Download

5W DC-DC Converter P5Y-Series
●
●
●
●
Wide 4:1input range
Up to 3500 VDC isolation
Continuous short circuit protection
None conductive plastic case
Model selection guide
Typ
Input nominal voltage Output voltage
[VDC]
[VDC]
Output current
[mA]
Efficiency typ.
[%]
Single output
P5Y2405S
9...36
5.0
1000
P5Y2409S
9...36
9.0
556
P5Y2412S
9...36
12.0
417
P5Y2415S
9...36
15.0
333
P5Y2418S
9...36
18.0
278
P5Y2424S
9...36
24.0
209
P5Y4805S
18...72
5.0
1000
P5Y4809S
18...72
9.0
556
P5Y4812S
18...72
12.0
417
P5Y4815S
18...72
15.0
333
P5Y4818S
18...72
18.0
278
P5Y4824S
18...72
24.0
209
Dual output
P5Y2405D
9...36
±5.0
±500
P5Y2409D
9...36
±9.0
±278
P5Y2412D
9...36
±12.0
±208
P5Y2415D
9...36
±15.0
±167
P5Y2418D
9...36
±18.0
±139
P5Y2424D
9...36
±24.0
±104
P5Y4805D
18...72
±5.0
±500
P5Y4809D
18...72
±9.0
±278
P5Y4812D
18...72
±12.0
±208
P5Y4815D
18...72
±15.0
±167
P5Y4818D
18...72
±18.0
±139
P5Y4824D
18...72
±24.0
±104
Input voltage range reach from 4.5V to 72V and the output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
80
80
80
80
80
80
79
80
82
82
82
82
78
80
80
82
82
82
78
79
79
80
80
80
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5Y-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
24 VDC, 9…36 VDC
48 VDC, 18...72 VDC
π (Pi)-Network
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
± 1%, max.
± 1%
60 mVp-p, max.
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
78% to 82%
100 kHz…400 kHz
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 90%,
None condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
31.75x20.32x10.16 mm
17 g plastic standard,
19 g metal suffix “M”
None conductive plastic
Case material
Dimensions
27.94
31.75
0.5
P5Y1205S
PHI-CON
1
12
bottom view
20.32
24
All dimensions in mm
Tolerance ±0.25 mm
15.24
13
0.5
2.54
3.05 min.
10.16
Pin connections
Pin
1
2
10
11
12
13
15
23
24
Life Support Policy: HY-LINE does not
authorize the use of any of its products
for use in life support devices or systems
without the express written approval of
an officer of the Company. Life support
systems are devices which support or
sustain life, and whose failure to perform,
when properly used in accordance with
instructions for use provided in the
labeling, can be reasonably expected to
result in significant injury to the user.
Rev: 2.06 f
1.5kV & 3.5kV version
Single
Dual
+V Input
+V Input
+V Input
+V Input
N.C.
Common
N.C.
Common
-V Output
N.C.
+V Output
-V Output
N.C.
+V Output
-V Input
-V Input
-V Input
-V Input
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz: