77 77 73 76 78 78 77 78 77 ±300 ±200 ±112 ±83 ±67 ±56 ±42 ±300 ±200 ±112 ±83 ±67 ±56 ±42 73 75 78 77 76 77 77 73 76 76 76 76 76 77 Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 2W DC-DC Converter P2Y-Series Specifications Input Voltage range General Efficiency Switching frequency Environmental Operating temperature (ambient) Case temperature Storage temperature Derating Humidity 24 VDC, 9..36 VDC 48 VDC, 18..72 VDC Pi Network Filter Isolation: Rated voltage Resistance Capacitance Output Voltage accuracy Voltage balance (dual outputs) Ripple and noise (at 20 MHz BW) Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient 1500 VDC, Standard 3500 VDC, Suffix “H” 109 Ω 390 pF, typ. ± 1%, max. ± 1% Cooling Physical Dimensions Weight 60 mVp-p, max. Continuous Automatic ± 0.5%, max. ± 0.5%, max. ± 0.02% / °C 72% to 78% 260 kHz, typ. -40 °C to +85 °C 100 °C, max. -40 °C to +125 °C None required Up to 90%, non-condensing Free-air convection 31.75x20.32x10.16 mm 16.3 g metal, standard, 14.5 g plastic suffix “P” Standard, nickel-coated copper metal Case material Dimensions 27.94 31.75 0.5 P2Y2405D2 PHI-CON 1 12 bottom view 20.32 24 15.24 13 All dimensions in mm Tolerance ±0.25 mm Pin connections Pin Standard Single Dual 1 +V Input +V Input 2 N.C. -V Output 3 N.C. Common 9 Omitted Omitted 10 -V Output Common 11 +V Output +V Output 12 -V Input -V Input 13 -V Input -V Input 14 +V Output +V Output 15 -V Output Common 16 Omitted Omitted 22 N.C. Common 23 N.C. -V Output 24 +V Input +V Input 0.5 3.5 kVDC Single Dual Omitted Omitted -V Input -V Input -V Input -V Input Omitted Common Omitted Omitted N.C. -V Output Omitted Omitted Omitted Omitted +V Output +V Output Omitted Omitted -V Output Common +V Input +V Input +V Input +V Input Omitted Omitted 2.54 10.16 3.05 min. Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 5.05 f Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]